Isaac Owusu-Mensah

Dr. Isaac Owusu-Mensah

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2024 in European Journal of Pure and Applied Mathematics
Verified
Journal Article
Open access
PDF file
KBKWAME OWUSU BEMPAH
KWAME OWUSU BEMPAH
KGKwasi Baah Gyamfi
Kwasi Baah Gyamfi
FBFrancis Ohene Boateng
Francis Ohene Boateng
IOIsaac Owusu-Mensah
Isaac Owusu-Mensah
Privacy is given top priority as far as communication involving transfer of confidential document or data is concerned. There is therefore a need to keep confidential data secretive from being invaded by unauthorised access, and this is done through cryptography algorithms, where the Advanced Encryption Standard algorithm has been the widely accepted symmetric block encryption algorithm for such purposes. This paper therefore focuses on developing a new AES-512 bits symmetric encryption algorithm through modification of the conventional AES-128 algorithm to be used purposefully in the classroom for document transfer.The development comes with increasing the plaintext bits of the conventional AES-128 algorithm to 512 bits plaintext which undergoes five operational transformations: STATE, SKGF, SRL, SCL and AARC through key size in the Galois field, GF(29). A numerical example is then given to explain the use of the algorithm, and finally, we provide a comparative study of this algorithm and other existing symmetric encryption models, such as the AES-128 and DES algorithms.

30 April 2025 in ChemRxiv
Verified
Preprint
Open access
PDF file
SASumaila Abdul
Sumaila Abdul
BDBismark Dwumfour-Asare
Bismark Dwumfour-Asare
GMGeorge Tetteh Mensah
George Tetteh Mensah
IOIsaac Owusu-Mensah
Isaac Owusu-Mensah
Peri-urban and rural areas in developing countries like Ghana face challenges with access to quality potable water due to increasing groundwater contamination risks. This study assessed the risk of hand-dug well (HDW) water in Aflao using a cross-sectional survey of 400 wells based on WHO sanitary inspection checklists.Water samples from 20 wells were analysed for microbial contamination and heavy metals (Pb, Cd, Cr, Ni, As) using membrane filtration and Atomic Absorption Spectrometry. Results revealed that 37.3% of wells were within 10 meters of latrines, 98% lacked concrete floors, 98.3% lacked covers, 88.5% had poor drainage, 31.8% were under trees, and all were shallow (<30m). Microbial loads exceeded WHO guidelines(0 cfu/100ml): total coliforms (579.7 ± 294.9 CFU/100 ml), faecal coliforms (32.6 ± 54.7 CFU/100 ml), and E. coli (14.7 ± 21.7 CFU/100 ml) were detected in all samples.Sanitary risk factors, including latrine proximity, absence of covers, poor drainage, and shallow depth, were significantly associated with microbial contamination (p1) . Heavy metals were below detection limits (0.001–0.01 mg/l). Poor microbial quality and its association with sanitary risks confirmed that HDWs in Aflao are unsafe for consumption without treatment.