Alberto Tenconi

Prof. Alberto Tenconi

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
ABAldo Boglietti
Aldo Boglietti
RBRadu Bojoi
Radu Bojoi
ACAndrea Cavagnino
Andrea Cavagnino
ATAlberto Tenconi
Alberto Tenconi
A performance analysis of three-phase and dual three-phase (DTP) induction pulsewidth modulation (PWM) inverter-fed motor drives is conducted in this paper. The focus is on the efficiency performance of high-frequency DTP machines compared to their three-phase counterparts in low/medium power applications. For this purpose, a DTP machine, having two sets of stator three-phase windings spatially shifted by 30 electrical degrees (asymmetrical six-phase winding configuration), was tested for both six-phase and three-phase winding configurations under the same magnetic conditions. Simulation and experimental results are presented to evaluate the efficiency performance of three-phase and dual-three induction motor drives employing PWM voltage source inverters.

3 March 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
FGFrancesco Giordano
Francesco Giordano
Alessandro CiociaAlessandro Ciocia
Alessandro Ciocia
Paolo Di LeoPaolo Di Leo
Paolo Di Leo
Andrea MazzaAndrea Mazza
Andrea Mazza
Filippo SpertinoFilippo Spertino
Filippo Spertino
Silvio VaschettoSilvio Vaschetto
Silvio Vaschetto
This paper proposes a procedure for the control of Electric Vehicle (EV) batteries, aiming to have an optimal matching between local renewable production, domestic loads and EV consumption. The procedure starts with the analysis of historical PhotoVoltaic (PV), EV and domestic load profiles. Load and PV profiles are forecasted using statistical based algorithms, while the expected patterns of EV usages are forecasted using a combination of statistics and clustering techniques. Then, the forecasted profiles are used to estimate future energy balances trough an optimization process. Finally, the real time management corrects the forecasting logic and checks the parameters of the EV storage to guarantee its correct and safe operation. Three different EV usage profile (obtained by the clustering of 215 real users) are shown and their impact on the energy balance of EV-PV-home systems is quantified. The results are finally compared with those obtained with a traditional rule-based logic working without forecasts, by also reporting a detailed analysis of the main aspects having an impact on the results.

1 June 2008 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
GKG. Kovacevic
G. Kovacevic
ATAlberto Tenconi
Alberto Tenconi
RBRadu Bojoi
Radu Bojoi

1 January 2002
Verified
Conference Paper
Closed access
MCM.C. Caponet
M.C. Caponet
FPF. Profumo
F. Profumo
ATAlberto Tenconi
Alberto Tenconi
EMI filters for equipment, in which power electronic converters are used, often are designed by trial and error. Moreover, the design is carried out taking into account the total noise produced by the equipment. Thanks to the separation of the noise into the differential mode and the common mode components, it is possible to understand which of the two components is dominant and therefore the filters design can be done straightforwardly by directly measuring the necessary common mode and differential mode attenuation. In this way, it is possible to avoid an expensive and useless heavy filter and satisfy the standards limits only by filtering the dominant component using a smaller, cheaper and optimized filter. In this paper, the authors show a five steps design procedure for the design of EMI filters for power electronics equipment. Experimental results for a studied case are given to show the validity of this approach.

1 November 2006
Verified
Conference Paper
Closed access
VOValentin Oleschuk
Valentin Oleschuk
RBRadu Bojoi
Radu Bojoi
FPFrancesco Profumo
Francesco Profumo
ATAlberto Tenconi
Alberto Tenconi
ASAlexandar M. Stankovic
Alexandar M. Stankovic
Novel methodology of synchronized pulsewidth modulation (PWM) has been disseminated for control of six-phase (dual-three phase) induction machine drives fed by two three-phase inverters with both single and separate DC voltage sources. Control algorithms are based in this case on the 30deg-phase-shifting of control and output signals of two standard voltage source inverters. Four basic schemes of synchronized PWM, applied for control of six-phase drives, have been analyzed and compared. Simulations results are given for continuous, discontinuous and combined versions of synchronized PWM. The spectra of the phase voltage of the six-phase drives with algorithms of synchronized PWM do not contain even harmonics and sub-harmonics, which is especially important for the high power/current applications

10 February 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Sandro RubinoSandro Rubino
Sandro Rubino
RBRadu Bojoi
Radu Bojoi
EAEric Armando
Eric Armando
ATAlberto Tenconi
Alberto Tenconi
The predictive control algorithms for electrical drives are currently subject to considerable interest and development. In particular, the predictive torque control is a competitive solution that may replace in the future the conventional control schemes based on linear controllers. Therefore, the paper proposes a predictive torque control for surface permanent magnet motor drives requiring a wide constant power range. The predictive algorithm uses a deadbeat direct flux vector control approach for the simultaneous control of the stator flux amplitude and torque-producing current component. The proposed control scheme is suitable for applications requiring a wide speed range with current and voltage constraints. The proposed deadbeat torque controller has been tested on a fractional slot permanent magnet machine and the experimental results demonstrate the drive full controllability, including deep flux-weakening operation with limitation of the load angle.