KARLA NOGUEIRA MATOS

Mrs. KARLA NOGUEIRA MATOS

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2026 in Journal of the World Federation of Orthodontists
Verified
Journal Article
Open access
KMKARLA NOGUEIRA MATOS
KARLA NOGUEIRA MATOS
HGHugo Henrique dos Santos Dantas Guimarães
Hugo Henrique dos Santos Dantas Guimarães
External root resorption (ERR) and external cervical resorption (ECR) are common orthodontic complications with prognostic impact. Early, accurate detection helps prevent irreversible damage. Our objective is to synthesize diagnostic accuracy of artificial intelligence (AI) for ERR/ECR on orthodontic imaging and compare performance by imaging modality and model architecture. Data Sources: Web of Science, PubMed, Scopus, Embase, IEEE Xplore, and Cochrane Library (through September 9, 2025). Original human or ex-vivo imaging studies of AI models for ERR/ECR with extractable accuracy data. Two reviewers independently extracted TP/FP/TN/FN. Pooled sensitivity/specificity and HSROC were estimated via a bivariate random-effects model; risk of bias with QUADAS-2; PROSPERO: CRD420251103690. Five studies (1089 images) met criteria. Pooled sensitivity was 90.7% (95% CI, 85.6-94.1) and specificity 91.8% (95% CI, 86.0-95.3). CBCT-based models outperformed panoramic models, and transformer/hybrid architectures showed slightly higher accuracy than CNNs, though subgroup power was limited. Heterogeneity was moderate (I² ≈ 55-61%), plausibly related to variable diagnostic thresholds, mixed tooth types, and differing reference standards (orthodontists/endodontists/radiologists). Small evidence base (n = 5), small geographically limited datasets, and absence of true external validation restrict generalizability. With <10 studies, formal publication-bias testing was not feasible. AI shows high accuracy for ERR/ECR, particularly with CBCT and transformer/hybrid models, yet moderate heterogeneity and limited generalizability warrant cautious interpretation. AI should augment, not replace, clinician judgment within explainable, standardized workflows. Priorities include open multicenter annotated datasets, harmonized thresholds/protocols, and external validation to enable reliable clinical adoption.

4 May 2026 in Journal of Dentistry
Verified
Journal Article
Open access
HGHugo Henrique dos Santos Dantas Guimarães
Hugo Henrique dos Santos Dantas Guimarães
KMKARLA NOGUEIRA MATOS
KARLA NOGUEIRA MATOS
To systematically evaluate evidence on artificial intelligence (AI) for root canal filling (RCF) detection and radiographic assessment of obturation quality. Eligible studies assessed AI-based models for RCF detection and/or obturation quality assessment using dental radiographs and cone-beam computed tomography (CBCT). PubMed, Embase, Scopus, ClinicalTrials.gov, Cochrane Library, Web of Science, Google Scholar, and Open Science Framework were searched up to March 2026. Studies evaluating AI-based models for RCF detection and/or obturation quality assessment were included. Data were synthesized qualitatively. Risk of bias was assessed with QUADAS-2 and certainty of evidence with GRADE. Thirteen studies were included, comprising 12,513 examinations from periapical, panoramic, bitewing, and CBCT images. For RCF detection, sensitivity ranged from 0.85 to 1.00 and specificity from 0.92 to 1.00. For obturation quality assessment, sensitivity ranged from 0.79 to 1.00 and specificity from 0.99 to 1.00, with better performance in periapical radiographs and CBCT than panoramic radiographs. Risk of bias was mainly related to patient selection and lack of external validation, and substantial heterogeneity was observed. AI-based models show promise for RCF detection, whereas performance for obturation quality assessment is more variable and modality-dependent. AI may serve as an adjunct in endodontic radiographic evaluation. AI-based systems may affect clinical workflows through automated radiographic pre-screening, image interpretation support, and real-time second-opinion validation. These tools may reduce interpretation time, improve diagnostic consistency, and support detection of endodontic findings, particularly in high-volume settings. External validation and prospective studies are required before routine clinical implementation.

