Cleistanthus collinus leaf extracts are consumed for suicidal purposes in southern India. The boiled decoction is known to be more toxic than the fresh leaf juice. Although several compounds have been isolated and their toxicity tested, controversy remains as to which compounds are responsible for the high level of toxicity of C. collinus. We report herein that cleistanthoside A is the major toxin in the boiled aqueous extract of fresh leaves and causes death in rats in small doses. The toxicity of the boiled extract prepared in the manner described can be attributed entirely to cleistanthoside A. Cleistanthin A could also be isolated from the boiled extract, albeit in trace amounts. As hypotension not responding to vasoconstrictors is the cause of death in patients who have consumed the boiled extract, effects of cleistanthoside A on the determinants of blood pressure, namely, force of cardiac contraction and vascular resistance, were tested in isolated organ experiments. Cleistanthoside A has a direct vasoconstrictor effect; however, it inhibits ventricular contractility. Therefore, the notion that the shock in C. collinus poisoning is of vascular origin must be considered carefully, and the possibility of cardiogenic shock must be studied. We present the crystal structure of cleistanthin A and show the potency of fast NMR methods (NOAH4-BSCN-NUS) in the full spectral assignment of cleistanthoside A as a real-world sample of a natural product. We also compare the results of the NOAH4-BSCN-NUS NMR experiments with conventional NMR methods.
Rationale: Intra-arterial blood pressure measurement is the cornerstone of hemodynamic monitoring in Intensive Care Units (ICU). Accuracy of the measurement is dependent on the dynamic response of the measuring system, defined by its natural frequency ( fnatural ) and damping coefficient ( Zdamping ) which are estimated with a Fast-flush test. Locating the experimentally measured fnatural and Zdamping on the plot in the original paper by Gardner (1981) which defined the acceptable limits for these 2 parameters, has long been the only way to determine the accuracy of the pressure measurement. In this paper, we extend the current understanding of the effect of poor dynamic response of the measurement system, enhance the usefulness of Gardner’s plots by providing a numerical value for the error in pressure measurement (for a given set of conditions) and depict the gradation of error value as heat maps, and also demonstrate the usefulness of a tunable filter for error correction. Objectives: (i) Estimation of the amplitude of error in pressure measurement through simulations based on real-world data, and development of heat-maps for easy use by physicians to assess if the recording conditions are optimal (ii) A new method to correct the error. Methods and Results: Simulated blood pressure waveforms of various heart rates and pressure levels were passed through simulated measurement systems with varying fnatural and Zdamping . The numerical errors in systolic and diastolic pressures and mean error in the measured pressure were used to generate heat maps denoting the errors for the various recording conditions, in the same plot as that by Gardner (1981). Performance of a tunable filter to correct the error is demonstrated. Conclusions: In many clinical settings the measurement of intra-arterial pressure is prone to significant error. The proposed tunable filter is shown to improve the accuracy of intra-arterial pressure recording.
Electrocardiogram (ECG) today largely remains paper-based making them inaccessible for research and innovation. To address this unmet need, we describe an end-to-end framework for ECG signal extraction from images using a four-stage pipeline and lay down the associated data generation requirements. The signal extraction stages include perspective correction, reorientation of paper, lead isolation and signal segmentation that converts signals to voltage units enabling precise digital reconstruction of the original waveforms. Our data generation methodology generates 72,080 simulated ECG images from open source digital signal datasets. We apply novel, realistic augmentations such as coffee stains, imaging shadows and introduce 3D deformation using Blender3D. Furthermore, we employ text-to-image and image-to-image workflows by synthesizing backgrounds around ECG images using the SDXL model with IP Adapter. Our pipeline achieves acceptable signal extraction with a Pearson correlation coefficient of 0.78 and processing speeds of ≈ 1.03 seconds, which is four times faster than existing methods on a related benchmark dataset. This advancement enables practical use of ECG digitization in fast-paced clinical environments, reducing cardiology consultation turnaround times and facilitating digital storage for population health analysis.
Atrial fibrillation (AFib) represents a critical diagnostic challenge in clinical cardiology, calling for automated detection systems capable of robust performance across diverse clinical environments. We present a computationally efficient deep neural network architecture for AFib detection that demonstrates exceptional generalizability despite training on a modest dataset. Our convolutional neural network, comprising 17 million parameters, was trained on 67,432 12-lead electrocardiograms and subsequently validated on over 1.1 million ECG recordings spanning six independent public datasets. On CPU, the model processes a 10-second ECG in 200 ms, enabling real-time inference capabilities. Our model achieves state-of-the-art performance, with an average area under the receiver operating characteristic curve (AUROC) of 0.97, an average sensitivity of 0.83, and an average specificity of 0.96 across six external validation cohorts. These metrics rank among the highest reported in the literature, while preserving computational efficiency suitable for resource-constrained environments. A key innovation of our approach is the implementation of channel-masking methodology, enabling seamless operation across variable lead configurations without model retraining. This flexibility allows deployment from single-lead ambulatory monitors to comprehensive 12-lead clinical systems using identical network weights. Gradient-based saliency analysis confirms the model’s attention to physiologically relevant features, particularly P-wave morphology and lead II characteristics, thereby enhancing clinical interpretability and trustworthiness. Our findings also establish that a single, well-curated small training dataset can yield a compact yet highly generalizable AFib detection system suitable for deployment across diverse clinical settings, from critical care monitoring to ambulatory screening applications. The combination of robust cross-dataset performance, computational efficiency, and clinical interpretability positions this approach as a viable solution for largescale AFib diagnosis and monitoring programs.
Atrial fibrillation (AFib) is the most prevalent sustained cardiac arrhythmia, yet most deep learning detectors are validated on a single cohort and few report uncertainty. We developed a compact 14M-parameter convolutional neural network for binary AFib classification from 10 s, 12-lead ECG at 500 Hz, trained exclusively on the HDXML dataset (67,432 ECGs; 9628 AFib) with on-the-fly augmentation for noise, drift and missing channels. Using one unchanged checkpoint, we evaluated six independently sourced public cohorts totaling over 1.25 million recordings, including MIMIC-IV critical care and two ambulatory Holter cohorts. All metrics are reported with 95% confidence intervals from a cluster bootstrap at the patient, recording or subject levels. ROC–AUC exceeded 0.95 in every cohort, from 0.960 (95% CI 0.956–0.963) on CODE-15 to 0.999 (0.998–0.999) on SPH, including 0.966 (0.965–0.967) on MIMIC-IV with 75.3% sensitivity and 97.7% specificity, 0.963 (0.929–0.987) on CPSC 2021 and 0.995 (0.988–0.999) on MIT-BIH. Performance was stable under progressive lead masking without retraining, and median inference took 110 ms per segment on a server-class CPU without a GPU. A compact network trained on one curated source can therefore generalize across hospitals, countries and recording hardware. This study is retrospective; prospective validation is required before clinical use.