Ivan Calderon-Cortez

Dr. Ivan Calderon-Cortez

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2024 in Veterinary World
Verified
Journal Article
Open access
DADaniel Alvitez-Temoche
Daniel Alvitez-Temoche
EAElca del Aguila
Elca del Aguila
LGLarza-Valencia Diego Ga
Larza-Valencia Diego Ga
ICIvan Calderon-Cortez
Ivan Calderon-Cortez
FEFran Espinoza-Carhuancho
Fran Espinoza-Carhuancho
FMFrank Mayta-Tovalino
Frank Mayta-Tovalino
Therefore, this study aimed to analyze the academic literature published in veterinary dentistry from 1990 to 2023.

1 October 2026 in Revista Científica Odontológica
Verified
Journal Article
Open access
PDF file
EPElmo Sigifredo Palacios-Alva
Elmo Sigifredo Palacios-Alva
JPJerson J. Palomino-Zorrilla
Jerson J. Palomino-Zorrilla
LSLizardo Augusto Saenz-Quiroz
Lizardo Augusto Saenz-Quiroz
ICIvan Calderon-Cortez
Ivan Calderon-Cortez
OHOlinda Huapaya-Paricoto
Olinda Huapaya-Paricoto
MGMaria Eugenia Guerrero
Maria Eugenia Guerrero
Antecedentes: Se han analizado las diferentes complicaciones asociadas a la anestesia local y sus posibles tratamientos. El odontólogo debe reconocer los síntomas y tener en cuenta que pueden presentarse complicaciones más graves. Este estudio tuvo como objetivo revisar la literatura sobre accidentes y complicaciones relacionadas con la anestesia local dental y proponer una clasificación basada en la profundidad anatómica y la presentación clínica. Materiales y métodos: Se realizó una búsqueda sistemática en PubMed, Web of Science y Scopus hasta junio de 2025. Las palabras clave se basaron en términos MeSH y DeCS relacionados con la anestesia dental y sus complicaciones. Se incluyeron estudios in vivo, informes de casos y series de casos en cirugía oral. Tras revisar 364 registros, 28 estudios cumplieron los criterios de inclusión. Se extrajeron datos sobre las características del estudio, el tipo de anestesia, las complicaciones y el tratamiento. Resultados: Las complicaciones fueron más frecuentes con los bloqueos del nervio alveolar inferior. Los eventos locales incluyeron fracturas por punción, parestesia, hematoma, isquemia, infecciones y trismo. Las complicaciones sistémicas incluyeron síncope, toxicidad, reacciones vasoconstrictoras y alergias. Si bien muchas se resolvieron espontáneamente, otras requirieron intervención quirúrgica o farmacológica. Se propone una nueva clasificación basada en los planos anatómicos afectados (superficial, profundo, neurológico y orbitoocular) y categorías sistémicas, lo que facilita el reconocimiento y el tratamiento. Conclusión: Los anestésicos locales, aunque de uso extendido y generalmente seguros, pueden causar diversas complicaciones en cirugía oral. La clasificación propuesta sistematiza estos eventos y puede mejorar la claridad diagnóstica, las estrategias de prevención y la toma de decisiones clínicas.

1 January 2026 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
DMDeivis Maticorena
Deivis Maticorena
FLFelipe Lozano
Felipe Lozano
CMCesar Mauricio-Vilchez
Cesar Mauricio-Vilchez
BDBerly Delgado-Cumpa
Berly Delgado-Cumpa
FEFran Espinoza-Carhuancho
Fran Espinoza-Carhuancho
FMFrank Mayta-Tovalino
Frank Mayta-Tovalino
Aim: To evaluate the thermal changes occurring during dental preparation for fixed prostheses using infrared thermography and identify the predictive factors influencing temperature rise through a linear regression model. Materials and Methods: An in vitro experimental design was established to use bovine incisors, chosen because their histology is like that of human teeth. The specimens were randomly grouped according to irrigation status (irrigation vs. no irrigation), bur condition (new vs. used), and bur brand (brand A, brand B, brand C), respectively. Dental preparations were performed using high‐speed handpieces (300,000 RPM) with medium‐grain diamond burs providing the source of irrigation at a rate of 50 mL/min. Surface temperature changes were continuously recorded by infrared thermography (Fluke TiS55+) during preparation. Results: Immediately after tooth preparation, temperatures were significantly higher under nonirrigated conditions (36.15°C ± 4.37°C) compared with irrigated procedures (20.78°C ± 0.79°C), yielding an overall mean difference of 15.37°C (95% CI: 14.24–16.51; p < 0.001). Preparations performed with previously used diamond burs generated greater thermal elevations than unused burs (mean difference: −3.24°C; 95% CI: −6.20 to −0.27; p < 0.001). Variations among bur brands were minimal and did not reach statistical significance in post hoc testing ( p > 0.05), although subtle differences emerged in the adjusted regression model. Overall, temperature rise during dental preparation was strongly influenced by irrigation, whereas bur brand exerted negligible impact. Conclusion: Irrigation has been found to be the most significant factor for managing temperature changes associated with tooth preparation, with burs wear also being a contributing factor to thermal accumulation, though less significantly. The brand of bur used in the tooth preparation procedure had the least influence on the amount of thermal accumulation experienced by the tooth.

