Robert Armiger

Mr. Robert Armiger

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2011 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YOYoshito Otake
Yoshito Otake
MAMehran Armand
Mehran Armand
RARobert Armiger
Robert Armiger
MKMichael D. Kutzer
Michael D. Kutzer
EBEhsan Basafa
Ehsan Basafa
RTRussell H. Taylor
Russell H. Taylor
Intraoperative patient registration may significantly affect the outcome of image-guided surgery (IGS). Image-based registration approaches have several advantages over the currently dominant point-based direct contact methods and are used in some industry solutions in image-guided radiation therapy with fixed X-ray gantries. However, technical challenges including geometric calibration and computational cost have precluded their use with mobile C-arms for IGS. We propose a 2D/3D registration framework for intraoperative patient registration using a conventional mobile X-ray imager combining fiducial-based C-arm tracking and graphics processing unit (GPU)-acceleration. The two-stage framework 1) acquires X-ray images and estimates relative pose between the images using a custom-made in-image fiducial, and 2) estimates the patient pose using intensity-based 2D/3D registration. Experimental validations using a publicly available gold standard dataset, a plastic bone phantom and cadaveric specimens have been conducted. The mean target registration error (mTRE) was 0.34±0.04 mm (success rate: 100%, registration time: 14.2 s) for the phantom with two images 90° apart, and 0.99±0.41 mm (81%, 16.3 s) for the cadaveric specimen with images 58.5° apart. The experimental results showed the feasibility of the proposed registration framework as a practical alternative for IGS routines.

27 July 2023 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
LOLuke E. Osborn
Luke E. Osborn
RVRama Venkatasubramanian
Rama Venkatasubramanian
MHMeiyong Himmtann
Meiyong Himmtann
CMCourtney W. Moran
Courtney W. Moran
JPJonathan M. Pierce
Jonathan M. Pierce
RARobert Armiger
Robert Armiger

19 September 2014 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
RMRyan J. Murphy
Ryan J. Murphy
RARobert Armiger
Robert Armiger
JLJyri Lepistö
Jyri Lepistö
SMSimon C. Mears
Simon C. Mears
RTRussell H. Taylor
Russell H. Taylor
MAMehran Armand
Mehran Armand

8 March 2021 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
LOLuke E Osborn
Luke E Osborn
CMCourtney W Moran
Courtney W Moran
MJMatthew S Johannes
Matthew S Johannes
ESErin E Sutton
Erin E Sutton
JWJared M Wormley
Jared M Wormley
RARobert Armiger
Robert Armiger
Objective. Full restoration of arm function using a prosthesis remains a grand challenge; however, advances in robotic hardware, surgical interventions, and machine learning are bringing seamless human-machine interfacing closer to reality. Approach. Through extensive data logging over 1 year, we monitored at-home use of the dexterous Modular Prosthetic Limb controlled through pattern recognition of electromyography (EMG) by an individual with a transhumeral amputation, targeted muscle reinnervation, and osseointegration (OI). Main results. Throughout the study, continuous prosthesis usage increased (1% per week, p < 0.001) and functional metrics improved up to 26% on control assessments and 76% on perceived workload evaluations. We observed increases in torque loading on the OI implant (up to 12.5% every month, p < 0.001) and prosthesis control performance (0.5% every month, p < 0.005), indicating enhanced user integration, acceptance, and proficiency. More importantly, the EMG signal magnitude necessary for prosthesis control decreased, up to 34.7% ( p < 0.001), over time without degrading performance, demonstrating improved control efficiency with a machine learning-based myoelectric pattern recognition algorithm. The participant controlled the prosthesis up to one month without updating the pattern recognition algorithm. The participant customized prosthesis movements to perform specific tasks, such as individual finger control for piano playing and hand gestures for communication, which likely contributed to continued usage. Significance. This work demonstrates, in a single participant, the functional benefit of unconstrained use of a highly anthropomorphic prosthetic limb over an extended period. While hurdles remain for widespread use, including device reliability, results replication, and technical maturity beyond a prototype, this study offers insight as an example of the impact of advanced prosthesis technology for rehabilitation outside the laboratory.

