As unique building blocks for advancing optoelectronics, 2D semiconducting transition metal dichalcogenides have garnered significant attention. However, most previously reported MoS2 photodetectors respond only to visible light with limited absorption, resulting in a narrow spectral response and low sensitivity. Here, a surrounding homojunction MoS2 photodetector featuring localized p‐type nitrogen plasma doping on the surface of n‐type MoS2 while preserving a high‐mobility underlying channel for rapid carrier transport is engineered. The establishment of p‐n homojunction facilitates the efficient separation of photogenerated carriers, thereby boosting the device's intrinsic detection performance. The resulting photoresponsivity is 6.94 × 104 A W−1 and specific detectivity is 1.21 × 1014 Jones @ 638 nm, with an optimal light on/off ratio of ≈107 at VGS = −27 V. Notably, the introduction of additional bands within MoS2 bandgap through nitrogen doping leads to an extrinsic broadband response to short‐wave infrared. The device exhibits a photoresponsivity of 34 A W−1 and a specific detectivity of up to 5.92 × 1010 Jones @ 1550 nm. Furthermore, the high‐performance broadband response is further demonstrated through imaging and integration with waveguides, paving the way for next generation of multifunctional imaging systems and high‐performance photonic chips.
2D molybdenum disulfide (MoS2)-based thin film transistors are widely used in biosensing, and many efforts have been made to improve the detection limit and linear range. However, in addition to the complexity of device technology and biological modification, the compatibility of the physical device with biological solutions and device reusability have rarely been considered. Herein, we designed and synthesized an array of MoS2 by employing a simple-patterned chemical vapor deposition growth method and meanwhile exploited a one-step biomodification in a sensing pad based on DNA tetrahedron probes to form a bio-separated sensing part. This solves the signal interference, solution erosion, and instability of semiconductor-based biosensors after contacting biological solutions, and also allows physical devices to be reused. Furthermore, the gate-free detection structure that we first proposed for DNA (BRCA1) detection demonstrates ultrasensitive detection over a broad range of 1 fM to 1 μM with a good linear response of R2 = 0.98. Our findings provide a practical solution for high-performance, low-cost, biocompatible, reusable, and bio-separated biosensor platforms.