Sublobar pulmonary resection has become an increasingly adopted approach for early-stage non-small cell lung cancer, driven by evidence that anatomical segmentectomy can achieve oncological outcomes comparable to lobectomy in selected patients. Safe execution of sublobar resection depends on accurate preoperative identification of segmental bronchovascular anatomy, which demonstrates substantial variability. Conventional two-dimensional (2D) computed tomography (CT) imposes significant limitations on anatomical interpretation, particularly at the segmental and subsegmental level. Three-dimensional (3D) bronchovascular modelling provides patient-specific representations of segmental anatomy and relationships that address these limitations. This narrative review examines the current and emerging roles of 3D modelling in personalised thoracic surgery. It discusses the anatomical basis for its application, the limitations of conventional imaging, and the contribution of 3D modelling to preoperative planning and intraoperative decision making. It also considers broader applications, current limitations, and future directions, with emphasis on how patient-specific 3D modelling can support more tailored operative strategies and more individualised surgical care.
Background: The ”respect” approach to surgical mitral valve repair, which involves implanting artificial neochordae, is gaining increased adoption. Surgeons are possibly prone to error in the manual construction of neochordae, which can lead to prolonged cross-clamp times. Novel systems such as Chord-X Pre-Measured Loops (On-X Life Technologies, Inc., Austin, TX, USA) eliminate the need for manual neochordae construction, potentially simplifying the mitral repair procedure. However, clinical data on its use are currently limited to a small publication. Methods: We conducted a retrospective cohort study to evaluate the use of Chord-X loops in 40 consecutive patients who underwent surgery in Geelong, Victoria, Australia, between May 2020 and February 2024. Three surgeons participated in this study. Results: All patients were referred for severe mitral valve regurgitation secondary to myxomatous degeneration, with P2 prolapse being the most common pathology. Chord-X Pre-Measured Loops effectively corrected a variety of leaflet pathologies, including bi-leaflet disease, with a single set of loops sufficing in most patients. Intraoperative and follow-up echocardiographic assessments revealed no greater than mild mitral regurgitation in any patient, with 75% exhibiting no or trace mitral regurgitation. Conclusions: The Chord-X Pre-Measured Loops system demonstrated safety, efficacy, and reproducibility across all patients. Surgeons were able to easily adopt this technology without requiring additional training. We believe this technology offers a safe option for surgeons performing low-volume mitral repair surgeries.