Hao Zeng

Dr. Hao Zeng


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2024 in Metabolism
Verified
Journal Article
Closed access
SXShilei Xu
Shilei Xu
KDKe-Qiong Deng
Ke-Qiong Deng
CLChengbo Lu
Chengbo Lu
XFXin Fu
Xin Fu
QZQingmei Zhu
Qingmei Zhu
ZLZhibing Lu
Zhibing Lu

1 February 2018 in Chemical Engineering Journal
Verified
Journal Article
Closed access
JRJiabing Ran
Jiabing Ran
HZHao Zeng
Hao Zeng
JCJing Cai
Jing Cai
PJPei Jiang
Pei Jiang
PYPan Yan
Pan Yan
HTHua Tong
Hua Tong

27 March 2020 in Biofabrication
Verified
Journal Article
Closed access
PDF file
HZHao Zeng
Hao Zeng
JPJanak L. Pathak
Janak L. Pathak
YSYusheng Shi
Yusheng Shi
JRJiabing Ran
Jiabing Ran
LLLiang Liang
Liang Liang
YBYi Bai
Yi Bai
The fabrication technique determines the physicochemical and biological properties of scaffolds, including the porosity, mechanical strength, osteoconductivity, and bone regenerative potential. Biphasic calcium phosphate (BCP)-based scaffolds are superior in bone tissue engineering due to their suitable physicochemical and biological properties. We developed an indirect selective laser sintering (SLS) printing strategy to fabricate 3D microporous BCP scaffolds for bone tissue engineering purposes. The green part of the BCP scaffold was fabricated by SLS at a relevant low temperature in the presence of epoxy resin (EP), and the remaining EP was decomposed and eliminated by a subsequent sintering process to obtain the microporous BCP scaffolds. Physicochemical properties, cell adhesion, biocompatibility, in vitro osteogenic potential, and rabbit critical-size cranial bone defect healing potential of the scaffolds were extensively evaluated. This indirect SLS printing eliminated the drawbacks of conventional direct SLS printing at high working temperatures, i.e. wavy deformation of the scaffold, hydroxyapatite decomposition, and conversion of β -tricalcium phosphate (TCP) to α -TCP. Among the scaffolds printed with various binder ratios (by weight) of BCP and EP, the scaffold with 50/50 binder ratio (S4) showed the highest mechanical strength and porosity with the smallest pore size. Scaffold S4 showed the highest effect on osteogenic differentiation of precursor cells in vitro , and this effect was ERK1/2 signaling-dependent. Scaffold S4 robustly promoted precursor cell homing, endogenous bone regeneration, and vascularization in rabbit critical-size cranial defects. In conclusion, BCP scaffolds fabricated by indirect SLS printing maintain the physicochemical properties of BCP and possess the capacity to recruit host precursor cells to the defect site and promote endogenous bone regeneration possibly via the activation of ERK1/2 signaling.

21 November 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
SYSha You
Sha You
FYFan Yu
Fan Yu
QFQihang Fan
Qihang Fan
TXTing Xia
Ting Xia
LLLiang Liang
Liang Liang
BSBin Shi
Bin Shi
Background: Atelocollagen (AC) is a low-immunogenic collagen derivative with longer degradation time, which can be a suitable material for alveolar ridge preservation (ARP). However, there are few human studies on AC using for ARP. This research aims to radiographically evaluate the efficacy of AC in comparison to deproteinized bovine bone minerals covered with a collagen membrane (DBBM/CM) in ARP. Methods: Medical records in the Implantology Department of the Hospital of Stomatology of Wuhan University were screened for patients who received flapless ARP using either AC or DBBM/CM. A total of 58 patients were included in this retrospective study. 28 patients were treated with AC, while 30 patients were used DBBM/CM. Cone-beam computed tomography (CBCT) scans were taken before extraction and after 6 months of healing. To assess the dimensional change of the extraction sockets, the scanning data were output and transferred to the digital software to measure horizontal bone width change, vertical bone height change and bone volume change in region of interest. To evaluate the bone quality of healed sockets, the bone density of virtual implants was evaluated. Results: The horizontal bone width changes at all five different levels showed no significant difference between the two groups. The largest horizontal bone width decrement in both groups occurred at the crest of ridge, which decreased 3.71 ± 1.67 mm in AC group and 3.53 ± 1.51 mm in DBBM/CM group (p = 0.68). At the central buccal aspect, the ridge height reduced 0.10 ± 1.30 mm in AC group, while increased 0.77 ± 2.43 mm in DBBM/CM group (p = 0.10). The vertical bone height differences between two groups showed no statistical significance. The percentages of volume absorption in AC group and DBBM/CM group were 12.37%±6.09% and 14.54%±11.21%, respectively. No significant difference in volume absorption was found (p = 0.36). The average bone density around virtual implants in AC group (649.41 ± 184.71 HU) was significantly lower than that in DBBM/CM group (985.23 ± 207.85 HU) (p < 0.001). Conclusions: ARP with AC had a similar effect on limiting the dimensional alteration of alveolar ridge, when radiographically compared with DBBM/CM.

16 October 2017 in Biomacromolecules
Verified
Journal Article
Closed access
JRJiabing Ran
Jiabing Ran
HZHao Zeng
Hao Zeng
JPJanak Lal Pathak
Janak Lal Pathak
PJPei Jiang
Pei Jiang
YBYi Bai
Yi Bai
BSBin Shi
Bin Shi

14 May 2026 in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
Verified
Journal Article
Closed access
JAJun Ai
Jun Ai
YQYun Qiu
Yun Qiu
YLYongjun Li
Yongjun Li
TXTing Xia
Ting Xia
RMRichard J Miron
Richard J Miron
HZHao Zeng
Hao Zeng