Delphine Vallot

Dr. Delphine Vallot


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2020 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
JTJan Taprogge
Jan Taprogge
FLFrancesca Leek
Francesca Leek
TSTino Schurrat
Tino Schurrat
JTJohannes Tran-Gia
Johannes Tran-Gia
DVDelphine Vallot
Delphine Vallot
SZSlimane Zerdoud
Slimane Zerdoud
Background: Differentiated thyroid cancer has been treated with radioiodine for almost 80 years, although controversial questions regarding radiation-related risks and the optimisation of treatment regimens remain unresolved. Multi-centre clinical studies are required to ensure recruitment of sufficient patients to achieve the statistical significance required to address these issues. Optimisation and standardisation of data acquisition and processing are necessary to ensure quantitative imaging and patient-specific dosimetry. Material and methods: A European network of centres able to perform standardised quantitative imaging of radioiodine therapy of thyroid cancer patients was set-up within the EU consortium MEDIRAD. This network will support a concurrent series of clinical studies to determine accurately absorbed doses for thyroid cancer patients treated with radioiodine. Five SPECT(/CT) systems at four European centres were characterised with respect to their system volume sensitivity, recovery coefficients and dead time. Results: System volume sensitivities of the Siemens Intevo systems (crystal thickness 3/8″) ranged from 62.1 to 73.5 cps/MBq. For a GE Discovery 670 (crystal thickness 5/8″) a system volume sensitivity of 92.2 cps/MBq was measured. Recovery coefficients measured on three Siemens Intevo systems show good agreement. For volumes larger than 10 ml, the maximum observed difference between recovery coefficients was found to be ± 0.02. Furthermore, dead-time coefficients measured on two Siemens Intevo systems agreed well with previously published dead-time values. Conclusions: Results presented here provide additional support for the proposal to use global calibration parameters for cameras of the same make and model. This could potentially facilitate the extension of the imaging network for further dosimetry-based studies.

12 May 2020 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
DVDelphine Vallot
Delphine Vallot
EPElena De Ponti
Elena De Ponti
SMSabrina Morzenti
Sabrina Morzenti
AGAnna Gramek
Anna Gramek
APAnna Pieczonka
Anna Pieczonka
OCOlivier Caselles
Olivier Caselles
Introduction: Quantitative imaging biomarkers are becoming usual in oncology for assessing therapy response. The harmonization of image quantitation reporting has become of utmost importance due to the multi-center trials increase. The NEMA image quality test is often considered for the evaluation of quantitation and is more accurate with a radioactive solid phantom that reduces variability. The goal of this project is to determine the level of variability among imaging centers if acquisition and imaging protocol parameters are left to the center’s preference while all other parameters are fixed including the scanner type. Methods: A NEMA-IQ phantom filled with radioactive 68Ge solid resin was imaged in five clinical sites throughout Europe. Sites reconstructed data with OSEM and BSREM algorithms applying the sites’ clinical parameters. Images were analyzed according with the NEMA-NU2-2012 standard using the manufacturer-provided NEMA tools to calculate contrast recovery (CR) and background variability (BV) for each sphere and the lung error (LE) estimation. In addition, a 18F-filled NEMA-IQ phantom was also evaluated to obtain a gauge for variability among centers when the sites were provided with identical specific instructions for acquisition and reconstruction protocol (the aggregate of data from 12 additional sites is presented). Results: The data using the 68Ge solid phantom showed no statistical differences among different sites, proving a very good reproducibility among the PET center models even if dispersion of data is higher with OSEM compared to BSREM. Furthermore, BSREM shows better CR and comparable BV, while LE is slightly reduced. Two centers exhibit significant differences in CR and BV values for the 18F NEMA NU2-2012 experiments; these outlier results are explained. Conclusion: The same PET system type from the various sites produced similar quantitative results, despite allowing each site to choose their clinical protocols with no restriction on data acquisition and reconstruction parameters. BSREM leads to lower dispersion of quantitative data among different sites. A solid radioactive phantom may be recommended to qualify the sites to perform quantitative imaging.