16 January 2026 in International Journal of Dentistry
Verified
Journal Article
Open access
DADaniel Alvitez-Temoche
Daniel Alvitez-Temoche
FMFranco Mauricio
Franco Mauricio
BDBerly Delgado-Cumpa
Berly Delgado-Cumpa
JMJulia Medina
Julia Medina
FEFran Espinoza-Carhuancho
Fran Espinoza-Carhuancho
FMFrank Mayta-Tovalino
Frank Mayta-Tovalino
Background: Thermographic‐infrared changes during osteotomy surgery depend on the type of motor used, size, and system of the dental implant. This study undertakes the evaluation of these thermal variations for successful optimization of dependent surgical procedures while aiming toward reduced thermal damage to the bone tissue. Methods: An in vitro comparative study was conducted to assess the thermographic‐infrared changes during surgical osteotomy influenced by the motor type, diameter, and dental implant system. The Checklist for Reporting in vitro Studies (CRIS) guidelines were adopted to report the findings. Bones with fractures, structural damage, or anomalies were omitted. The bones were stored at −20°C, then thawed, cleaned, disinfected, and calibrated. The implant motors (Coxo, W&H, Dentflex, and Baby Driller) were calibrated for equal performance. Standardized drilling procedures were followed using initial, pilot, second, and final drills. A Fluke TiS55+ thermographic camera recorded temperature changes every 10 s, being maintained at 30 cm. Results: ANOVA analysis revealed significant differences in temperature variations between the implant systems and drill types ( p = 0.001). The Coxo and Dentflex motors showed higher mean temperatures (26.57 and 27.65°C, respectively) compared to the W&H and Baby Driller (24.45 and 24.65°C, respectively). Regression analysis indicated that baseline ( β = −0.67, p < 0.01), pilot drill ( β = 0.37, p < 0.01), and second drill temperatures ( β = 0.80, p < 0.01) significantly influenced the final drilling temperature. However, the implant system ( p = 0.39) was not a significant predictor of the final temperature. Conclusion: The motor type and implant system have a major effect on the thermal changes that occur during surgical osteotomies. Clinicians should administer motor types and implant systems to minimize thermal damage to the bone; thus, the performance in dental implant surgeries can be improved. Therein, we have patient safety and longevity of dental implants.

