Stefanie Werhahn

Dr. Stefanie Werhahn


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2024 in Die Kardiologie
Verified
Journal Article
Closed access
PDF file
SWStefanie Werhahn
Stefanie Werhahn
SKSebastian Kelle
Sebastian Kelle
EFEckart Fleck
Eckart Fleck

Verified
Journal Article
Open access
PDF file
SCShing Ching
Shing Ching
JLJeffrey Ji-Peng Li
Jeffrey Ji-Peng Li
SWStefanie Werhahn
Stefanie Werhahn
RBRebecca Elisabeth Beyer
Rebecca Elisabeth Beyer
MEMisael Estepa
Misael Estepa
PDPatrick Doeblin
Patrick Doeblin
Background: While left-bundle-branch-block-related contraction patterns as well as echocardiography-derived strain are variably associated with the volumetric response to cardiac resynchronization therapy (CRT), the role of CMR-derived strain parameters is unexplored. Methods: A total of 50 patients receiving CRT implantation were retrospectively analyzed, all of whom had undergone CMR imaging within one year before, and echocardiography within 6 months before and 6–12 months after CRT implantation. We assessed CMR-derived morphological and functional parameters with regard to the echocardiographic response, defined as a reduction in the left ventricular end-systolic volume of ≥15%. Results: Among the standard CMR parameters, the indexed right ventricular volumes in end-diastole (RVEDVi) (74.5 ± 19.5 vs. 94.8 ± 30.2 mL/m2, p = 0.006) and end-systole (RVESVi) (43.2 ± 13.3 vs. 61.6 ± 28.8 mL/m2, p = 0.003), as well as the left atrial (LA) area (24.8 ± 3.5 vs. 30.4 ± 9.5 cm2, p = 0.020), differed significantly between CRT responders and non-responders. In strain analysis, CRT responders showed a significantly better LA global longitudinal strain (GLS) (25.1 ± 10.4 vs. 15.3 ± 10.5, p = 0.002), LA global circumferential strain (GCS) (27.9 ± 14.7 vs. 17.1 ± 13.1%, p = 0.012), RV GLS (−25.0 ± 6.5 vs. −18.9 ± 7.6%, p = 0.004) and RV free wall strain (−31.1 ± 7.9 vs. −24.9 ± 9.5, p = 0.017). Conclusions: CMR-derived peak septal circumferential strain and RVEDVi correlated with the echocardiographic volumetric response to CRT at 6–12 months.

11 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
AKAndreas Kind
Andreas Kind
HPHelena Franziska Pernice
Helena Franziska Pernice
GBGina Barzen
Gina Barzen
JGJan Wolfgang Gröschel
Jan Wolfgang Gröschel
ASAurelian Schumacher
Aurelian Schumacher
SSSebastian Spethmann
Sebastian Spethmann
Wearable sensors enable continuous recording of electrocardiographic, photoplethysmographic, and inertial signals and have accelerated the development of digital biomarkers in cardiovascular medicine. Transthyretin amyloidosis (ATTR) is a progressive multisystem disease characterized by arrhythmia, conduction disturbances, hemodynamic impairment, autonomic dysfunction, and gait abnormalities, making it theoretically suitable for multimodal wearable monitoring. This review summarizes current knowledge on wearable applications in amyloidosis with ATTR serving as an illustrative case, evaluates the plausibility of extrapolating signal-based biomarkers from related cardiovascular and neurological cohorts, and outlines methodological and implementation challenges. ATTR-specific data remain limited to small observational studies, mainly on long-term rhythm monitoring and supervised functional assessment. More comprehensive findings support the extraction of metrics such as atrial fibrillation burden, activity patterns, gait variability, and heart rate variability. However, ATTR-related structural remodeling and high arrhythmia burden may distort conventional digital biomarkers, necessitating disease-specific preprocessing and prospective validation. Wearable monitoring in ATTR is technically feasible and biologically plausible but remains investigational. Before routine integration into care pathways can be recommended, standardized, phenotype-stratified studies are needed that link wearable-derived characteristics to assessed clinical outcomes.

13 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
SCShing Ching
Shing Ching
JLJeffrey Ji-Peng Li
Jeffrey Ji-Peng Li
SWStefanie Werhahn
Stefanie Werhahn
RBRebecca Elisabeth Beyer
Rebecca Elisabeth Beyer
MEMisael Estepa
Misael Estepa
PDPatrick Doeblin
Patrick Doeblin
Background: While left-bundle-branch-block-related contraction patterns as well as echocardiography derived strain are variably associated with volumetric response to cardiac resynchronization therapy (CRT), the role of CMR-derived strain parameters is unexplored. Methods: 50 patients receiving CRT implantation were retrospectively analysed, all of which had undergone CMR imaging within one year before, and echocardiography within 6 months before and 6-12 months after CRT implantation. We assessed CMR-derived morphological and functional parameters with regard to echocardiographic response, defined as reduction of left ventricular end-systolic volume ≥15%. Results: Among standard CMR parameters, indexed right ventricular volumes in end-diastole (RVEDVi) (74.5 ±19.5 vs. 94.8 ±30.2 ml/m², P=.006) and end-systole (RVESVi) (43.2 ±13.3 vs. 61.6 ±28.8 ml/m², P=.003) as well as left atrial (LA) area (24.8 ±3.5 vs. 30.4 ±9.5 cm², P=.020) differed significantly between CRT responders and non-responders. In strain analysis, CRT responders showed significantly better LA global longitudinal strain (GLS) (25.1 ±10.4 vs. 15.3 ±10.5, P=.002), LA global circumferential strain (GCS) (27.9 ±14.7 vs. 17.1 ±13.1%, P=.012), RV GLS (-25.0 ±6.5 vs. -18.9 ±7.6%, P=.004) and RV free wall strain (-31.1 ±7.9 vs. -24.9 ±9.5, P=.017). Conclusions: CMR-derived peak septal circumferential strain and RVEDVi correlated with echocardiographic volumetric response to CRT at 6-12 months.

17 March 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
AKAndreas Kind
Andreas Kind
HPHelena Franziska Pernice
Helena Franziska Pernice
GBGina Barzen
Gina Barzen
JGJan Wolfgang Gröschel
Jan Wolfgang Gröschel
ASAurelian Eroni Schumacher
Aurelian Eroni Schumacher
SSSebastian Spethmann
Sebastian Spethmann
Wearable sensors enable continuous recording of electrocardiographic, photoplethys-mographic, and inertial signals and have accelerated the development of digital bi-omarkers in cardiovascular medicine. Transthyretin amyloidosis (ATTR) is a progressive multisystem disease characterized by arrhythmia, conduction disturbances, hemody-namic impairment, autonomic dysfunction, and gait abnormalities, making it theoreti-cally suitable for multimodal wearable monitoring. This review summarizes current knowledge on wearable applications in ATTR, evaluates the plausibility of extrapolating signal-based biomarkers from related cardiovascular and neurological cohorts, and out-lines methodological and implementation challenges. ATTR-specific data remain limited to small observational studies, mainly on long-term rhythm monitoring and supervised functional assessment. More comprehensive findings support the extraction of metrics such as atrial fibrillation burden, activity patterns, gait variability, and heart rate var-iability. However, ATTR-related structural remodeling and high arrhythmia burden may distort conventional digital biomarkers, necessitating disease-specific preprocessing and prospective validation. Wearable monitoring in ATTR is technically feasible and biologically plausible but remains investigational. Before routine integration into care pathways can be recommended, standardized, phenotype-stratified studies are needed that link wearable-derived characteristics to assessed clinical outcomes.