To assess the technical feasibility and safety of image-guided percutaneous biphasic monopolar pulsed electric field (PEF) ablation of primary and metastatic tumors. With IRB approval and HIPAA compliance, this retrospective, single-institution study cohort of 17 patients (mean age: 53.5 years, range: 20 - 94 years) with overall progressive disease underwent 26 PEF ablation procedures for 30 metastatic (90%) and primary (10%) target lesions in the thorax (n=20), abdomen (n=7), and head and neck (n=3). Concurrent systemic therapy was used in 14/17 patients (82%). Follow-up imaging was scheduled for 1, 3, and 6 months after PEF ablation, and target and off-target lesion sizes were recorded. The overall response was assessed by the RECIST 1.1 criteria with imaging immediately before PEF serving as baseline. Adverse events (AEs) were determined by the Society of Interventional Radiology classification. PEF ablation procedures were well tolerated and technically feasible for all 17 of 17 patients. The mean initial size of the target and off-target tumors were 2.6±1.5 cm (range: 0.4 - 6.9cm) and 2.2±1.1 cm (range: 1.0 - 5.2cm), respectively. Overall, 15/30 (50%) target lesions and 12/24 (50%) off-target lesions were unchanged or decreased in size at the patient's last follow-up. Eight patients had overall stable disease (47%) at the last follow-up. There were nine mild (9/26, 35%) and one moderate (1/26, 4%) AE. All PEF procedures were technically feasible with one moderate AE and stable disease for 47% of patients with a median follow-up period of three months.
8 November 2022 in Journal of Vascular and Interventional Radiology
To evaluate the efficacy of combination therapy using transarterial chemoembolization with microwave ablation (MWA) therapy vs. MWA monotherapy for hepatocellular carcinomas (HCCs) >3 cm in size. This two-arm retrospective observational study included patients with HCCs >3 cm who underwent either combination therapy (29 patients) or MWA monotherapy (35 patients) between 2014 and 2020. The treatment outcomes related to primary treatment efficacy, local tumor progression (LTP), tumor control rate, and overall survival were compared between each cohort. The technical success and primary efficacy were 96.56% and 100.00% in the combination therapy cohort, and 91.42% and 100.00% in the MWA cohort, respectively, over a mean follow-up period of 27.6 months. The 1- and 3-year rates of LTP-free survival were 78.57% and 69.56% in the combination therapy cohort, vs. 72.45% and 35.44% in the MWA cohort, respectively (P = 0.001). The overall progression-free survival was longer in the combination therapy cohort compared with the MWA cohort (median: 56.0 vs. 13.0 months; P = 0.017). With the incorporation of additional locoregional therapy, the overall survival rates were not significantly different, with 1- and 3-year overall survival rates of 100.00% and 88.71% in the combination therapy cohort and rates of 90.15% and 82.76% in the MWA cohort, respectively (P = 0.235). The combination therapy provided significantly longer upfront LTP-free survival in HCCs >3 cm when compared with the MWA treatment alone, albeit with similar local tumor control and overall survival rates when accounting for additional locoregional therapies.
1 May 2018 in Journal of Vascular and Interventional Radiology
Background: The purpose of this study was to evaluate and compare the clinical effectiveness and costs of using the Caterpillar Arterial Embolization Device (Caterpillar) and fibered coils in arterial embolization cases. Methods: In this multicenter retrospective study, demographic, laboratory, and procedural data were collected on a total of 48 patients between February 2020 and September 2020. Data were collected on 16 Caterpillar placements and matched with 32 controls who underwent coil embolization of the same vessel with a similar size. Clinical and procedural outcomes including type and size of vessels, time to vessel occlusion, fluoroscopy time, total procedure time, and costs were analyzed and compared. Results: Relative time to occlusion was significantly decreased in the Caterpillar group compared to the controls (57 ± 34 s vs. 11 min 44 s ± 8 min 13 s, p = 0.00001611). Fluoroscopy time (6.9 ± 15 min vs. 19.2 ± 14, p = 0.017) and total procedure time (81.0 ± 36 min vs. 111.5 ± 49 min, p = 0.015) were significantly reduced compared to the coil group. Lastly, overall cost of embolic materials was 1050 ± 0 USD for the Caterpillar group compared to 2312.75 ± 1382.84 USD in the coil group (p = 0.000532). Conclusion: The Caterpillar embolic devices appear safe and effective in arterial occlusion. Compared to fibered coils, the Caterpillar device results in decreased time to vessel occlusion, decreased fluoroscopy and procedural time, and decreased costs, making the Caterpillar an appealing choice for arterial embolization.
Seven patients underwent microwave ablation of hepatic tumors, using hepatic nerve plexus block. Mean visual analog score (VAS; pain on 1-10 scale) was 0.3±0.5 at baseline and 2.5±1.4, 2.6±1.4, and...