Pia Sjöberg

Dr. Pia Sjöberg

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2018 in European Radiology
Verified
Journal Article
Open access
PDF file
PSPia Sjöberg
Pia Sjöberg
SBSebastian Bidhult
Sebastian Bidhult
JBJelena Bock
Jelena Bock
EHEinar Heiberg
Einar Heiberg
HAHåkan Arheden
Håkan Arheden
MCMarcus Carlsson
Marcus Carlsson
Objectives Indications for pulmonary valve replacement (PVR) in patients with pulmonary regurgitation (PR) after repaired tetralogy of Fallot (rToF) are debated. We aimed to compare right (RV) and left ventricular (LV) kinetic energy (KE) measured by 4D-flow magnetic resonance imaging (MRI) in patients to controls, to further understand the pathophysiological effects of PR. Methods Fifteen patients with rToF with PR > 20% and 14 controls underwent MRI. Ventricular volumes and KE were quantified from cine MRI and 4D-flow, respectively. Lagrangian coherent structures were used to discriminate KE in the PR. Restrictive RV physiology was defined as end-diastolic forward flow. Results LV systolic peak KE was lower in rToF, 2.8 ± 1.1 mJ, compared to healthy volunteers, 4.8 ± 1.1 mJ, p < 0.0001. RV diastolic peak KE was higher in rToF (7.7 ± 4.3 mJ vs 3.1 ± 1.3 mJ, p = 0.0001) and the difference most pronounced in patients with non-restrictive RV physiology. KE was primarily located in the PR volume at the time of diastolic peak KE, 64 ± 17%. Conclusion This is the first study showing disturbed KE in patients with rToF and PR, in both the RV and LV. The role of KE as a potential early marker of ventricular dysfunction to guide intervention needs to be addressed in future studies. Key Points • Kinetic energy (KE) reflects ventricular performance • KE is a potential marker of ventricular dysfunction in Fallot patients • KE is disturbed in both ventricles in patients with tetralogy of Fallot • KE contributes to the understanding of the pathophysiology of pulmonary regurgitation • Lagrangian coherent structures enable differentiation of ventricular inflows

1 December 2018 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
PSPia Sjöberg
Pia Sjöberg
JTJohannes Töger
Johannes Töger
EHErik Hedström
Erik Hedström
PAPer Martin Arvidsson
Per Martin Arvidsson
EHEinar Heiberg
Einar Heiberg
MCMarcus Carlsson
Marcus Carlsson
Intracardiac hemodynamic forces have been proposed to influence remodeling and be a marker of ventricular dysfunction. We aimed to quantify the hemodynamic forces in patients with repaired tetralogy of Fallot (rToF) to further understand the pathophysiological mechanisms as this could be a potential marker for pulmonary valve replacement (PVR) in these patients. Patients with rToF and pulmonary regurgitation (PR) > 20% ( n = 18) and healthy control subjects ( n = 15) underwent MRI, including four-dimensional flow. A subset of patients ( n = 8) underwent PVR and MRI after surgery. Time-resolved hemodynamic forces were quantified using 4D-flow data and indexed to ventricular volume. Patients had higher systolic and diastolic left ventricular (LV) hemodynamic forces compared with control subjects in the lateral-septal/LV outflow tract ( P = 0.011 and P = 0.0031) and inferior-anterior ( P < 0.0001 and P < 0.0001) directions, which are forces not aligned with blood flow. Forces did not change after PVR. Patients had higher RV diastolic forces compared with control subjects in the diaphragm-right ventricular (RV) outflow tract (RVOT; P < 0.001) and apical-basal ( P = 0.0017) directions. After PVR, RV systolic forces in the diaphragm-RVOT direction decreased ( P = 0.039) to lower levels than in control subjects ( P = 0.0064). RV diastolic forces decreased in all directions ( P = 0.0078, P = 0.0078, and P = 0.039) but were still higher than in control subjects in the diaphragm-RVOT direction ( P = 0.046). In conclusion, patients with rToF and PR had LV hemodynamic forces less aligned with intraventricular blood flow compared with control subjects and higher diastolic RV forces along the regurgitant flow direction in the RVOT and that of tricuspid inflow. Remaining force differences in the LV and RV after PVR suggest that biventricular pumping does not normalize after surgery. NEW & NOTEWORTHY Biventricular hemodynamic forces in patients with repaired tetralogy of Fallot and pulmonary regurgitation were quantified for the first time. Left ventricular hemodynamic forces were less aligned to the main blood flow direction in patients compared with control subjects. Higher right ventricular forces were seen along the pulmonary regurgitant and tricuspid inflow directions. Differences in forces versus control subjects remain after pulmonary valve replacement, suggesting that altered biventricular pumping does not normalize after surgery.

