An ordinary portland cement and two portland limestone cements [15 and 35% weight-to-weight ratio (w/w) limestone content] were used for concrete and reinforced mortar specimens preparation. The specimens were exposed to two corrosive solutions (chloride sulfate and chloride) at 5°C. Total (acid-soluble) and free (water-soluble) chloride contents, and apparent chloride diffusion coefficients, were determined in concrete specimens. Reinforcement corrosion half-potential and current density, mass loss of steel rebars, and carbonation depth were measured in mortar specimens. Limestone cements showed very good behavior, although the environments were very corrosive. Total and free chloride ions concentration increased with exposure time and limestone content. Limestone cements showed less capability of binding chlorides than pure portland cement. The cement with low limestone content was the most effective in preventing reinforcement corrosion during mortar exposure to the combined chloride-sulfate solution, although it allowed the most intensive corrosion in the case of the chloride-bearing solution. The presence of sulfates led to higher chloride ion concentrations, less chloride binding and, generally, higher values of chloride diffusion coefficient, and also promoted reinforcement corrosion to a greater extent. Low temperature conditions retained a relatively low corrosion rate.
This study explores the potential of calcium-rich fly ash from the Ptolemais region in Greece as a partial cement replacement for improving sulfate resistance in cementitious composites. An integrated experimental program, combining mechanical testing, electrochemical corrosion monitoring and microstructural characterization, was designed to capture the progression of material properties over time and their impact on performance. The experimental results proved that, at early ages, incorporation of fly ash led to reductions in compressive, tensile and bond strengths, attributed to delayed pozzolanic reactivity. However, over prolonged curing, secondary reactions consumed portlandite and generated additional calcium silicate hydrate, refining the pore network and reducing permeability. These microstructural improvements were associated with enhanced mechanical performance, improved durability indices and markedly lower reinforcement corrosion rates. Bond tests further revealed a shift from brittle to a more ductile response, offering advantages for repair applications. These findings establish calcium-rich Ptolemais fly ash as a as a sustainable and promising supplementary cementitious material that substantially enhances the long-term durability and sulfate resistance of cementitious systems.
16 December 2013 in International Journal of Corrosion
This study refers to the cooling tower of Megalopolis (construction 1975) and protection from corrosive environment. The maintenance of the cooling tower took place in 2008. The cooling tower was badly damaged from corrosion of reinforcement. The parabolic cooling towers (factory of electrical power) are a typical example of construction, which has a special aggressive environment. The protection of cooling towers is usually achieved through organic coatings. Because of the different environmental impacts on the internal and external side of the cooling tower, a different system of paint application is required. The present study refers to the damages caused by corrosion process. The corrosive environments, the application of this painting, the quality control process, the measures and statistics analysis, and the results were discussed in this study. In the process of quality control the following measurements were taken into consideration: (1) examination of the adhesion with the cross-cut test, (2) examination of the film thickness, and (3) controlling of the pull-off resistance for concrete substrates and paintings. Finally, this study refers to the correlations of measurements, analysis of failures in relation to the quality of repair, and rehabilitation of the cooling tower. Also this study made a first attempt to apply the specific corrosion inhibitors in such a large structure.
This study examines the potential use of Electrolytic Manganese Dioxide (EMD) residue as a replacement of cement (20%wt by cement weight) in construction materials to provide anticorrosion protection on reinforcing steel and improve the strength of cementitious materials under sulfate attack. To assess the corrosion parameters, the constructed building materials were immersed in a 5%wt sulfate salt (Na2SO4), while concrete samples incorporating 20%wt EMD were prepared and subjected to mechanical, porosity and thermal tests. Moreover, SEM images were obtained in order to examine the microstructure of concrete and the extent of damage caused by sulfate ions. The results demonstrate that the inclusion of EMD caused a notable rise in the corrosion of steel bars within cement mortars, as well as a decrease in the mechanical strength of the building materials. Overall, the experimental outcomes of the study suggest that the incorporation of high volume (20%wt) EMD residue leads to the degradation of all measured properties.