1 January 2026 in International Journal of Dentistry
Verified
Journal Article
Open access
FMFrank Mayta-Tovalino
Frank Mayta-Tovalino
FEFran Espinoza-Carhuancho
Fran Espinoza-Carhuancho
DADaniel Alvitez-Temoche
Daniel Alvitez-Temoche
ICIvan Calderon-Cortez
Ivan Calderon-Cortez
MCMiguel Cabanillas-Lazo
Miguel Cabanillas-Lazo
Adrian V. HernandezAdrian V. Hernandez
Adrian V. Hernandez
Background: The choice between cemented and screw‐retained zirconia single crowns remains a matter of debate, especially concerning long‐term biological and prosthetic outcomes. Objective: This systematic review and meta‐analysis aimed to compare the clinical and mechanical performance of cemented versus screw‐retained zirconia single crowns. Methods: An extensive search of PubMed, Embase, Web of Science, and Scopus was performed until July 2025. Only randomized controlled trials (RCTs) that compared cemented to screw‐retained zirconia single crowns were eligible for inclusion. Primary outcomes were marginal bone level (MBL) changes, bleeding on probing (BoP), and plaque index (PI). Secondary outcomes included probing depth (PD), modified PI (MPLI), width of keratinized (KT) mucosa, and mechanical complications (i.e., fracture and loosening). Risk of bias was evaluated using the Cochrane RoB 2.0 tool and certainty of evidence (CoE) was assessed with GRADE methods. Results: Nine RCTs involving 298 patients were included. Cemented zirconia single crowns probably result in a slight reduction in marginal bone loss compared with screw‐retained crowns (mean difference [MD] = –0.04 mm; 95% confidence interval [CI]: –0.08 to –0.00; I 2 = 0%; moderate CoE). Cemented crowns likely result in little to no difference in BoP, PI, PD, MPLI, and width of KT mucosa. Similarly, they likely result in little to no difference in mechanical complications such as fracture (risk ratio [RR] = 0.99; 95% CI: 0.82–1.19) and screw loosening (RR = 0.94; 95% CI: 0.50–1.77). Subgroup analyses confirmed these findings, except for MBL, where cemented crowns probably result in a slight reduction in longer follow‐ups and adult populations. Most included trials presented some concerns or high risk of bias, primarily related to outcome measurement and reporting. Conclusion: Cemented zirconia single crowns may lead to slightly less marginal bone loss than screw‐retained ones, but no meaningful differences were found in other biological or prosthetic complications. Current evidence remains limited, underscoring the need for well‐designed, long‐term RCTs to provide more definitive guidance.

9 June 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
SSebastián Contreras García
Sebastián Contreras García
DADaniel Alvitez-Temoche
Daniel Alvitez-Temoche
FMFranco Mauricio
Franco Mauricio
FEFran Espinoza-Carhuancho
Fran Espinoza-Carhuancho
OSOscar Sotomayor
Oscar Sotomayor
FMFrank Mayta-Tovalino
Frank Mayta-Tovalino
Background: Excessive heat during implant osteotomy adversely affects bone healing and osseointegration. It is essential to carefully study the effects of drill systems, motors, and irrigation methods on intraosseous temperature. We aim to analyze the predictors of intraosseous temperature variation during osteotomy in bovine bone blocks using the Helix GM (Titanium) and Zi Compact (Zirconium) drill systems in conjunction with three different surgical motors and irrigation conditions using a linear regression model. Materials and Methods: An in vitro experimental study was conducted at the Periodontology and Oral Implantology Laboratory of the Universidad Nacional Federico Villarreal. A total of 120 bovine rib bone blocks (1.5 cm) were prepared using a standardized osteotomy protocol involving lance drills and ∅ 2 mm and ∅ 3 mm helical drills from the Zi and Helix GM compact kits (Neodent, Curitiba, Brazil). Irrigation was performed with chlorhexidine 0.12% + CPC 0.05% at ambient temperature (21 °C). Osteotomies were executed with two surgical motors (Coxo and Driller) at 1200 rpm and 35 Ncm torque. The intraosseous temperature was recorded in real time via a calibrated Fluke TiS55+ (Fluke, Everett, WA, USA) infrared thermographic camera and validated using a probe thermometer. Statistical analyses used Stata 17, applying descriptive measures, t-tests, and linear regression at 95% confidence for reliability. Results: Osteotomies without irrigation consistently resulted in slightly higher intraosseous temperatures. The Helix GM system, with the ∅ 3 mm drill and Driller motor, produced a final temperature of 29.3 °C ± 2.0. The Zi system with the lance drill and drill motor produced a maximum temperature of 32.7 °C ± 2.3. Irrigation was successful, and the elevated temperatures after irrigation were close to the surgical room temperature of 21–23 °C. Linear regression analysis showed that the drill motor produced a statistically significant decrease in temperature (−2.29 °C; 95% CI: −4.36 to −0.21; p = 0.031) while the lance drill with no additional irrigation produced a statistically significant increase in temperature (0.24 °C; 95% CI: 0.06 to 0.42; p = 0.009). Conclusions: The absence of irrigation during osteotomy significantly increased the intraosseous temperature, potentially compromising bone integrity. The use of irrigation, especially with the Driller motor, demonstrates a protective thermal effect.