16 May 2023 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
MTMarie Terroir
Marie Terroir
CLChloé Lamesa
Chloé Lamesa
MKMehdi Krim
Mehdi Krim
LRLavinia Vija Racaru
Lavinia Vija Racaru
JTJean-Sébastien Texier
Jean-Sébastien Texier
FCFrédéric Courbon
Frédéric Courbon
Salivary gland cancers are rare tumors comprising a large group of heterogeneous tumors with variable prognosis. Their therapeutic management at a metastatic stage is challenging due to the lack of therapeutic lines and the toxicity of treatments. [177Lu]Lu-PSMA-617 (prostate-specific membrane antigen) is a vectored radioligand therapy (RLT) initially developed to treat castration-resistant metastatic prostate cancer with encouraging results in terms of efficacy and toxicity. Many malignant cells could be treated with [177Lu]Lu-PSMA-617 as long as they express PSMA as a consequence of androgenic pathway activation. RLT may be used when anti-androgen hormonal treatment has failed, particularly in prostate cancer. [177Lu]Lu-PSMA-617 has been proposed in certain salivary gland cancers, though the expression of PSMA is demonstrated by a significant uptake using [68Ga]Ga-PSMA-11 PET scan. This theranostic approach could be a new therapeutic option, warranting prospective investigation in a larger cohort. We review the literature on this subject and offer a clinical illustration of compassionate use in France as a perspective for administering [177Lu]Lu-PSMA-617 in salivary gland cancer.

2 April 2024 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
DVDelphine Vallot
Delphine Vallot
SBSéverine Brillouet
Séverine Brillouet
SPSéléna Pondard
Séléna Pondard
LVLavinia Vija
Lavinia Vija
JTJean-Sébastien Texier
Jean-Sébastien Texier
FCFrédéric Courbon
Frédéric Courbon
Background: Peptide receptor radionuclide therapy with 177Lu-DOTATATE is a recognized option for treating neuroendocrine tumors and has few toxicities, except for the kidneys and bone marrow. The bone marrow dose is generally derived from a SPECT/CT image-based method with four timepoints or from a blood-based method with up to 9 timepoints, but there is still no reference method. This retrospective single-center study on the same cohort of patients compared the calculated bone marrow dose administered with both methods using mono, bi- or tri-exponential models. For the image-based method, the dose was estimated using Planetdose© software. Pearson correlation coefficients were calculated. We also studied the impact of late timepoints for both methods. Results: The bone marrow dose was calculated for 131 treatments with the blood-based method and for 17 with the image-based method. In the former, the median absorbed dose was 15.3, 20.5 and 28.3 mGy/GBq with the mono-, bi- and tri-exponential model, respectively. With the image-based method, the median absorbed dose was 63.9, 41.9 and 60.8 with the mono-, bi- and tri-exponential model, respectively. Blood samples after 24h post-injection did not evidence any change in the absorbed bone marrow dose with the bi-exponential model. On the contrary, the 6-day post-injection timepoint was more informative with the image-based model. Conclusion: This study confirms that the estimated bone marrow dose is significantly lower with the blood-based method than with the image-based method. The blood-based method with a bi-exponential model proved particularly useful, without the need for blood samples after 24h post-injection. Nevertheless, this blood-based method is based on an assumption that needs to be more validated. The important difference between the two methods does not allow to determine the optimal one to estimate the true absorbed dose and further studies are necessary to compare with biological effects.

13 February 2024 in Irish Journal of Medical Science (1971 -)
Verified
Journal Article
Closed access
PDF file
DVDelphine Vallot
Delphine Vallot
ACAna Cavillon
Ana Cavillon
ALAmélie Lusque
Amélie Lusque
PIPhilippe Izard
Philippe Izard
GSGeneviève Salvignol
Geneviève Salvignol
RFRégis Fuzier
Régis Fuzier