Bacterial contamination of platelet components (PC) is the most prevalent risk for transfusion-transmitted infection. Based on the recent studies with optimal culture methods of expired PC, the prevalence of bacterial contamination is estimated to occur in approximately one in 750 to one in 1000 PC. Only within the last few years have the magnitude of the risks and the range of clinical outcomes associated with bacterial contamination been extensively characterized. Despite increased recognition of bacterial contamination of PC, transfusion-related sepsis is infrequently reported. This has largely been attributed to passive reporting systems, and low levels of clinical awareness for transfusion-related sepsis by primary care physicians. The risk for transfusion of contaminated PC has generally been characterized per component. Importantly, because patients require repeated transfusions of PC during a period of transfusion-dependent thrombocytopenia, it is appropriate to express the risk to receive a contaminated PC on a patient exposure basis. Assuming that the average hematology oncology patient may receive seven PC during a 28-day period of support, the risk of exposure to a contaminated PC is in the range of one in 150 per patient. This level of risk would not be acceptable for other intravenous medications. With increased appreciation of the risk of bacterial contamination, methods were developed to limit the risk of transfusion-transmitted bacteremia. This article focuses on those interventions that have been implemented in routine practice. The most important methods employed to mitigate the risk are improved skin disinfection, initial blood draw diversion, bacterial detection and pathogen inactivation/reduction. These technologies are now undergoing increased use in the clinical practice of transfusion medicine. With increased use, additional data are being generated to more fully characterize the effects of these interventions. Improved disinfection, blood diversion and bacterial detection have decreased, but not resolved the risk of bacterial contamination. Pathogen inactivation/reduction offers the potential for a further substantial decrease of the risk for transfusion of PC contaminated with bacteria.
Acute lung injury (ALI) during hematopoietic stem cell transplant (HSCT) is associated with substantial morbidity; however, the frequency of ALI in HSCT patients is poorly characterized. Platelets are postulated to play a critical role in the pathogenesis of ALI. Using a transfusion trial of pathogen inactivated platelet components (PC-Test) compared with conventional PC (Reference) populated with HSCT patients, data were reviewed by an adjudication panel to determine the frequency of ALI overall, by treatment groups, and key outcomes: PC exposure, ventilator-free days, and mortality. The diagnosis of ALI was based on American European Consensus Criteria. Of 645 patients who received PC over 28 days, 100 (15.5%) had clinically serious pulmonary adverse events, and 35 (5.4%) met criteria for ALI. Days of platelet support and number of platelet transfusions for patients with ALI were not significantly different from patients without ALI (P > .05). Mortality was greater for patients with ALI (57%) than those without (17%, P < .001) but not significantly different between treatment groups. For patients with ALI, the distributions of time to onset of mechanical ventilation were significantly different (P = .04). Patients supported with Reference PC were more likely to be ventilated sooner than patients receiving Test PC.