Ally Xue

Dr. Ally Xue


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in The Ocular Surface
Verified
Journal Article
Open access
AXAlly Xue
Ally Xue
MWMichael T.M. Wang
Michael T.M. Wang
SOSusan E. Ormonde
Susan E. Ormonde
Jennifer P CraigJennifer P Craig
Jennifer P Craig
To assess long-term cumulative treatment effects of intense pulsed light (IPL) therapy in meibomian gland dysfunction (MGD). Eighty-seven symptomatic participants (58 female, mean ± SD age, 53 ± 16 years) with clinical signs of MGD were enrolled in a prospective, double-masked, parallel-group, randomised, placebo-controlled trial. Participants were randomised to receive either four or five homogeneously sequenced light pulses or placebo treatment to both eyes, (E-Eye Intense Regulated Pulsed Light, E-Swin, France). Visual acuity, dry eye symptomology, tear film parameters, and ocular surface characteristics were assessed immediately before treatment on days 0, 15, 45, 75, and four weeks after treatment course completion on day 105. Inflammatory and goblet cell function marker expression, and eyelid swab microbiology cultures were evaluated at baseline and day 105. Significant decreases in OSDI, SPEED, and SANDE symptomology scores, and meibomian gland capping, accompanied by increased tear film lipid layer thickness, and inhibited Corynebacterium macginleyi growth were observed in both treatment groups (all p < 0.05). Sustained clinical improvements occurred in both treatment groups from day 75, although significant changes from day 45, in lipid layer quality, meibomian gland capping, OSDI and SANDE symptomology, were limited to the five-flash group (all p < 0.05). IPL therapy effected significant improvements in dry eye symptomology, tear film lipid layer thickness, and meibomian gland capping in MGD patients. Five-flash IPL treatment showed superior clinical efficacy to four-flash, and an initial course of at least four treatments is suggested to allow for establishment of sustained cumulative therapeutic benefits prior to evaluation of overall treatment efficacy. ACTRN12616000667415.

20 April 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AXAlly Xue
Ally Xue
ABAlexis Ceecee Britten-Jones
Alexis Ceecee Britten-Jones
DZDian Zhuang
Dian Zhuang
CJCatherine Jennings
Catherine Jennings
AMAlex Müntz
Alex Müntz
Jennifer P CraigJennifer P Craig
Jennifer P Craig
Background: Corneal sensitivity is a key indicator of ocular surface health. This prospective, cross-sectional study evaluated agreement between corneal sensitivity thresholds obtained from equivalent stimulus settings on a contemporary, enhanced dual-temperature non-contact corneal aesthesiometer (NCCA) and a previously validated (standard) device. Methods: Central corneal sensitivity thresholds were measured in the right eyes of healthy participants using both devices. Participants with previous ocular surgery, laser treatment, trauma, contact lens wear, diabetes, or peripheral neuropathy were excluded. Sensitivity thresholds were determined using a forced-response, double-staircase protocol. Inter-device agreement was assessed using Bland–Altman analysis, and consistency was assessed using intraclass correlation coefficients. Results: Median corneal sensitivity thresholds in 51 healthy participants (32 female, 19 male; mean age: 33 ± 14 years) did not differ between enhanced (0.23 [0.18 to 0.38]) and standard (0.25 [0.15 to 0.35]) NCCA instruments (p = 0.73). Bland–Altman analysis demonstrated moderate inter-device agreement, with a mean difference of −0.01 mbar (95% limits of agreement: −0.41 to 0.39 mbar). Linear regression analysis identified greater measurement discrepancies at higher thresholds (p < 0.05), indicating greater variability in individuals with reduced corneal sensitivity. Conclusions: The enhanced NCCA yields reliable corneal sensitivity measures for a room-temperature stimulus and acceptable agreement with the existing (standard) model.