Triggering quakes in a geothermal space: Enhanced geothermal systems (EGSs) provide a potentially clean and abundant energy source. However, two magnitude-5 earthquakes recently occurred in South Korea during EGS site development. Grigoli et al. and Kim et al. present seismic and geophysical evidence that may implicate the second of these earthquakes, which occurred in Pohang, as an induced event. The combination of data from a local seismometer network, well logs, satellite observations, teleseismic waveform analysis, and stress modeling leads to the assessment that the earthquake was probably or almost certainly anthropogenically induced. The possibility remains that the earthquake occurred coincidentally at the EGS site location, but the aftershock distribution and other lines of evidence are concerning for future development of this geothermal resource. Science , this issue p. 1003 , p. 1007
Due to the deep socioeconomic implications, induced seismicity is a timely and increasingly relevant topic of interest for the general public. Cases of induced seismicity have a global distribution and involve a large number of industrial operations, with many documented cases from as far back to the beginning of the twentieth century. However, the sparse and fragmented documentation available makes it difficult to have a clear picture on our understanding of the physical phenomenon and consequently in our ability to mitigate the risk associated with induced seismicity. This review presents a unified and concise summary of the still open questions related to monitoring, discrimination, and management of induced seismicity in the European context and, when possible, provides potential answers. We further discuss selected critical European cases of induced seismicity, which led to the suspension or reduction of the related industrial activities.
1 July 2013 in Journal of Petroleum Science and Engineering
In the light of current concerns related to induced seismicity associated with geological carbon sequestration (GCS), this paper summarizes lessons learned from recent modeling studies on fault activation, induced seismicity, and potential for leakage associated with deep underground carbon dioxide (CO2) injection. Model simulations demonstrate that seismic events large enough to be felt by humans require brittle fault properties and continuous fault permeability allowing pressure to be distributed over a large fault patch to be ruptured at once. Heterogeneous fault properties, which are commonly encountered in faults intersecting multilayered shale/sandstone sequences, effectively reduce the likelihood of inducing felt seismicity and also effectively impede upward CO2 leakage. A number of simulations show that even a sizable seismic event that could be felt may not be capable of opening a new flow path across the entire thickness of an overlying caprock and it is very unlikely to cross a system of multiple overlying caprock units. Site-specific model simulations of the In Salah CO2 storage demonstration site showed that deep fractured zone responses and associated microseismicity occurred in the brittle fractured sandstone reservoir, but at a very substantial reservoir overpressure close to the magnitude of the least principal stress. We conclude by emphasizing the importance of site investigation to characterize rock properties and if at all possible to avoid brittle rock such as proximity of crystalline basement or sites in hard and brittle sedimentary sequences that are more prone to injection-induced seismicity and permanent damage.
1 January 2014 in International Journal of Greenhouse Gas Control