Shubhashish Bhakta

Dr. Shubhashish Bhakta


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in Sustainable Energy Technologies and Assessments
Verified
Journal Article
Closed access
SBShubhashish Bhakta
Shubhashish Bhakta
VMV. Mukherjee
V. Mukherjee

1 November 2015 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
SBShubhashish Bhakta
Shubhashish Bhakta
VMV. Mukherjee
V. Mukherjee
BSBinod Shaw
Binod Shaw
The aim of this paper is to present the techno-economic analysis and performance assessment of standalone photovoltaic (PV)/wind/hybrid energy system based on the simulation model for Lakshadweep islands of India where the islands' inhabitant depends on the use of power generation from diesel generator. In the present work, four Lakshadweep islands (namely, Andrott, Kavaratti, Kiltan, and Minicoy) are considered. The optimized system parameters are obtained from the monthly average solar radiation data, temperature data, and wind speed data for the three proposed renewable energy systems based on the assumed typical summer and winter load profiles. Based on an electrical performance of these three systems, the monthly average electrical power production, monthly average excess electrical production, monthly average unmet electrical load, monthly average converter output, and battery state of charge along with available battery input power over the year are detailed, analyzed, and compared. The techno-economic analysis is also performed among the systems to obtain the cost of energy (COE). The minimum COE for standalone PV-wind hybrid system in comparison with standalone PV or wind system is found to be $0.413 for Andrott island with 1 kW PV array, 1 kW wind turbine, eight numbers of battery, and 1 kW converter, while the COE is found to be $0.426 with 1.2 kW PV array, 1 kW wind turbine, eight numbers of battery, and 1 kW converter for Kavaratti, Kiltan, and Minicoy islands. Also, based on net present cost, it is shown that standalone PV-wind hybrid system is more economical as compared to either standalone PV or wind system.

1 October 2016 in Sustainable Energy Technologies and Assessments
Verified
Journal Article
Closed access
SBShubhashish Bhakta
Shubhashish Bhakta
VMV. Mukherjee
V. Mukherjee

1 December 2013 in Sustainable Energy Technologies and Assessments
Verified
Journal Article
Closed access
SBS. Bhattacharjee
S. Bhattacharjee
SBShubhashish Bhakta
Shubhashish Bhakta

1 January 2017 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
SBShubhashish Bhakta
Shubhashish Bhakta
VMV. Mukherjee
V. Mukherjee
This study examines the viability analysis of fixed-tilt and two axis tracking stand-alone photovoltaic (PV) power systems for electrical power generation in bio-climatic classification zones of the northeastern (NE) states of India where many remote villages are still un-electrified. Grid extension is not possible in many zones of the NE states of India because of the mountainous terrain. Therefore, as an alternative for un-electrified remote villages, the usage of stand-alone PV power systems may mitigate the power shortage problem. Based on the simulation model, the techno-economic analysis is carried out by using 22 years' of satellite-based monthly average solar radiation and temperature data. The typical load profile is also assumed for the purpose of analysis, which replicates the electrical appliances used by the end-users. The optimal fixed-tilt and optimal tracking PV system configuration along with optimal cost of energy (COE) is also obtained. The COE is found to be 0.383–0.497 $/kWh for the fixed-tilt PV system, and the same for the tracking PV system is obtained in the range of 0.523–0.732 $/kWh. From the fixed-tilt and tracking PV system, the monthly average electrical power, monthly average excess electrical power, monthly average unmet electrical load, monthly average inverter power, battery state of charge, and battery input power over the year are detailed, analyzed, and compared. Moreover, the capacity factor obtained in the case of a fixed-tilt PV system lies within the range of 14.2%–17.7% and the same is 17.6%–22.7% for the tracking PV system. Also, the findings of this study reveal detailed information regarding techno-economic and performance analysis of fixed-tilt and tracking PV power systems, which may help policy makers or investors to develop PV technology for the NE states of India.

1 March 2015 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
SBShubhashish Bhakta
Shubhashish Bhakta
VMV. Mukherjee
V. Mukherjee
BSB. Shaw
B. Shaw
This paper investigates the techno-economic analysis of standalone PV/wind hybrid system for remote household in North East (NE) region of India, where grid connectivity is not a feasible option. HOMER simulation software is used for sizing, optimization, and to perform the economical analysis of the hybrid system. Sensitivity analysis is carried out with solar radiation data, wind speed data, cost of PV and wind system for a 1 kW PV/wind hybrid system. The analysis is made on the assumption of an annual peak, scaled annual average, and the average load of 694 W, 3.95 kWh/day, and 0.165 kW, respectively, for a remote household. The optimal sizing, cost of electricity (COE), battery profile, and converter profile of PV/wind hybrid system for different NE states are presented in this paper. The outcome of this study shows that COE for the NE states is found to be in the range of 0.271–0.510 $/kWh, which is a acceptable margin and a hybrid PV/wind system will go a long way in addressing the shortage of power faced by a large section of the population on daily basis in the rural areas of the aforementioned region.