Background: Cone beam computed tomography (CBCT) is essential for correcting and verifying patient position before radiation therapy. However, it poses additional radiation exposure during CBCT scans. Therefore, this study aimed to evaluate radiological safety for the human body through dose assessment for CBCT.Materials and Methods: For CBCT dose assessment, the depth dose was evaluated using a cheese phantom, and the dose in the orbital area was evaluated using a human body phantom self-fabricated with a three-dimensional printer.Results and Discussion: The evaluation of radiation doses revealed maximum doses of 14.14 mGy and minimum doses of 6.12 mGy for pelvic imaging conditions. For chest imaging conditions, the maximum doses were 4.82 mGy, and the minimum doses were 2.35 mGy. Head imaging conditions showed maximum doses of 1.46 mGy and minimum doses of 0.39 mGy. The eyeball doses using a human body phantom model averaged at 2.11 mGy on the left and 2.19 mGy on the right. The depth dose ranged between 0.39 mGy and 14.14 mGy, depending on the change in depth for each imaging mode, and the average dose in the orbit area using a human body phantom was 2.15 mGy.Conclusion: Based on the experimental results, CBCT did not significantly affect the radiation dose. However, it is important to maintain a minimal radiation dose to optimize radiation protection following the as low as reasonable achievable principle.
Radiation therapy is a crucial treatment method that delivers a high dose of radiation to localized areas. Therefore, ensuring the accuracy of the radiation dose from the radiation generator is essential. Alanine dosimetry offers the advantage of being equivalent to water and tissue and is thus a valuable tool for estimating radiation doses in the human body. In this study, we aimed to assess the feasibility of utilizing electron paramagnetic resonance (EPR)/alanine dosimetry for quality control of medical linear accelerators (LINACs). The EPR signal and slope of the dose-response curve were compared with the number of alanine dosimeters per dose using a 10 MV linear accelerator, and the measurement uncertainty was evaluated. The signal increased by approximately 0.03 per 1 Gy per count, in conjunction with the slope of the dose-response curve. The measurement uncertainty, estimated based on the synthesis of eight numerical factors of the uncertainty propagation law, was approximately 2.49–4.19% (k = 1). The findings of this study suggest that the EPR/alanine dosimetry system can be reliably applied for quality control of 10 MV photon beams under the investigated experimental conditions.