Deniz Birlik Kayı

Dr. Deniz Birlik Kayı

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2026 in Buildings
Verified
Journal Article
Open access
PDF file
DKDeniz Birlik Kayı
Deniz Birlik Kayı
BBBeyhan Bayhan
Beyhan Bayhan
GÖGökhan ÖZDEMİR
Gökhan ÖZDEMİR
This paper aims to quantify the change in seismic response of a reinforced concrete (RC) building retrofitted by the seismic isolation technique when reinforcement corrosion is considered. In this regard, an 8-story RC building that possesses the characteristics of the existing fixed-base building stock in Türkiye has been identified and hypothetically retrofitted with lead rubber bearings (LRBs). In the numerical models, four different corrosion scenarios to represent the spatial distribution of corrosion on the frame elements of the superstructure and three different corrosion levels considering the mass losses (5, 10 and 20%) due to corrosion are considered; the corresponding reductions in (i) the cross-sectional areas of both the longitudinal and transverse reinforcements and (ii) the mechanical properties of steel and concrete are taken into account. Code-based bidirectional nonlinear response history analyses (NRHAs) are performed by considering the nonlinearity not only in the seismic isolation system but also in the superstructure. Furthermore, LRBs are represented by a force–displacement relation that enables modeling of the deterioration in strength of isolators due to lead core heating during cyclic motion. The results revealed that the spatial distribution of the corrosion is highly effective in amplification of inter-story drift ratios (ISDRs), which can be in the order of 2-fold depending on the level of mass loss. It is found that the seismic isolation technique is still effective in protecting the superstructure against earthquakes even though there is a corrosion problem in frame members.

28 April 2026 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
DKDeniz Birlik Kayı
Deniz Birlik Kayı
BBBeyhan Bayhan
Beyhan Bayhan
GÖGökhan ÖZDEMİR
Gökhan ÖZDEMİR
This paper investigates the change in seismic demands of a reinforced concrete (RC) building retrofitted by seismic isolation technique, due to change in superstructure characteristics. First, an RC building that possesses the general characteristics of fixed-base building stock in Türkiye is identified. Then, it is retrofitted by means of Lead Rubber Bearings (LRBs) and subjected to bidirectional ground motion excitations through nonlinear response history analyses (NRHA). Concrete compressive strength, dimensions of both beams and columns, and first story height are the parameters considered in the analyses. Two different numerical models are established by considering both linear and nonlinear element definitions for the superstructure. In either case, LRBs are represented by deteriorating hysteretic force-displacement relations that consider the effect of heating in the lead core during cyclic motion. Results indicate that increasing the beam dimensions is the most effective approach in retrofitting of the analyzed structural model to reduce inter-story drift ratios (ISDRs). An increase in beam dimensions led to an approximately 30% reduction in ISDRs, while enhancements in concrete compressive strength and dimensions of columns yielded reductions of nearly 20%. The elastic superstructure model may lead to underestimated ISDRs by more than 1.5 folds compared to its nonlinear counterpart.