David W. Inglis

Dr. David W. Inglis

School of Engineering, Macquarie University, Sydney, NSW 2109, Australia
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2006 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
JDJohn A. Davis
John A. Davis
David W. InglisDavid W. Inglis
David W. Inglis
KMKeith J. Morton
Keith J. Morton
DLDavid A. Lawrence
David A. Lawrence
LHLotien R. Huang
Lotien R. Huang
RARobert Austin
Robert Austin
We show the fractionation of whole blood components and isolation of blood plasma with no dilution by using a continuous-flow deterministic array that separates blood components by their hydrodynamic size, independent of their mass. We use the technology we developed of deterministic arrays which separate white blood cells, red blood cells, and platelets from blood plasma at flow velocities of 1,000 μm/sec and volume rates up to 1 μl/min. We verified by flow cytometry that an array using focused injection removed 100% of the lymphocytes and monocytes from the main red blood cell and platelet stream. Using a second design, we demonstrated the separation of blood plasma from the blood cells (white, red, and platelets) with virtually no dilution of the plasma and no cellular contamination of the plasma.

17 March 2006 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
David W. InglisDavid W. Inglis
David W. Inglis
JDJohn A. Davis
John A. Davis
RARobert H. Austin
Robert H. Austin
JSJames C. Sturm
James C. Sturm
The fractionation of small particles in a liquid based on their size in a micropost array by deterministic lateral displacement was recently demonstrated with unprecedented resolution (L. R. Huang, E. C. Cox, R. H. Austin and J. C. Sturm, Science, 2004, 304, 987–990, ). In this paper, we present a model of how the critical particle size for fractionation depends on the micropost geometry, depending specifically on the gap between posts, the offset of posts in one row with respect to another, and whether the fluid is driven by hydrodynamics or by electroosmosis. In general the critical particle diameter is much smaller than the gap, which prevents clogging. The model is supported by data with particles from 2.3 to 22 µm.

22 November 2004 in Applied Physics Letters
Verified
Journal Article
Closed access
David W. InglisDavid W. Inglis
David W. Inglis
RRR. Riehn
R. Riehn
RAR. H. Austin
R. H. Austin
JSJ. C. Sturm
J. C. Sturm
We present a continuous-flow microfluidic device that enables cell by cell separation of cells selectively tagged with magnetic nanoparticles. The cells flow over an array of microfabricated magnetic stripes, which create a series of high magnetic field gradients that trap the magnetically labeled cells and alter their flow direction. The process was observed in real time using a low power microscope. The device has been demonstrated by the separation of leukocytes from whole human blood.

26 August 2020 in ACS Nano
Verified
Journal Article
Closed access
AHAxel Hochstetter
Axel Hochstetter
RVRohan Vernekar
Rohan Vernekar
RARobert H. Austin
Robert H. Austin
CGClaudia Gärtner
Claudia Gärtner
JBJason P. Beech
Jason P. Beech
David W. InglisDavid W. Inglis
David W. Inglis

17 July 2009 in Small
Verified
Journal Article
Closed access
PDF file
BSBradley R. Smith
Bradley R. Smith
David W. InglisDavid W. Inglis
David W. Inglis
BSBjornar Sandnes
Bjornar Sandnes
JRJames R. Rabeau
James R. Rabeau
Andrei ZvyaginAndrei Zvyagin
Andrei Zvyagin
TPTaras Plakhotnik
Taras Plakhotnik

7 November 2019 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
TZTianlong Zhang
Tianlong Zhang
ZHZhen-Yi Hong
Zhen-Yi Hong
Shiyang TangShiyang Tang
Shiyang Tang
WLWeihua Li
Weihua Li
David W. InglisDavid W. Inglis
David W. Inglis
Ming LiMing Li
Ming Li
Sub-micrometer particles (0.10–1.0 μm) are of great significance to study, e.g., microvesicles and protein aggregates are targets for therapeutic intervention, and sub-micrometer fluorescent polystyrene (PS) particles are used as probes for diagnostic imaging. Focusing of sub-micrometer particles – precisely control over the position of sub-micrometer particles in a tightly focused stream – has a wide range of applications in the field of biology, chemistry and environment, by acting as a prerequisite step for downstream detection, manipulation and quantification. Microfluidic devices have been attracting great attention as desirable tools for sub-micrometer particle focusing, due to their small size, low reagent consumption, fast analysis and low cost. Recent advancements in fundamental knowledge and fabrication technologies have enabled microfluidic focusing of particles at sub-micrometer scale in a continuous, label-free and high-throughput manner. Microfluidic methods for the focusing of sub-micrometer particles can be classified into two main groups depending on whether an external field is applied: 1) passive methods, which utilize intrinsic fluidic properties without the need of external actuation, such as inertial, deterministic lateral displacement (DLD), viscoelastic and hydrophoretic focusing; and 2) active methods, where external fields are used, such as dielectrophoretic, thermophoretic, acoustophoretic and optical focusing. This article mainly reviews the studies on the focusing of sub-micrometer particles in microfluidic devices over the past 10 years. It aims to bridge the gap between the focusing of micrometer and nanometer scale (1.0–100 nm) particles and to improve the understanding of development progress, current advances and future prospects in microfluidic focusing techniques.