Dong Hee Choi

Dr. Dong Hee Choi


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Aerosol and Air Quality Research
Verified
Journal Article
Closed access
DCDong Hee Choi
Dong Hee Choi
DKDong Hwa Kang
Dong Hwa Kang

1 January 2017 in Aerosol and Air Quality Research
Verified
Journal Article
Closed access
DCDong Hee Choi
Dong Hee Choi
SCSeock Hwan Choi
Seock Hwan Choi
DKDong Hwa Kang
Dong Hwa Kang

1 October 2013 in Building and Environment
Verified
Journal Article
Closed access
DKDong Hwa Kang
Dong Hwa Kang
DCDong Hee Choi
Dong Hee Choi
YSYoon-Bok Seong
Yoon-Bok Seong
MYMyoung Souk Yeo
Myoung Souk Yeo
KKKwang Woo Kim
Kwang Woo Kim

12 July 2010 in Indoor and Built Environment
Verified
Journal Article
Closed access
PDF file
DCDong Hee Choi
Dong Hee Choi
DKDong Hwa Kang
Dong Hwa Kang
SKSun Sook Kim
Sun Sook Kim
MYMyoung Souk Yeo
Myoung Souk Yeo
KKKwang Woo Kim
Kwang Woo Kim
The effects of using a non-adhesive floating method for the installation of wallpaper and plywood flooring on emissions and indoor concentrations of volatile organic compounds (VOCs) in full-scale test rooms were investigated. The emissions of VOCs from the wallpaper, plywood flooring, adhesives and composite materials were measured in a small-scale chamber. Toluene was the major VOC detected from the adhesives for both the wallpaper and plywood flooring. The thin and porous characteristics of wallpaper allowed a rapid emission of toluene from the adhesive applied on the wall composite materials; whereas, the thick and complex composition of the plywood flooring appeared to slow down the emission of toluene. The thickness and diffusion characteristics of the finishing materials can affect the appearance and emissions from the adhesive applied.

6 November 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
DCDong Hee Choi
Dong Hee Choi
DKDong Hwa Kang
Dong Hwa Kang
This study investigates indoor/outdoor relationships of airborne particles under controlled pressure difference across the building envelope in Korean multifamily apartments. On-site field experiments on 14 apartment housing units located in urban areas in Korea are conducted to measure the indoor/outdoor ratios of number concentrations of size-resolved particles (0.3–0.5, 0.5–1.0, 1.0–3.0, 3.0–5.0, 5.0–10.0, >10.0 μm). To set identical pressure difference conditions across the envelope of each housing unit for better comparison of I/O ratio results, and to examine the effect of pressure difference on the I/O relations, indoor–outdoor pressure difference was controlled at 10, 30, and 50 Pa using a blower door depressurization procedure. Simultaneously, the air leakage characteristics of housing units are measured using the typical blower door pressurization-depressurization test method to correlate air leakage data and I/O ratios. As expected, moderately airtight housing units (ACH50 ≤ 4.4) show lower I/O ratios than average leaky housing units (ACH50 > 4.4); still, the averaged I/O ratios of finer sized particles (0.3–0.5, 0.5–1.0, and 1.0–3.0 μm) in the moderately airtight housing units were 0.75, 0.59, and 0.61 at an I-O pressure difference of 50 Pa, and 0.62, 0.51, and 0.49 at 10 Pa. The study indicates that indoor residents in moderately airtight Korean multifamily housing units with relatively small envelope area can still be exposed to high concentrations of outdoor originated fine particles.

19 May 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
BPBo Ram Park
Bo Ram Park
YEYe Seul Eom
Ye Seul Eom
DCDong Hee Choi
Dong Hee Choi
DKDong Hwa Kang
Dong Hwa Kang
The purpose of this study was to evaluate outdoor PM2.5 infiltration into multifamily homes according to the building characteristics using regression models. Field test results from 23 multifamily homes were analyzed to investigate the infiltration factor and building characteristics including floor area, volume, outer surface area, building age, and airtightness. Correlation and regression analysis were then conducted to identify the building factor that is most strongly associated with the infiltration of outdoor PM2.5. The field tests revealed that the average PM2.5 infiltration factor was 0.71 (±0.19). The correlation analysis of the building characteristics and PM2.5 infiltration factor revealed that building airtightness metrics (ACH50, ELA/FA, and NL) had a statistically significant (p < 0.05) positive correlation (r = 0.70, 0.69, and 0.68, respectively) with the infiltration factor. Following the correlation analysis, a regression model for predicting PM2.5 infiltration based on the ACH50 airtightness index was proposed. The study confirmed that the outdoor-origin PM2.5 concentration in sufficiently leaky units could be up to 1.59 times higher than that in airtight units.