In this study, a simple, accurate, precise, and cost-effective method based on reversed-phase high-performance liquid chromatography with diode array detection for the quantification of aceclofenac in a small volume of human serum (100 µL) was developed and validated according to US-FDA guidelines. Acetanilide was used as an internal standard. The analyte and internal standard were spiked in human serum and extracted using a simple protein precipitation technique. The analysis was carried out on a reversed-phase C18 HPLC column (5 μm, 4.6 × 250 mm) using 0.1% formic acid and acetonitrile in a ratio of 40 : 60 (v/v) as the mobile phase with UV detection at 275 nm at a flow rate of 1.2 mL/min. The developed method was found to be sensitive, selective, and linear over the concentration range of 0.8–20 µg/mL with good precision (RSD ≤ 15%) and accuracy (relative error ≤15%). The limit of detection and lower limit of quantification were found to be 0.3 and 0.8 µg/mL, respectively.
Improving the dissolution and solubility of poorly water-soluble drugs remains a major challenge in drug development. Solid dispersion (SD) techniques offer an effective strategy by which to enhance the bioavailability of BCS Class II drugs such as ivermectin (IVM). This study aimed to develop and validate stability-indicating analytical methods for the quantification of IVM and to evaluate the performance of the formulated SDs. A novel RP-HPLC and a UV spectrophotometric method were developed and validated in accordance with ICH guidelines. IVM SDs were prepared via physical mixing (PM), solvent evaporation (SE), and melt fusion (MF) using Poloxamer 188, Kollicoat® IR, and PEG 6000 at respective ratios of 1:1, 1:3, and 1:5. Dissolution studies showed a marked enhancement in drug release from SDs prepared by SE and MF methods compared with pure IVM. Among all formulations, the Poloxamer 188-based binary SD prepared by the SE method at a 1:5 ratio exhibited the highest dissolution (98.55% at 60 min), with release kinetics following anomalous (non-Fickian) transport (n = 0.681) according to the Korsmeyer–Peppas model. Solid-state characterization evidenced by FTIR, DSC, TGA, and SEM confirmed the transformation of IVM from its crystalline form to an amorphous state. Future studies will focus on the in vivo evaluation of the optimized IVM SD formulations.