Mehmet Uyuklu

Dr. Mehmet Uyuklu


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2009 in Scandinavian Journal of Clinical and Laboratory Investigation
Verified
Journal Article
Closed access
PDF file
OBOguz K. Baskurt
Oguz K. Baskurt
MHMax R. Hardeman
Max R. Hardeman
MUMehmet Uyuklu
Mehmet Uyuklu
PUPinar Ulker
Pinar Ulker
MCMelike Cengiz
Melike Cengiz
HMHerbert J. Meiselman
Herbert J. Meiselman
Measurement of red blood cell (RBC) deformability by ektacytometry yields a set of elongation indexes (EI) measured at various shear stresses (SS) presented as SS-EI curves, or tabulated data. These are useful for detailed analysis, but may not be appropriate when a simple comparison of a global parameter between groups is required. Based on the characteristic shape of SS-EI curves, two approaches have been proposed to calculate the maximal RBC elongation index (EImax) and the shear stress required for one-half of this maximal deformation (SS1/2): (i) linear Lineweaver-Burke (LB) model; (ii) Streekstra-Bronkhorst (SB) model. Both approaches have specific assumptions and thus may be subject to the measurement conditions. Using RBC treated with various concentrations of glutaraldehyde (GA) and data obtained by ektacytometry, the two approaches have been compared for nine different ranges of SS between 0.6–75 Pa. Our results indicate that: (i) the sensitivity of both models can be affected by the SS range and limits employed; (ii) over the entire range of SS-data, a non-linear curve fitting approach to the LB model gave more consistent results than a linear approach; (iii) the LB method is better for detecting SS1/2 differences between RBC treated with 0.001–0.005% glutaraldehyde (GA) and for a 40% mixture of rigid cells but is equally sensitive to SB for 10% rigid cells; and (iv) the LB and SB methods for EImax are equivalent for 0.001% and 0.003% GA and 40% rigid, with the SB better for 0.005% GA and the LB better for 10% rigid.

1 January 2009 in Biorheology
Verified
Journal Article
Closed access
PDF file
OBOguz K. Baskurt
Oguz K. Baskurt
MHM.R. Hardeman
M.R. Hardeman
MUMehmet Uyuklu
Mehmet Uyuklu
PUPinar Ulker
Pinar Ulker
MCMelike Cengiz
Melike Cengiz
HMHerbert J. Meiselman
Herbert J. Meiselman
In December 2008, the International Society for Clinical Hemorheology organized a workshop to evaluate and compare three ektacytometer instruments for measuring deformability of red blood cells (RBC): LORCA (Laser-assisted Optical Rotational Cell Ana

1 January 2009 in Clinical Hemorheology and Microcirculation
Verified
Journal Article
Closed access
PDF file
MUMehmet Uyuklu
Mehmet Uyuklu
MCMelike Cengiz
Melike Cengiz
PUPinar Ulker
Pinar Ulker
THTimea Hever
Timea Hever
JTJulien Tripette
Julien Tripette
OBOguz K. Baskurt
Oguz K. Baskurt
Blood samples used in hemorheological studies may be stored for a period of time, the effects of storage have yet to be fully explored. This study evaluated the effects of storage temperature (i.e., 4°C or 25°C) and duration on RBC deformability and

1 January 2009 in Clinical Hemorheology and Microcirculation
Verified
Journal Article
Closed access
PDF file
OBOguz K. Baskurt
Oguz K. Baskurt
MUMehmet Uyuklu
Mehmet Uyuklu
PUPinar Ulker
Pinar Ulker
MCMelike Cengiz
Melike Cengiz
NNNorbert Nemeth
Norbert Nemeth
HMHerbert J. Meiselman
Herbert J. Meiselman
The International Society for Clinical Hemorheology organized a workshop to compare three instruments for measuring RBC aggregation: LORCA, Myrenne Aggregometer and RheoScan-A. The Myrenne Aggregometer provides indices at stasis (M) and at low shear

20 November 2009 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
OBOguz K. Baskurt
Oguz K. Baskurt
MUMehmet Uyuklu
Mehmet Uyuklu
HMHerbert J. Meiselman
Herbert J. Meiselman
Red blood cells (RBC) in normal human blood undergo reversible aggregation at low flow or stasis. The extent and kinetics of this phenomenon have been studied using various optical and electrical methods, yet results using such methods are not always in concordance. This study employed a horizontal glass tube in which blood flow could be established, then abruptly stopped. Normal blood and RBC suspensions with enhanced or decreased aggregation were studied. Light transmittance (LT) and electrical impedance at 100 kHz were recorded during high-shear flow and for 120 s after flow was abruptly stopped during which RBC aggregation occurs. Capacitance values were also obtained based on the imaginary part of impedance data and recorded. Various aggregation parameters were calculated, using the time course of LT, impedance, and capacitance, then compared with each other and with results from laboratory aggregometers. RBC aggregation parameters were calculated, using the time course of impedance data often failed to correlate with known changes of aggregation, even reporting aggregation for cells in nonaggregating media (i.e., RBC in buffered saline). Alternatively, RBC aggregation parameters based upon the time course of capacitance data are in general agreement with those derived from LT data and with RBC aggregation indexes, measured using commercial instruments.

1 January 2011 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MUMehmet Uyuklu
Mehmet Uyuklu
MCMurat Canpolat
Murat Canpolat
HMHerbert J. Meiselman
Herbert J. Meiselman
OBOguz K. Baskurt
Oguz K. Baskurt
The reversible aggregation of red blood cells (RBC) is of current basic science and clinical interest. Using a flow channel and light transmittance (LT) through RBC suspensions, we have examined the effects of wavelength (500 to 900 nm) on the static and dynamic aspects of RBC aggregation for normal blood and suspensions with reduced or enhanced aggregation; the effects of oxygenation were also explored. Salient observations include: 1. significant effects of wavelength on aggregation parameters reflecting the extent of aggregation (i.e., number of RBC per aggregate); 2. no significant effects of wavelength on parameters reflecting the time course of RBC aggregation; 3. a prominent influence of hemoglobin oxygen saturation on both extent and time-course related aggregation parameters measured at wavelengths less than 700 nm, but only on the time-course at 800 nm; and 4. the power of parameters in detecting a given alteration of RBC aggregation is affected by wavelength, in general being greater at higher wavelengths. It is recommended that light sources with wavelengths around 800 nm be used in instruments for measuring RBC aggregation via LT.