A thermal analysis of a 5 kVA dry-type transformer under linear and non-linear loads conditions is studied in this paper. The main goal here is to calculate the hottest-spot transformer temperature under free convection through the resolution of the heat conduction equation in three dimensions (3D) using COMSOL Multiphysics®. The proposed technique was validated through experimental data obtained in laboratory. The temperature inside the cores was measured under the influence of free convection. The radiation emission was also measured through a thermal camera. The heat transfer coefficient for both conditions was obtained from empirical correlations. The hottest-spot temperatures were determined from the analysis in the commercial software which was used for the numerical simulations of the transformer heating and cooling under some loading conditions. The temperature residuals, that is, the experimental temperature values subtracted by the numerical temperature values, were below 10%. The numerical analysis found that the hottest-spot temperatures in the core reached 20 °C above the transformer insulation limit. The location of the hottest-spot as well as the obtained temperatures can be used to improve more resistant dry-type transformers.
19 July 2016 in International Journal of Emerging Electric Power Systems
This paper aims to evaluate the performance of commercial class A and class S power quality (PQ) instruments when measuring time-varying harmonics. By using a high precision programmable voltage and current source, two meters from different manufacturers are analyzed and compared. Three-phase voltage signals are applied to PQ instruments, considering 3 situations of time-varying harmonic distortions, whose harmonic distortion values are in accordance with typical values found in power systems. This work is relevant considering that international standardization documents do not pay much attention to this aspect of harmonic distortion.
The design of shunt passive filters has been a topic of constant research since the 70’s. Due to the lower cost, passive shunt filters are still considered a preferred option. This paper presents a novel approach for the placement and sizing of passive filters through ranking solutions based on the minimization of the total harmonic distortion (THDV) of the supply system rather than one specific bus, without neglecting the individual harmonic distortions. The developed method was implemented using Matlab/Simulink and applied to a test system. The results shown that is possible to minimize the total voltage harmonic distortion using a system approach during the filter selection. Additionally, since the method is mainly based on a heurist approach, it avoids the complexity associated with of use of advanced mathematical tools such as artificial intelligence techniques. The analyses contemplate a sinusoidal voltage utility and also the condition with background distortion utility.