14 June 2021 in Clinical Physiology and Functional Imaging
Verified
Journal Article
Open access
PDF file
PSPia Sjöberg
Pia Sjöberg
FSFelicia Seemann
Felicia Seemann
HAHåkan Arheden
Håkan Arheden
EHEinar Heiberg
Einar Heiberg
Non‐invasive quantification of pressure‐volume (PV) loops from brachial pressure and cardiovascular magnetic resonance is a validated method but its application has been limited to resting heart rates. The aim of this study was to improve the previous method and validate it against invasive left‐ventricular pressure measurements in an experimental porcine model, and further apply it to 16 healthy humans at rest and during dobutamine stress. In addition, the improved method calculates the arterial elastance which provides the computation of the ratio of effective arterial (Ea) to maximal ventricular elastance (Emax) representing the ventricular‐arterial coupling. In the porcine model, the differences between the improved non‐invasively derived PV loops and invasively measured PV loops were for stroke work (mean ± SD) 0.00 ± 0.03 J, ventricular efficiency −1.1 ± 0.4%, and contractility 1.1 ± 0.1 mmHg/ml. In human subjects during dobutamine stress, stroke work increased from 1.3 ± 0.3 to 1.7 ± 0.4 J, ventricular efficiency from 71 ± 4 to 82 ± 4%, contractility from 1.3 ± 0.2 to 2.3 ± 0.6 mmHg/ml, and the ratio of arterial to ventricular elastance decreased from 0.96 to 0.56. The improved method for non‐invasive PV loops constitutes a more robust diagnostic tool for cardiac disease states in a wider range of study cohorts at both rest and during stress.

21 June 2022 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PSPia Sjöberg
Pia Sjöberg
EHErik Hedström
Erik Hedström
KFKatrin Fricke
Katrin Fricke
PFPetter Frieberg
Petter Frieberg
CWConstance G Weismann
Constance G Weismann
JTJohannes Töger
Johannes Töger
Background: Neonates with critical congenital heart disease require early intervention. Four‐dimensional (4D) flow may facilitate surgical planning and improve outcome, but accuracy and precision in neonates are unknown.Purpose: To 1) validate two‐dimensional (2D) and 4D flow MRI in a phantom and investigate the effect of spatial and temporal resolution; 2) investigate accuracy and precision of 4D flow and internal consistency of 2D and 4D flow in neonates; and 3) compare scan time of 4D flow to multiple 2D flows.Study Type: Phantom and prospective patients.Population: A total of 17 neonates with surgically corrected aortic coarctation (age 18 days [IQR 11–20]) and a three‐dimensional printed neonatal aorta phantom.Field Strength/Sequence: 1.5T, 2D flow and 4D flow.Assessment: In the phantom, 2D and 4D flow volumes (ascending and descending aorta, and aortic arch vessels) with different resolutions were compared to high‐resolution reference 2D flow. In neonates, 4D flow was compared to 2D flow volumes at each vessel. Internal consistency was computed as the flow volume in the ascending aorta minus the sum of flow volumes in the aortic arch vessels and descending aorta, divided by ascending aortic flow.Statistical tests: Bland–Altman plots, Pearson correlation coefficient (r), and Student's t‐tests.Results: In the phantom, 2D flow differed by 0.01 ± 0.02 liter/min with 1.5 mm spatial resolution and −0.01 ± 0.02 liter/min with 0.8 mm resolution; 4D flow differed by −0.05 ± 0.02 liter/min with 2.4 mm spatial and 42 msec temporal resolution, −0.01 ± 0.02 liter/min with 1.5 mm, 42 msec resolution and −0.01 ± 0.02 liter/min with 1.5 mm, 21 msec resolution. In patients, 4D flow and 2D flow differed by −0.06 ± 0.08 liter/min. Internal consistency in patients was −11% ± 17% for 2D flow and 5% ± 13% for 4D flow. Scan time was 17.1 minutes [IQR 15.5–18.5] for 2D flow and 6.2 minutes [IQR 5.3–6.9] for 4D flow, P < 0.0001.Data Conclusion: Neonatal 4D flow MRI is time efficient and can be acquired with good internal consistency without contrast agents or general anesthesia, thus potentially expanding 4D flow use to the youngest and smallest patients.Evidence Level: 1Technical Efficacy: Stage 2

