Ressy Jaya Yanti

Ms. Ressy Jaya Yanti

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2024 in Building Services Engineering Research & Technology
Verified
Journal Article
Closed access
FFFaridah Faridah
Faridah Faridah
SUSentagi Sesotya Utami
Sentagi Sesotya Utami
DWDinta Dwi Agung Wijaya
Dinta Dwi Agung Wijaya
RYRessy Jaya Yanti
Ressy Jaya Yanti
WPWahyu Sukestyastama Putra
Wahyu Sukestyastama Putra
BABillie Adrian
Billie Adrian
Indoor air quality is the foundation of a good indoor environment. The COVID-19 pandemic further highlighted the importance of providing real-time airflow distribution information within the Building Environmental Monitoring System (BEMS) to minimize the risk of infectious airborne transmission. This paper discusses the process of developing a predictive model for indoor airflow distribution prediction with indoor and outdoor input parameters using machine learning and its implementation in healthy BEMS for a classroom in the tropical climate region of Yogyakarta, Indonesia. This paper encompassed field measurement and simulation involving outdoor climate conditions and the operational status of the classroom’s windows, Air Conditioning units, and fans. Three machine learning models were constructed using OLS, LASSO, and Ridge methods. Datasets for the modeling were generated from CFD model simulations in IES VE and were assessed for correlation. The mean temperature and velocity differences between the CFD model simulation and measurement results are 0.21°C and 0.083 m/s, respectively. Outdoor climate conditions and the operational status of the classroom’s utilities significantly influence the indoor airflow distribution characteristics. The three models indicate a relatively poor performance, where the classroom had a relatively low sensitivity to input changes. However, the best model performance was achieved using the LASSO method, with average values from post-normalization of [ ] and Root Mean Square Error (RMSE) of 0.336 and 0.077, respectively. The model was implemented in healthy BEMS on the “Platform for Healthy and Energy Efficient Building Management System.” Practical Application: This research proposed a machine learning model of indoor airflow characteristics of a classroom in Yogyakarta. The proposed model can be adapted to produce monitoring systems that best represent the related conditions. The method can be adopted to develop a relatively simple, low-cost sensor or model to monitor an indoor environment. Future studies may explore the results of the real-world implementation in a case study.

2 February 2022 in JOURNAL OF ARCHITECTURE AND URBANISM
Verified
Journal Article
Open access
PDF file
CMChristina Mediastika
Christina Mediastika
ASAnugrah S. Sudarsono
Anugrah S. Sudarsono
SUSentagi S. Utami
Sentagi S. Utami
IFIsnen Fitri
Isnen Fitri
RDRizka Drastiani
Rizka Drastiani
ZRZulfi Rachman
Zulfi Rachman
Irresponsible noise management by the concerned authorities and society’s indifference has made noise in Indonesian urban areas a nightmare. The current noise regulation in Indonesia, which define 55 dB(A) as the lowest permissible noise level generated in residential areas, is outdated. This study investigates how urban communities reacted to the implementation of this outdated regulation. Data was collected by searching online open sources for noise-related keywords used in public complaints, court cases, authority campaigns, etc. The collected data was then plotted in an Excel sheet to create a modest statistical trend, and the detailed information on how the government and court ruled the case was treated as a transcript to be analysed qualitatively. The study results are to be compared and discussed with noise facts of those in more advanced countries. The discussion shows that the noise case in Indonesia is significantly minor compared to other countries with similar populations. Noisemakers were reported to have won in 44% of noise complaints that went to court. This may be the reason for the Indonesians’ apathy toward the settlement of noise-related complaints by the city government and the fairness of tribunal processes.

