ahmet kürşat Kara

Dr. ahmet kürşat Kara

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2022 in Journal of Surgery and Medicine
Verified
Journal Article
Open access
PDF file
ZKZahir Kizilay
Zahir Kizilay
MYMurat Ozcan Yay
Murat Ozcan Yay
AKahmet kürşat Kara
ahmet kürşat Kara
VAVarol Aydın
Varol Aydın
'+st+' Ishimoto Y, Yoshimura N, Muraki S, Yamada H, Nagata K, Hashizume H, et al. Association of lumbar spondylolisthesis with low back pain and symptomatic lumbar spinal stenosis in a population-based cohort: the Wayakama spine study. Spine (Phila Pa 1976). 2017;42(11):E666–71. doi: 10.1097/BRS.0000000000001960. DOI: https://doi.org/10.1097/BRS.0000000000001960 Liu J, Deng H, Long X, Chen X, Xu R, Liu Z. A comparative study of perioperative complications between transforaminal versus posterior lumbar interbody fusion in degenerative lumbar spondylolisthesis. Eur Spine J. 2016;25(5):1575–80. doi: 10.1007/s00586-015-4086-8. DOI: https://doi.org/10.1007/s00586-015-4086-8 Kayanama M, Hashimoto T, Shigenobu K, Oha F, Ishida T, Yamane S. Non-fusion surgery for degenerative spondylolisthesis using artificial ligament stabilization: surgery indication and clinical results. Spine. 2005;30:588–92. doi: 10.1097/01.brs.0000154766.74637.5e. DOI: https://doi.org/10.1097/01.brs.0000154766.74637.5e Fan G, Wu X, Yu S, Sun Q, Guan X, Zhang H, et al. Clinical outcomes of posterior lumbar interbody fusion versus minimally invasive transforaminal lumbar interbody fusion in three-level degenerative lumbar stenosis. Biomed Res Int. 2016;2016:9540298. doi: 10.1155/2016/9540298. DOI: https://doi.org/10.1155/2016/9540298 Chrastil J, Patel AA. Complications associated with posterior and transforaminal lumbar interbody fusion. J Am Acad Orthop Surg. 2012;20(5):283–91. doi: 10.5435/JAAOS-20-05-283. DOI: https://doi.org/10.5435/JAAOS-20-05-283 Zhao FD, Yang W, Shan Z, Wang J, Chen HX, Hong ZH, et al. Cage migration after transforaminal lumbar interbody fusion and factors related to it. Orthop Surg. 2012;4(4):227–32. doi: 10.1111/os.12004. DOI: https://doi.org/10.1111/os.12004 Wong AP, Smith ZA, Nixon AT, Lawton CD, Dahdaleh NS, Wong RH, et al. Intraoperative and perioperative complications in minimally invasive transforaminal lumbar interbody fusion: a review of 513 patients. J Neurosurgy Spine. 2015;22(5):487–95. doi: 10.3171/2014.10.SPINE14129. DOI: https://doi.org/10.3171/2014.10.SPINE14129 Aoki Y, Yamagata M, Nakajima F, Ikeda Y, Takahashi K. Posterior migration of fusion cages in degenerative lumbar disease treated with transforaminal lumbar interbody fusion: a report of three cases. Spine (Phila Pa 1976). 2009;34(1):E54–8. doi: 10.1097/BRS.0b013e3181918aae. DOI: https://doi.org/10.1097/BRS.0b013e3181918aae Hey HW, Hee HT. Open and minimally invasive transforaminal interbody fusion: comparison of intermediate results and complications. Asian Spine J. 2015;9(2):185–93. doi: 10.4184/asj.2015.9.2.185. DOI: https://doi.org/10.4184/asj.2015.9.2.185 Aoki Y, Yamagata M, Nakajima F, Ikeda Y, Shimizu K, Yoshihara M, et al. Examining risk factors of posterior migration of fusion cages following transforaminal lumbar interbody fusion: a possible limitation unilateral pedicle screw fixation. J Neurosurg Spine. 2013;13:381–7. doi: 10.3171/2010.3.SPINE09590. DOI: https://doi.org/10.3171/2010.3.SPINE09590 Smith AJ, Arginteanu M, Moore F, Steinberger A, Camins M. Increased incidence of cage migration and nonunion in instrumented transforaminal lumbar interbody fusion with bioabsorbable cages. J Neurosurg Spine. 2010;13:388–93. doi: 10.3171/2010.3.SPINE09587. DOI: https://doi.org/10.3171/2010.3.SPINE09587 Grant JP, Oxland TR, Dvorak MF. Mapping the structural properties of the lumbosacral vertebral endplates. Spine. 2001;26:271–3. doi: 10.1097/00007632-200104150-00012. DOI: https://doi.org/10.1097/00007632-200104150-00012 Labrom RD, Tan JS, Reilly CW, Tredwell SJ, Fisher CG, Oxland TR. The effect of interbody cage positioning on lumbosacral vertebral endplate failure in compression. Spine (Phila Pa 1976). 2005;30(19):E556–61. doi: 10.1097/01.brs.0000181053.38677.c2. DOI: https://doi.org/10.1097/01.brs.0000181053.38677.c2 Copyright (c) 2022 Zahir Kızılay, Murat Özcan Yay, Ahmet Kürşat Kara, Varol Aydın This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