15 April 2019 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
HGHenrik Guné
Henrik Guné
JSJohan Sjögren
Johan Sjögren
MCMarcus Carlsson
Marcus Carlsson
RGRonny Gustafsson
Ronny Gustafsson
PSPia Sjöberg
Pia Sjöberg
SNShahab Nozohoor
Shahab Nozohoor
To evaluate the potential for right ventricular reverse remodelling after pulmonary valve replacement using cardiac magnetic resonance imaging, in adults with corrected tetralogy of Fallot and severe pulmonary insufficiency. Ten patients with previous correction of tetralogy of Fallot with severe pulmonary insufficiency accepted for pulmonary valve replacement were evaluated prospectively with cardiac magnetic resonance imaging preoperatively and re-evaluated 10 ± 5 months postoperatively. Follow up for survival was 100% complete with mean of 37 ± 12 months. The preoperative mean indexed right ventricular end-diastolic volume was reduced from 161 ± 33 ml/m2 to 120 ± 23 ml/m2 postoperatively, p < 0.001. The preoperative mean indexed right ventricular stroke volume was reduced from 72 ± 20 ml/m2 to 50 ± 6 ml/m2 postoperatively, p = 0.002. After pulmonary valve replacement, the right ventricular ejection fraction did not change significantly (46% versus 42%, p = 0.337). Pulmonary insufficiency fraction decreased from 49% ± 11 to 1% ± 1 postoperatively, p < 0.001. Pulmonary valve replacement leads to a favourable early reverse remodelling with a reduction in RV volumes and improved function in all patients regardless of their preoperative indexed right ventricular volume.

1 February 2020 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
PSPia Sjöberg
Pia Sjöberg
EOEllen Ostenfeld
Ellen Ostenfeld
EHErik Hedström
Erik Hedström
HAHåkan Arheden
Håkan Arheden
RGRonny Gustafsson
Ronny Gustafsson
MCMarcus Carlsson
Marcus Carlsson
Timing and indication for pulmonary valve replacement (PVR) in patients with repaired Tetralogy of Fallot (rToF) and pulmonary regurgitation (PR) are uncertain. To improve understanding of pumping mechanics, we investigated atrioventricular coupling before and after surgical PVR. Cardiovascular magnetic resonance was performed in patients ( n = 12) with rToF and PR > 35% before and after PVR and in healthy controls ( n = 15). Atrioventricular plane displacement (AVPD), global longitudinal peak systolic strain (GLS), atrial and ventricular volumes, and caval blood flows were analyzed. Right ventricular (RV) AVPD and RV free wall GLS were lower in patients before PVR compared with controls ( P < 0.0001; P < 0.01) and decreased after PVR ( P < 0.0001 for both). Left ventricular AVPD was lower in patients before PVR compared with controls ( P < 0.05) and decreased after PVR ( P < 0.01). Left ventricular GLS did not differ between patients and controls ( P > 0.05). Right atrial reservoir volume and RV stroke volume generated by AVPD correlated in controls ( r = 0.93; P < 0.0001) and patients before PVR ( r = 0.88; P < 0.001) but not after PVR. In conclusion, there is a clear atrioventricular coupling in patients before PVR that is lost after PVR, possibly because of loss of pericardial integrity. Impaired atrioventricular coupling complicates assessment of ventricular function after surgery using measurements of longitudinal function. Changes in atrioventricular coupling seen in patients with rToF may be energetically unfavorable, and long-term effects of surgery on atrioventricular coupling is therefore of interest. Also, AVPD and GLS cannot be used interchangeably to assess longitudinal function in rToF. NEW & NOTEWORTHY There is a clear atrioventricular coupling in patients with Tetralogy of Fallot (ToF) and pulmonary regurgitation before surgical pulmonary valve replacement (PVR) that is lost after operation, possibly because of loss of pericardial integrity. The impaired atrioventricular coupling complicates assessment of ventricular function after surgery when using measurements of longitudinal function. Left ventricular atrioventricular plane displacement (AVPD) found differences between patients and controls and changes after PVR that longitudinal strain could not detect. This indicates that AVPD and strain cannot be used interchangeably to assess longitudinal function in repaired ToF.