1 April 2023 in ARTEKS : Jurnal Teknik Arsitektur
Verified
Journal Article
Open access
PDF file
CMChristina Mediastika
Christina Mediastika
ASAnugrah Sabdono Sudarsono
Anugrah Sabdono Sudarsono
SUSentagi Sesotya Utami
Sentagi Sesotya Utami
IFIsnen Fitri
Isnen Fitri
RDRizka Drastiani
Rizka Drastiani
ZRZulfi Rachman
Zulfi Rachman
Like other developing countries where traffic is a significant sound nuisance, traffic in Indonesian urban areas is boisterous. How this condition is regulated by the Indonesian government so that the community can live healthily and comfortably is a very crucial issue. Unfortunately, Indonesia has not had any sound environmental improvement since the regulation was enacted. Additionally, regulators and government officers who run the rule carelessly worsen the condition. This study aims to study how sound is regulated in Indonesia’s central and local governments, what types of sound or noise and levels are covered, and whether recent local regulations have been enacted to regulate sound in Indonesian cities. The study mainly uses quantitative, i.e., snowball or chain referral sampling techniques, to collect sound regulations applied in ten large and busy cities in Indonesia. Then, the qualitative stage was conducted based on the content of the rules. The data shows that the Indonesian government at both the central and regional levels does not have legal standing to regulate noise caused by the absence of noise regulation at the statutory level that can force those who violate the law to be punished. The only regulation is by the Minister of Environment, dated 1996, which is referenced nationally and adopted by most cities without or with minor modifications. This study found that (1) six of the ten cities regulate only one type of noise among various types of noise, (2) twelve of the 35 local regulations incorporate noise regulations into air pollution regulations instead of stand-alone regulations, (3) because provinces and cities adopt central regulations, the lowest noise level follows the central standard at 55 dB for settlement area without specific frequency ranges, (4) there is no straightforward procedure on how measurements to be carried out except in regulations stipulated by Yogyakarta province. There is also a fact that a standardized procedure for measuring noise is vital to be included in the regulation because unskilled government officials collected invalid data in dealing with a noise complaint leading to an unresolved situation.

1 February 2025 in Ecological Engineering & Environmental Technology
Verified
Journal Article
Open access
TPThomas Oka Pratama
Thomas Oka Pratama
AWAgus Budhie Wijatna
Agus Budhie Wijatna
SSSunarno Sunarno
Sunarno Sunarno
HSHermin Kartika Sari
Hermin Kartika Sari
RYRessy Jaya Yanti
Ressy Jaya Yanti
MWMemory Motivanisman Waruwu
Memory Motivanisman Waruwu
Abnormal increases in radon gas (222Rn) concentrations in soil, groundwater, and atmosphere have been consistently observed as precursors of seismic activity, especially near active faults. In this study, we focus on earthquake prediction using IoT-based radon monitoring near the active fault in...

15 October 2026 in Sensors
Verified
Journal Article
Open access
PDF file
RYRessy Jaya Yanti
Ressy Jaya Yanti
Eiji KondoEiji Kondo
Eiji Kondo
TITomohiko Igasaki
Tomohiko Igasaki
Electrohysterography (EHG) is an advanced, noninvasive technique for characterizing myometrial activity from the maternal abdominal surface. Despite its clinical relevance, the adoption of EHG in wearable systems is hindered by variability in electrode configurations and a lack of integrated system design. A PRISMA 2020-based systematic review of publications from September 1997 to January 2026 was conducted using IEEE Xplore, PubMed, Semantic Scholar, ScienceDirect, SpringerLink, MDPI, IOP, and Frontiers, supplemented by Crossref searches via Publish or Perish and manual citation tracking. Of the 1084 records identified, 91 publications were included in the evidence synthesis. The analysis examined electrode configurations, wearable design, and measurement methodologies, focusing on the effects of electrode density and placement on signal quality and clinical usability. The reviewed literature indicates that configurations employing approximately 8–16 electrodes represent a practical range for balancing spatial characterization and clinical usability. However, the findings reveal persistent challenges related to the limited integration of electrode design, signal acquisition, and analytical methods. This evidence underscores the need for an integrated approach that considers flexible electrode interfaces, standardized electrode configurations, and adaptive signal processing techniques. By aligning technological improvements with clinical requirements, this study identifies practical considerations for developing wearable maternal–fetal monitoring systems.