Boxuan Huang

Dr. Boxuan Huang


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
ASAnjie Shen
Anjie Shen
BHBoxuan Huang
Boxuan Huang
HBHang Bao
Hang Bao
TZTeng Zhang
Teng Zhang
KZKaijun Zhang
Kaijun Zhang
WHWei Han
Wei Han
Background: Traditional high-speed mechanical osteotomes cause substantial thermal and mechanical trauma, impairing bone healing. Erbium-doped yttrium-aluminum-garnet (Er:YAG) lasers, with water-mediated non-contact ablation, offer precise osteotomy potential with minimal collateral damage. This study demonstrated the feasibility of Er:YAG laser use for complex osteotomies and elucidated its multi-scale biological impacts on bone. Methods: A custom Er:YAG laser performed Z/arc-shaped osteotomies on fresh ovine bone (oscillating saw as control); paired rat tibial osteotomies; and compared laser vs. saw resection. Osteotomy surfaces were characterized by SEM/micro-CT; histological staining quantified thermal/mechanical damage. Bone marrow-derived mesenchymal stem cell (BMSC) adhesion, viability, and infiltration on cut surfaces were evaluated via LSCM. Result: In the ex vivo ovine model, the Er:YAG laser enabled precise execution of complex osteotomies (Z-shaped and arc-shaped), producing significantly narrower gaps than the oscillating saw (1.14 mm vs. 2.70 mm, p < 0.001) with high geometric fidelity and smooth surfaces free of burrs, micro-cracks, or debris. In the in vivo rat model, laser ablation simultaneously minimized both thermal and mechanical damage at the osteotomy interface: it reduced the thermal damage depth (154 vs. 592 µm, p < 0.001) and empty lacunae rate (16.8% vs. 41.8%, p < 0.001) while completely avoiding the mechanical damage zone (297 µm) induced by sawing. Furthermore, the laser-ablated surface established a highly bioactive interface, which significantly enhanced the adhesion (606 vs. 389 cells), viability (86.9% vs. 46.6%), and infiltration depth (196 vs. 75 µm) of bone marrow-derived mesenchymal stem cells (all p < 0.001). Conclusions: In conclusion, this proof-of-concept study demonstrates that the Er:YAG laser has the potential to enable precise bone resection while preserving microstructure. By establishing a pro-regenerative microenvironment, this technology shows promise as a biologically favorable alternative to conventional sawing, although further technical refinement and long-term validation are essential for its clinical translation.