12 May 2026 in World Neurosurgery: X
Verified
Journal Article
Open access
ATAbdullah Topçu
Abdullah Topçu
AKahmet kürşat Kara
ahmet kürşat Kara
ZKZahir Kizilay
Zahir Kizilay
NÇNesibe Kahraman Çetin
Nesibe Kahraman Çetin

1 October 2026 in Frontiers in Surgery
Verified
Journal Article
Open access
PDF file
AKahmet kürşat Kara
ahmet kürşat Kara
OIOzan Işık
Ozan Işık
Background: Patients recovering from lumbar fusion increasingly seek guidance from large language model (LLM) chatbots when their surgeon is unavailable, but the accuracy, completeness, and safety-related content of such responses have not been compared across models for the postoperative period. Objective: To compare the accuracy, quality, safety-related content, and readability of responses from ChatGPT, Gemini, and Claude to frequently asked postoperative lumbar fusion questions, and to identify the question types for which responses are weakest. Methods: Thirty questions, compiled by three neurosurgeons and grouped into six clinical categories, were submitted to each model, each with a standardized, patient-oriented prompt requesting warning signs. Ninety anonymized, randomized responses were rated independently by three blinded neurosurgeons for accuracy and four quality subdomains (clarity, completeness, relevance, and patient safety) on 4-point scales. Readability (Flesch–Kincaid, Flesch Reading Ease, and Gunning Fog), word count, and responses meeting an operational screening criterion for potential harm were also assessed. Models were compared with Friedman and Holm-corrected pairwise tests. Results: Accuracy was high for all models without significant differences. Quality, clarity, completeness, relevance, and patient safety differed globally, but effect sizes were small (Kendall's W : 0.10–0.21) and, after correction across the six outcome families, only quality and completeness remained significant, with Gemini scoring lower than ChatGPT and Claude. Gemini had the most favorable readability. ChatGPT responses were the shortest (mean 294 vs. 462 and 445 words); length was unrelated to completeness or readability. Two Gemini responses (6.7%) and none from ChatGPT or Claude met a post hoc operational screening criterion for potential harm (a score of ≤2 on accuracy or patient safety from at least one of three raters, without concurrence from the other two); no response was adjudicated as actually harmful. In exploratory question- and category-level analyses, responses tended to be rated highest for standardized questions and lowest for those requiring individualized judgment or interpretation of wound-related symptoms. Conclusion: Responses from contemporary LLMs to common postoperative lumbar fusion questions were generally rated as accurate, with small between-model differences and a model-level divergence between readability and completeness. Because safety-related content was explicitly prompted and no patient outcomes were assessed, these findings describe the quality of safety-related information rather than clinical safety. LLMs may support postoperative patient education but should not replace physician guidance, particularly for warning signs and patient-specific recovery decisions.

