New materials and technologies have become the main drivers for reducing energy demand in the building sector in recent years. Energy efficiency can be reached by utilization of materials with thermal storage potential; among them, phase change materials (PCMs) seem to be promising. If they are used in combination with solar collectors in heating applications or with water chillers or in chilled ceilings in cooling applications, PCMs can provide ecological benefits through energy savings during the building’s operational phase. However, their environmental value should be analyzed by taking into account their whole lifecycle. The purpose of this paper is the assessment of PCMs at the material level as well as at higher levels, namely the component and building levels. Life cycle assessment analyses are based on information from PCM manufacturers and building energy simulations. With the newly developed software “Storage LCA Tool” (Version 1.0, University of Stuttgart, IABP, Stuttgart, Germany), PCM storage systems can be compared with traditional systems that do not entail energy storage. Their benefits can be evaluated in order to support decision-making on energy concepts for buildings. The collection of several case studies shows that PCM energy concepts are not always advantageous. However, with conclusive concepts, suitable storage dimensioning and ecologically favorable PCMs, systems can be realized that have a lower environmental impact over the entire life cycle compared to traditional systems.
Closed adsorption storages have been investigated in several projects for heat storage in building applications with focus on energy density and performance. This study complements this research with the assessment of the environmental impacts over the life cycle. Global warming potential (GWP) was chosen as the assessment criterion. Selected sorption materials in combination with water as the refrigerant were analyzed first by themselves and then embedded in a generic storage configuration. Sensible storage in water served as the reference benchmark. Results on material and component level showed that the relative storage capacity compared to water under realistic operating conditions reached values of below 4 and 2.5, respectively, in the best cases. Since the effort for producing the sorbents as well as the auxiliary material demand for assembling storage components was significantly higher than in the reference case, the specific environmental impact per storage capacity also turned out to be ~2.5 to ~100 times higher. We therefore suggest focusing sorption storage research on applications that (a) maximize the utilization of the uptake of sorbents, (b) do not compete with water storages, and (c) require minimal auxiliary parts.
On the basis of the Number of Transfer Units (NTU) method a functional relation between electric power for fans/pumps and effectiveness in dry coolers and wet cooling towers is developed. Based on this relation, a graphical presentation method of monitoring and simulation data of heat rejection units is introduced. The functional relation allows evaluating the thermodynamic performance of differently sized heat rejection units and comparing performance among them. The method is used to evaluate monitoring data of dry coolers of different solar cooling field projects. The novelty of this approach is that performance rating is not limited by a design point or standardized operating conditions of the heat exchanger, but is realizable under flexible conditions.
Fouling is a permanent problem in process technology and is estimated to cost 0.25% of the gross national product. Evaporative cooling systems are especially susceptible to air-side fouling: as they work with untreated outside air, they are exposed to both natural (e.g., pollen) and human-made (e.g., industrial dust) contaminants. In addition, suspended solid particles and dissolved salts in the spray water are an issue. In this study we analyzed an approach for fouling detection based on a semi-physical (grey-box) cooling tower model which we calibrated with measurement data. A test series with reliable laboratory data indicates good applicability of the model. In three datasets, the performance decreases due to fouling (scaling, which was provoked intentionally) in the range of 5–11% were clearly detected. When applied to measurement data of two cooling towers in real applications, the model also proved to be well calibratable with relatively little data (two to four operating days). For two data sets, the model yielded reasonable results when applied to long term data: a cooling tower cleaning could be retraced and nominal operation was verified during the remaining time. During the analysis of a third data set a temporary performance deviation was found, which could not be explained with the recorded data. Thus, the approach turned out to be generally applicable but requires further verification and refinement in order to increase the robustness. If successful, it can be transferred to a commercial product for need-oriented maintenance in order to reduce cooling tower operating costs and environmental impact.
9 April 2024 in International Sustainable Energy Conference - Proceedings
In order to mitigate climate change, a wide range of negative emission technologies, such as pyrolytic carbon capture and storage, must be used in the future. This study therefore examines a specific application example for the energy supply with a pyrolysis plant that is operated with locally available biomass in the smallest district of the city of Freiburg. It is shown that such a supply concept is feasible and that the economic efficiency of the supply concept depends on the system output as well as the amount of local biomass and the revenues from the sale of the biochar. Of the six pyrolysis plants examined, two proved to be a promising alternative to the current wood chip boiler. By switching to an energy supply with a pyrolysis plant, the district could save several hundred tons of CO2 per year. The resulting total negative emissions would amount to almost 1200 tons of CO2 per year.