Jennifer Gernhardt

Ms. Jennifer Gernhardt


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2026 in Animals
Verified
Journal Article
Open access
PDF file
JGJennifer Gernhardt
Jennifer Gernhardt
TRThomas Reuter
Thomas Reuter
GFGuido Fritsch
Guido Fritsch
NSNicole Schulze
Nicole Schulze
KMKathrin Mählmann
Kathrin Mählmann
CLChristoph Lischer
Christoph Lischer
The accessory carpal bone (ACB) is an important component of the equine carpus and a clinically relevant site of fracture, yet its detailed morphology and motion characteristics remain incompletely characterized. The objectives of this ex vivo study were to characterize the three-dimensional morphometry of the native ACB using computed tomography (CT), to assess its kinematics during carpal flexion and extension using dynamic 3D CT, and to evaluate fragment behavior following a standardized vertical fracture. Twelve equine forelimbs underwent CT imaging in the neutral carpal position, maximal flexion, and maximal extension before and after standardized osteotomy simulating a vertical plane fracture. Morphometric measurements included dorsopalmar width, lateromedial thickness, proximodistal length, and radii of medial concavity and lateral convexity. The ACB exhibited consistent geometry among specimens of comparable size. Dynamic imaging revealed independent physiological motion relative to the other carpal bones of the ACB, characterized by medial movement of its medial concave surface toward the caudal aspect of the radius during flexion. Following fracture creation, widening of the fracture gap and proximal displacement of the palmar fragment occurred predominantly in flexion, whereas the neutral carpal position and maximal extension promoted fracture gap closure and distal displacement. These findings improve understanding of ACB morphology and biomechanics and may have implications for fracture pathogenesis and surgical fixation strategies.

21 December 2025 in Veterinary Surgery
Verified
Journal Article
Open access
JGJennifer Gernhardt
Jennifer Gernhardt
TRThomas Reuter
Thomas Reuter
KMKathrin Mählmann
Kathrin Mählmann
NSNicole Schulze
Nicole Schulze
CLChristoph J. Lischer
Christoph J. Lischer
Objective: To compare the feasibility and biomechanical stability of two surgical techniques for fixation of vertical plane fractures of the accessory carpal bone (ACB). Study design: Randomized experimental ex vivo study. Sample population: Eight equine accessory carpal bones were included in a control group. A total of 20 equine cadaveric forelimbs were randomly assigned into two groups ( n = 10 per group). Methods: Vertical plane fractures were created palmar to the extensor sulcus using an oscillating saw. In Group 1 (CS), fractures were stabilized with two 4.5 mm cortical screws in lag fashion. In Group 2 (XP), fixation included one 4.5 mm cortical screw in lag fashion and a laterally applied angular stable X‐plate with four 2.7 mm locking screws. Control ACBs were excised and tested under axial compression using a four‐column testing machine. Postoperative specimens in Groups CS and XP were tested under the same conditions. The failure mode was assessed radiographically. Results: The mean maximum strength of native bone was 11.26 (±2.14) kN. Two constructs per group were excluded due to cortical screw protrusion. No difference in failure load was observed (CS: 6.82 [±2.34] kN; XP: 8.02 [±1.10] kN; p = .7558). Failure mode analysis revealed a greater fracture gap size ( p = .0039) and implant bending in CS specimens ( p = 1.074e‐7). Conclusion: Both techniques were feasible, though neither restored native bone strength. Clinical significance: A lateral X‐plate with a single cortical screw demonstrated equivalent biomechanical performance to two cortical screws and was technically less demanding, offering a simpler fixation option for ACB fractures.

30 October 2025 in Veterinary Surgery
Verified
Journal Article
Open access
JGJennifer Gernhardt
Jennifer Gernhardt
PBPeter Böttcher
Peter Böttcher
JEJ. Corinna Eule
J. Corinna Eule
KMKathrin Mählmann
Kathrin Mählmann
EMEva Müller
Eva Müller
CLChristoph J. Lischer
Christoph J. Lischer
Objective: To describe surgical repair of an orbital wall fracture communicating with the caudal maxillary sinus using a three dimensional (3D)‐printed, patient‐specific implant (PSI). Study design: Case report. Animal: A 25‐year‐old Haflinger mare (370 kg). Methods: The mare presented with severe chemosis and emphysema of the left upper and lower eyelid of 2‐weeks duration due to a fracture of the ventral floor and inner wall of the left orbit that communicated with the caudal maxillary sinus. Computed tomographic (CT) data were used to design a PSI replicating the inner surface of the unfractured orbit. The data were converted to an STL file and 3D‐printed using polylactic acid (PLA) filament. Surgical access was obtained via a concho‐frontal sinus flap combined with sinoscopy. To reconstruct and seal the orbit, the PSI was lined with porcine small intestinal submucosa and secured to the inner orbital wall using two 3.0 mm titanium locking screws and synthetic, non‐absorbable transosseous fiber loops. Results: The emphysema resolved postoperatively, and ocular function was unrestricted by the implant. Infection developed subcutaneously adjacent to the transosseous suture fixation at the maxillary bone but resolved with conservative management. Follow‐up CT at 11 weeks and owner reports after 18 months confirmed a favorable cosmetic and functional outcome, with only minimal residual ptosis of the left upper eyelid. Conclusion: Application of a PSI axially to the left orbit successfully reconstructed the orbital wall and resolved the communication with the caudal maxillary sinus. Clinical significance: Patient‐specific implants represent a novel surgical option for the repair of complex orbital wall fractures in horses.