Soil mineral (or inorganic) nitrogen (SMN), which primarily exists as exchangeable and soluble ammonium (NH4+) and the nitrate (NO3−) ions, represents readily available nitrogen for plant growth. Over the years a 2M potassium chloride (KCl) solution has become the extraction solution of choice for extracting SMN. In the research and service laboratories, either distillation-titration method (DTM) or colorimetric method (CM) is virtually the standard to measure NH4+- and NO3−-N in the 2M KCl soil extracts. However, being a time-consuming and labor intensive method, DTM generally has a very low throughput. Likewise, CM is affected by interferences from pH variation, color, turbidity, presence of organic species, and some other constituents in the extracts. In contrast, diffusion conductivity method (DCM) is a less expensive and high throughput one, which is also relatively free from common interferences. In this study, we, therefore, compared the extraction efficiency of various KCl concentrations and performance of diffusion conductivity method (DCM) with DTM in measuring NH4+-N and NO3−-N in KCl extracts of 32 agricultural soils of Georgia. A 0.2M KCl solution extracted statistically similar amounts of NH4+-N and NO3−-N as did 2M KCl, suggesting that a 10-fold dilute KCl solution than the standard 2M KCl might be good enough to extract and estimate the most of SMN. For the analyses of NH4+- and NO3−-N in the KCl extracts, the DCM produced results statistically similar to those produced by DTM. The deviation between the results given by DCM and DTM was no more than ±10%. Thus, DCM appears to be an attractive alternative to the labor intensive and time-consuming DTM for measuring NH4+- and NO3−-N in the KCl extract of soils in the research and service laboratories.
15 March 2018 in Journal of the Science of Food and Agriculture
The distillation–titration method (DTM) is a standard procedure used by most laboratories to measure ammonium-nitrogen (NH4-N) in the total Kjeldahl N (TKN) digests of various kinds of agricultural and environmental samples. These samples may have TKN contents ranging from less than 100 ppb to as high as percentage levels. However, the DTM procedure generally leads to a very low throughput because it is labor intensive and time-consuming. At the current practical quantitation limit (PQL) of 300 ppb established at the Feed and Environmental (FEW) Laboratory, University of Georgia, the DTM procedure is less applicable to low TKN surface water samples. In this study, we therefore compared the performance of diffusion conductivity method (DCM) and colorimetric method (CM) with DTM in measuring NH4-N in the TKN digests of 29 different samples representing surface waters, lagoons, manures, poultry litters, and environmental wastes. Acceptable accuracy and precision were achieved for various QC samples by all three methods. For widely different sample matrices and TKN contents, the NH4-N in the TKN digests measured by DCM and CM both agreed well with that measured by DTM. However, the linear working range of CM is limited within 0.2 to 5.0 ppm, whereas DCM is linear at a wider range of 0.01 to 2000 ppm. With DCM, the PQL of TKN is at 13 ppb, much less than the 300 ppb in DTM and 520 ppb in CM. Both DCM and CM require increasing the pH of the working TKN digest to a highly alkaline range. To meet such pH requirement, the minimum dilution need for DCM is twofold, where as that CM is fourfold. Because of greater mandatory dilution requirement coupled with a greater PQL, CM may often fail to measure NH4-N in the working TKN digest of some low TKN surface water samples. On the other hand, with some environmental waste samples containing TKN at percentage level, CM would require multistep dilution of the digests prior to measurement, thus allowing dilution-related error as well as requiring additional labor. In contrast, DCM can measure both low TKN surface waters and high TKN environmental wastes without any major limitations. Moreover, DCM may work well without any adjustment of sample background in the calibration standards. Thus DCM appears to be an attractive alternative to the labor-intensive and time-consuming DTM for measuring NH4-N in the TKN digests of various kinds of agricultural and environmental samples in the analytical services laboratories.
12 October 2017 in Journal of the Science of Food and Agriculture
Loblolly ( Pinus taeda) and slash ( Pinus elliottii) pine tree biomass are significant renewable energy resources for bioenergy industries in the Southeastern United States. There is a great need for evaluation of their properties (relevant to production and evaluation-screening for bioenergy extraction) by rapid but accurate analytical methods like near infrared reflectance (NIR) spectroscopy. However, no attempts have been made so far to develop useful NIR spectroscopic calibration models for analyzing biomass of these two species. In this study, acceptable NIR spectroscopic calibration models were developed for: gross calorific value, GCV ( n = 181; R2 = 0.83; ratio of standard error of cross-validation to deviation, RSCD = 2.32; ratio of standard error of cross-validation to inter-quartile distance, RSCIQ = 2.68); net calorific value, NCV ( n = 184; R2 = 0.83; RSCD = 2.31; RSCIQ = 2.69); ash-free calorific value, AFCV ( n = 184; R2 = 0.83; RSCD = 2.24; RSCIQ = 2.49); moisture ( n = 181; R2 = 0.85; RSCD = 2.54; RSCIQ = 2.30); ash ( n = 180; R2 = 0.86; RSCD = 2.65; RSCIQ = 2.62); total carbon, C ( n = 101; R2 = 0.95; RSCD = 3.01; RSCIQ = 5.66); total nitrogen, N ( n = 87; R2 = 0.95; RSCD = 4.24; RSCIQ = 4.76); and total sulfur, S ( n = 83; R2 = 0.97; RSCD = 4.17; RSCIQ = 3.05) contents of these biomasses though the calibration models for NCV and AFCV are indirect calibration. Prediction of the independent validation sets yielded good agreement between the NIR spectroscopic predicted values and the laboratory reference values for each of: GCV ( n = 92; r2 = 0.89; ratio of performance to deviation; RPD = 3.01; ratio of performance to inter-quartile distance, RPIQ = 3.16); NCV ( n = 91; r2 = 0.83; RPD = 2.43; RPIQ = 3.06); AFCV ( n = 91; r2 = 0.80; RPD = 2.25; RPIQ = 2.83); moisture ( n = 92; r2 = 0.82; RPD = 2.38; RPIQ = 2.40); ash ( n = 89; r2 = 0.81; RPD = 2.30; RPIQ = 2.66); C ( n = 43; r2 = 0.90; RPD = 3.14; RPIQ = 3.23); N ( n = 44; r2 = 0.95; RPD = 4.33; RPIQ = 5.96); and S ( n = 42; r2 = 0.93; RPD = 3.67; RPIQ = 3.24) contents, indicating that all eight calibration models had good quantitative information. The standard errors of prediction for all models were less than twice the corresponding standard error of laboratory. Therefore, precise, accurate, and rapid analysis of calorific values and C, N, S contents of these biomasses can be done using these novel NIR spectroscopic calibration models developed.
1 October 2010 in Journal of Colloid and Interface Science