This in-vitro study aimed to evaluate the effects of different polishing systems on the surface roughness and discoloration of various composite resins, and to assess the effectiveness of repolishing procedures in reducing discoloration. Four different composite resins (giomer, nanohybrid, nanoceramic, microhybrid) were polished using various systems. Surface roughness was evaluated using mechanical profilometer, Atomic Force Microscopy (AFM). Surface morphology was examined by Scanning Electron Microscopy (SEM). Samples were immersed in a coffee solution for staining, followed by repolishing. Color change (ΔE) values were recorded. Surface roughness and discoloration varied based on the composite type and polishing system. The smoothest surface was observed in the nanohybrid composite polished with OptiDisc (Ra: 0.59), while the roughest surface was seen in the nanoceramic composite polished with Lucida (Ra: 1.70). The highest discoloration occurred in the giomer with Enhance PoGo, while Twist Dia produced the most stain-resistant surfaces (p = 0.008). Repolishing with the OptiDisc significantly reduced discoloration, with ΔE values falling within clinically acceptable limits only in this group (p = 0.00671). Multi-step polishing systems, those containing aluminum oxide were more effective in achieving smoother surfaces and better color stability. Results varied according to the composite material and the polishing system used. This study emphasizes that different polishing systems may lead to differences that could potentially affect the clinical performance and aesthetic longevity of composite resins.
22 September 2022 in Odovtos - International Journal of Dental Sciences
Obesity is a chronic disease that may be related to caries, periodontitis, xerostomia, and dental erosion, as well as increasing morbidity and mortality. The aim of this study was to evaluate the plaque index (Silness & Löe, 1964), the gingival index (Löe & Silness, 1963), and the oral health-related quality of life (OHRQoL) in obese patients. The study included 45 extremely obese, 45 obese, and 45 normal-weight individuals between the ages of 18 and 58. The plaque index and gingival index of the individuals were determined by clinical examination by probing. In addition, the Oral Health Impact Profile-14 (OHIP-14) questionnaire was used for the OHRQoL. The IBM SPSS Statistic 22.0 software program was used for the statistical evaluation of the study data. The plaque index and gingival index values were statistically higher in obese compared to normal weight individuals (p0.05). There was no statistically significant difference between the OHIP-14 total scores of the groups (p>0.05). Increased apparent plaque index and gingival index values in obese patients may adversely affect periodontal health.
26 December 2019 in İstanbul Tıp Fakültesi Dergisi
This study aimed to compare the effects of the collagen-BioAggregate mixture (CBA-M) and collagen-BioAggregate composite (CBA-C) sponge as a scaffolding material on the reparative dentin formation. CBA-C sponge (10:1 w/w) was obtained and characterized by Scanning Electron Microscopy (SEM) and Mercury Porosimetry. Cytotoxicity of the CBA-C sponge was tested by using the L929 mouse fibroblast cell line. Dental pulp stem cells (DPSCs) were isolated from the pulp tissue of sheep teeth and characterized by flow cytometry for the presence of mesenchymal stem cell marker, CD44. The osteogenic differentiation capability of isolated DPSCs was studied by Alizarin Red staining. The cells were then used to study for the compatibility of CBA-C sponge with cell proliferation and calcium phosphate deposition. The effect of CBA-C sponge and CBA-M on the induction of dentin regeneration was studied in the perforated teeth of sheep for the eight-week period. All the analyses were performed with appropriate statistical hypothesis tests. CBA-C sponge was found to be biocompatible for DPSCs. The DPSCs seeded on the CBA-C sponge were able to differentiate into the osteoblastic lineage and deposit calcium phosphate crystals in vitro. Reparative dentin formation was observed after the second week in the CBA-C sponge applied group. At the end of eight weeks, a complete reparative dentin structure was formed in the CBA-C sponge applied group, whereas necrotic tissue residues were observed in groups treated with the CBA-M. CBA-C sponge represents a better microenvironment for reparative dentin formation probably due to maintaining DPSCs and allowing their osteogenic differentiation and thus calcium phosphate deposition.