1 January 2013 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
NNNoushin Niknafs
Noushin Niknafs
RMRyan J. Murphy
Ryan J. Murphy
RARobert Armiger
Robert Armiger
JLJyri Lepistö
Jyri Lepistö
MAMehran Armand
Mehran Armand
This study addresses the effects of cartilage thickness distribution and compressive properties in the context of optimal alignment planning for periacetabular osteotomy (PAO). The Biomechanical Guidance System (BGS) is a computer-assisted surgical suite assisting surgeon’s in determining the most beneficial new alignment of a patient’s acetabulum. The BGS uses biomechanical analysis of the hip to find this optimal alignment. Articular cartilage is an essential component of this analysis and its physical properties can affect contact pressure outcomes. Patient-specific hip joint models created from CT scans of a cohort of 29 dysplastic subjects were tested with four different cartilage thickness profiles (one uniform and three nonuniform) and two sets of compressive characteristics. For each combination of thickness distribution and compressive properties, the optimal alignment of the acetabulum was found; the resultant geometric and biomechanical characterization of the hip were compared among the optimal alignments. There was an average decrease of 49.2 +/- 22.27% in peak contact pressure from the preoperative to the optimal alignment over all patients. We observed an average increase of 19 +/- 7.7 degrees in center-edge angle and an average decrease of 19.5 +/- 8.4 degrees in acetabular index angle from the preoperative case to the optimized plan. The optimal alignment increased the lateral coverage of the femoral head and decreased the obliqueness of the acetabular roof in all patients. These anatomical observations were independent of the choice for either cartilage thickness profile, or compressive properties. While patient-specific acetabular morphology is essential for surgeons in planning PAO, the predicted optimal alignment of the acetabulum was not significantly sensitive to the choice of cartilage thickness distribution over the acetabulum. However, in all groups the biomechanically predicted optimal alignment resulted in decreased contact pressure

30 March 2016 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
RMRyan J. Murphy
Ryan J. Murphy
RARobert Armiger
Robert Armiger
JLJyri Lepistö
Jyri Lepistö
MAMehran Armand
Mehran Armand
Populations suffering from developmental dysplasia of the hip typically have reduced femoral coverage and experience joint pain while walking. Periacetabular osteotomy (PAO) is one surgical solution that realigns the acetabular fragment. This challenging surgery has a steep learning curve. Existing navigation systems for computer-assisted PAO neither track the released fragment nor offer the means to assess fragment location. An intraoperative workstation—the biomechanical guidance system (BGS)—developed for PAO incorporates intraoperative fragment tracking and acetabular characterization through radiographic angles and joint biomechanics. In this paper, we investigate the accuracy and effectiveness of the BGS for bone fragment tracking and acetabular characterization in clinical settings as compared to conventional techniques and postoperative assessments. We also report the issues encountered and our remedies when using the BGS in the clinical setting. Eleven consecutive patients (aged 22–48, mean 34, years) underwent 12 PAO surgeries (one bilateral surgery) where the BGS collected information on acetabular positioning. These measurements were compared with postoperative CT data and manual measurements made intraoperatively. No complications were reported during surgery, with surgical time—95–210 (mean 175) minutes—comparable to reported data for the conventional approach. The BGS-measured acetabular positioning showed strong agreement with postoperative CT measurements (−0.3–9.2, mean 3.7, degrees), whereas larger differences occurred between the surgeon’s intraoperative manual measurements and postoperative CT measurements (−2.8–21.3, mean 10.5, degrees). The BGS successfully tracked the acetabular fragment in a clinical environment without introducing complications to the surgical workflow. Accurate 3D positioning of the acetabulum may provide more information intraoperatively (e.g., anatomical angles and biomechanics) without adversely impacting the surgery to better understand potential patient outcomes.