18 February 2026 in World Neurosurgery: X
Verified
Journal Article
Open access
AKahmet kürşat Kara
ahmet kürşat Kara
SYSoner Yaycioğlu
Soner Yaycioğlu
ZKZahir Kizilay
Zahir Kizilay
ETErkut Turan
Erkut Turan
NÇNesibe Kahraman Çetin
Nesibe Kahraman Çetin

20 June 2026 in Brain Sciences
Verified
Journal Article
Open access
PDF file
DBDuygu Baykal
Duygu Baykal
MEMustafa Umut Etli
Mustafa Umut Etli
MAMUHAMMED ENES ATİK
MUHAMMED ENES ATİK
ZGZekeriya Gedikli
Zekeriya Gedikli
MÇMEHMET ZİYA ÇETİNER
MEHMET ZİYA ÇETİNER
SISemra Işık
Semra Işık
Objectives: This study aimed to evaluate the utility of MRI-based morphometric and qualitative parameters in identifying patients with suspected normal pressure hydrocephalus (NPH) associated with shunt surgery selection following clinical and lumbar puncture evaluation. Methods: We retrospectively analyzed 134 participants: 84 symptomatic patients evaluated for suspected NPH and 50 age-matched controls with normal brain MRI findings. Symptomatic patients were categorized according to subsequent clinical management following lumbar puncture evaluation into those who underwent shunt surgery (Shunt group) and those who received conservative management (Conservative group). The Evans index, fronto-occipital horn ratio (FOHR), bicaudate index, callosal angle, ventricular measurements, and disproportionately enlarged subarachnoid space hydrocephalus (DESH) components were analyzed. The discriminatory performance of MRI parameters for shunt surgery selection was assessed using ROC analysis; independent predictors of shunt surgery selection were determined using logistic regression. Results: Although conventional ventricular indices and ventricular dimensions were significantly greater in symptomatic patients than in the control group (p < 0.001), baseline continuous MRI measurements did not significantly differ between the Shunt and Conservative groups (p > 0.05). Callosal angle demonstrated no discriminatory value for shunt surgery selection. In univariate analyses, an Evans Index > 0.36, a bicaudate index > 0.23, and a DESH score > 2 were associated with shunt surgery selection. High-convexity tightness and an Evans Index > 0.36 differed significantly between groups and remained independently associated with shunt surgery selection in multivariable analysis. Conclusions: Ventricular width-based indices alone appear insufficient for identifying patients selected for shunt surgery among individuals evaluated for suspected NPH. Both qualitative and quantitative MRI features, particularly high-convexity tightness and an Evans Index > 0.36, were independently associated with shunt surgery selection following routine clinical assessment. Integrating multimodal imaging parameters with clinical evaluation may provide a more reliable approach for identifying patients who are ultimately selected for shunt surgery following lumbar puncture assessment.

29 July 2026 in Frontiers in Surgery
Verified
Journal Article
Open access
PDF file
AKahmet kürşat Kara
ahmet kürşat Kara
ZKZahir Kızılay
Zahir Kızılay
Background: S1 pedicle screw loosening remains a clinically significant complication in lumbosacral fusion, with reported incidences ranging from 15.6% to 41.9%. In patients undergoing multi-level posterior lumbar fusion with concomitant symptomatic but stable L5–S1 pathology, it remains unclear whether extending the construct to the sacrum is necessary. Methods: This retrospective study included 60 patients who underwent multi-level posterior lumbar instrumentation (fusion constructs spanning 2–4 segments) between November 2023 and April 2024. All patients had symptomatic L5–S1 pathology (disc herniation or stenosis) without radiographic instability, and required fusion for upper lumbar pathology. Patients with L5–S1 instability (>3 mm translation or >10° angulation on flexion–extension radiographs) were excluded. Group 1 ( n = 30) underwent selective L5–S1 decompression without S1 fixation; Group 2 ( n = 30) underwent TLIF with S1 pedicle screw instrumentation. Clinical outcomes (ODI and VAS), perioperative parameters, and complications were evaluated at 1, 6, and 24 months. Results: Groups were comparable at baseline. Operative time (148.4 ± 26.1 vs. 204.7 ± 32.8 min, p < 0.001), estimated blood loss (376.7 ± 114.3 vs. 653.3 ± 211.8 mL, p < 0.001), and hospital stay (3.7 ± 0.9 vs. 4.4 ± 0.8 days, p = 0.004) were significantly lower in Group 1. Both groups demonstrated significant within-group improvements in ODI and VAS scores at all time points ( p < 0.001). No statistically significant between-group differences were observed in ODI or VAS at 6 months or 24 months. Group 1 showed significantly lower VAS at 1 month ( p = 0.022). Radiographic S1 screw loosening was observed in 7 of 30 patients (23.3%) in Group 2. Conclusion: In this retrospective cohort, selective decompression of the L5–S1 segment without S1 instrumentation was associated with comparable mid-term clinical outcomes while reducing operative time, blood loss, and S1 screw-related complications.