Background: The effects of whitening toothpastes containing nanohydroxyapatite on the surfaces of restorative materials are not well known. This study evaluated the changes in surface roughness and color of coffee-stained restorative materials after brushing with nanohydroxyapatite and other whitening toothpastes. Methods: Disc-shaped specimens were formed using microhybrid, nanohybrid, and supra-nano-filled composite (n = 30) and stained with a coffee solution. A brushing simulation was applied with toothpastes containing nanohydroxyapatite (Dentiste Plus White), perlite (Signal White System) and hydrogen peroxide (Colgate Optic White) for 7, 15, and 30 days. Color and surface roughness measurements were taken before and after brushing. Color change (∆E00) was calculated using the CIEDE2000 system. Results: Supra-nano-filled composite-Dentiste Plus White, supra-nano-filled composite-Colgate Optic White, and nanohybrid composite-Signal White System were the groups with the greatest color change observed on the 7th, 15th, and 30th days, respectively. The smallest color change was seen in the microhybrid composite-Signal White System, microhybrid composite-Dentiste Plus White, and nanohybrid composite-Dentiste Plus White groups on the 7th, 15th, and 30th days, respectively. No significant surface roughness changes were observed in the nanohybrid composite-Dentiste Plus White, supra-nano-filled composite-Colgate Optic White, supra-nano-filled composite-Dentiste Plus White, or supra-nano-filled composite-Signal White System groups. Conclusions: Whitening toothpaste containing nanohydroxyapatite provided a high degree of color change in the short term and did not create significant surface roughness in nanohybrid or supra-nano-filled composites.
26 April 2023 in Odovtos - International Journal of Dental Sciences
To examine the colour change and surface roughness of giomer, microhybrid composite and nanohybrid composite after brushing with whitening toothpastes. Disc-shaped samples of giomer, microhybrid composite and nanohybrid composite were divided into three subgroups(n=10), with the initial colour measured with a spectrophotometer and the surface roughness measured with a mechanical profilometer. The samples, which were immersed in coffee solution were brushed once a day with whitening toothpastes (Opalescence Cool Mint (OCM), Colgate Optic White Extra Power (COW) and Signal White Now Gold (SWN)) for 12 days. Colour change and surface roughness were measured again after the colouring-brushing cycle. All of the analyses were performed using appropriate statistical hypothesis tests. The highest increase in surface roughness was seen in the microhybrid composite group applied with SWN (p<0.05). The group with the least increase was the giomer group applied with SWN (p<0.05). While the least colour change was observed in the COW applied nanohybrid composite group (∆E00=1,814), the most colour change occurred in the COW applied giomer group (∆E00=5.943). After the use of whitening toothpastes, the roughness of giomer, microhybrid composite and nanohybrid composite surfaces was increased and a colour change above the clinically accepted value was observed.
21 December 2022 in Journal of Advanced Oral Research
Aim: Recently, although studies have shown that biomaterials containing graphene oxide (GO) in biomedicine stand out for their positive effects, the effect of GO on dental tissues when used with dental materials is not well known. The aim of this study was an evaluation of the cytotoxic effects of GO on gingival fibroblasts when it is combined in two different ratios with Mineral Trioxide Aggregate (MTA). Materials and Methods: In this in-vitro study, a homogenous mixture of adding +0.1 weight (wt)% and +0.3 wt% GO to Angelus MTA was created (two experimental groups) and compared with pure Angelus MTA and negative control groups. The materials were mixed according to the manufacturer’s instructions, and Teflon molds were used to form 24 disc-shaped samples for each group. The samples were divided into groups according to the simple random sampling method. The cytotoxic effect of samples was determined on gingival fibroblast cells by using the MTT test, and total oxidant status (TOS) and total antioxidant capacity (TAC) kits in 24 and 72 hours. The data were statistically analyzed using one-way ANOVA and Tukey tests. Results: A significant difference was found between the material-applied groups and the control group at the TAC 24 and 72 hours and between the groups containing GO and the control group at the MTT 72 hours and TAC and TOS 24 and 72 hours ( p < .05). Conclusion: The addition of GO to MTA increased the dose and time-based toxicity and oxidant amount, and decreased antioxidant capacity.