23 June 2026 in European Journal of Oral Sciences
Verified
Journal Article
Open access
HGHugo Henrique dos Santos Dantas Guimarães
Hugo Henrique dos Santos Dantas Guimarães
KMKARLA NOGUEIRA MATOS
KARLA NOGUEIRA MATOS
Accessory root canal anatomy, including second mesiobuccal (MB2) and middle mesial canals (MMC), is difficult to identify and may compromise endodontic outcomes when missed, supporting artificial intelligence (AI)‐based diagnostic tools. This systematic review (CRD420261415943) included studies evaluating AI models for accessory canal or root canal orifice identification, emphasizing MB2, MMC, and canal orifice detection. Study characteristics, imaging modalities, AI architectures, reference standards, outcomes, and validation strategies were extracted. Risk of bias was assessed using QUADAS‐2 and certainty of evidence using GRADE. Seven studies were included. Most evaluated MB2 detection or segmentation on cone‐beam computed tomography (CBCT); one assessed root canal orifice detection using dental operating microscope images, and one evaluated MMC detection. AI approaches included U‐Net, YOLO, CNN‐based pipelines, Inception V3‐based machine learning, ChatGPT‐4o, and nnU‐Net. For MB2 detection/classification, sensitivity or recall ranged from 80.0% to 100%, specificity from 99.4% to 100% when reported, accuracy from 84.9% to 97.8%, and area under the curve from 0.57 to approximately 0.90. Segmentation/localization outcomes were heterogeneous. AI shows promise as an adjunct for accessory canal detection, particularly MB2 on CBCT, but evidence remains limited.

13 July 2026 in International Orthodontics
Verified
Journal Article
Open access
KMKARLA NOGUEIRA MATOS
KARLA NOGUEIRA MATOS
TSTainá Belline da Silva
Tainá Belline da Silva
LALeonardo Matos de Faria Almeida
Leonardo Matos de Faria Almeida
MAMarcos de Faria Almeida
Marcos de Faria Almeida
HGHugo Henrique dos Santos Dantas Guimarães
Hugo Henrique dos Santos Dantas Guimarães
To systematically identify, appraise, and synthesize the evidence on clinical, biomechanical, and digital factors associated with refinement-related outcomes after the first series of clear aligners. This systematic review was conducted according to PRISMA 2020 and followed the Synthesis Without Meta-analysis (SWiM) guidance. Electronic searches were performed in PubMed/MEDLINE, Embase, Scopus, Web of Science, Cochrane Library, and Google Scholar. Clinical studies involving patients treated with clear aligners were included when they reported refinement, additional aligners, finishing aligners, midcourse correction, refinement plans, planned-versus-achieved discrepancies, or treatment-continuation outcomes after the first aligner series. Risk of bias was assessed using design-specific tools according to study design. Owing to heterogeneity in definitions, outcomes, units of analysis, and measurement methods, a structured narrative synthesis was performed. Twenty studies were included. Refinement-related outcomes were heterogeneously defined, including refinement aligners, additional aligners, finishing phases, refinement plans, midcourse correction, and first-refinement scans. The evidence suggested that refinement burden may be associated with malocclusion complexity, extraction treatment, interproximal reduction strategies, severe spacing, larger correction sequences, and movement-specific limitations. Rotations, intrusion, vertical correction, transverse expansion, and selected anterior movements showed reduced predictability. Remote monitoring appeared to reduce appointment burden but did not consistently reduce refinement need. Evidence for adjunctive technologies and machine-learning prediction remained preliminary. Refinement after the first aligner series should be interpreted as a multifactorial clinical outcome rather than a uniform finishing procedure. Standardized definitions and prospective studies are needed to clarify patient-, tooth-, movement-, and treatment-plan-level predictors. CRD420261416896.