Velichko Atanasov

Dr. Velichko Atanasov


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
Velichko AtanasovVelichko Atanasov
Velichko Atanasov
Dimo Georgiev StoilovDimo Georgiev Stoilov
Dimo Georgiev Stoilov
Nikolina Stefanova PetkovaNikolina Stefanova Petkova
Nikolina Stefanova Petkova
NNNikola Nedelchev Nikolov
Nikola Nedelchev Nikolov
This paper presents a comprehensive life-cycle analysis of distribution transformers, based on realized measurements of the increased power losses as a result of their long-term service under real-world conditions. The study is based on aggregated measured data from extensive fleets of oil-immersed distribution transformers characterized by diverse designs, manufacturing vintages, and service lives. The evolution of no-load losses and short-circuit losses is analyzed as a function of operational duration, structural characteristics, and the specific technologies employed for windings and magnetic core construction. Statistical models describing the variation in these losses are presented, highlighting the limitations of the static assumptions commonly utilized in power distribution network planning. On this basis, an approximation of the time evolution of the transformer’s total power and energy losses is proposed as appropriate for implementation in a life-cycle analysis model. Furthermore, the impacts of thermal loading and abnormal operating conditions—such as unbalanced loads, frequent short circuits, and repeated overheating of the transformer oil—are analyzed as drivers of accelerated transformer aging. These effects are integrated into a unified life-cycle framework, enabling the quantitative assessment of loss variations and their associated operational expenditures (OPEX). A numerical example is provided to evaluate the cost-effectiveness of “repair vs. replacement” scenarios, utilizing a discounted cash flow analysis that incorporates a carbon component. The findings establish a methodological foundation for a broader assessment of technical condition and energy performance, identifying the optimal intervention point for repair or replacement to support decision-making for Distribution System Operators (DSOs) amidst increasing requirements for efficiency and decarbonization.

30 July 2026 in Energies
Verified
Journal Article
Open access
PDF file
Velichko AtanasovVelichko Atanasov
Velichko Atanasov
Dimo Georgiev StoilovDimo Georgiev Stoilov
Dimo Georgiev Stoilov
Nikolina Stefanova PetkovaNikolina Stefanova Petkova
Nikolina Stefanova Petkova
EGElitsa Gieva
Elitsa Gieva
The increasing penetration of inverter-based renewable energy sources and the growing share of underground cable lines significantly modify the frequency-dependent characteristics of medium-voltage distribution networks, increasing the risk of harmonic resonance. Existing resonance studies are often based on detailed electromagnetic models that are difficult to apply during routine distribution network planning and operation. This paper proposes an engineering-oriented methodology for the preliminary assessment of harmonic resonance risk using an equivalent lumped-parameter model that incorporates overhead and cable lines, transformer inductance, photovoltaic generation, and the short-circuit strength of the supplying system. The methodology is applied to a representative 20 kV distribution network to investigate the influence of cable penetration, photovoltaic capacity, transformer loading, and grid strength on resonance conditions. The results show that increasing network capacitance and reducing short-circuit power shift the resonance frequency toward lower-order harmonics, increasing the probability of harmonic amplification. The highest resonance risk is observed under the combined conditions of high photovoltaic generation, low transformer loading, and weak-grid conditions. Unlike detailed electromagnetic simulation models, the proposed methodology enables rapid engineering assessment using parameters readily available to distribution system operators, thereby supporting network planning and operational decision-making in medium-voltage distribution systems with high photovoltaic penetration.

26 May 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Velichko AtanasovVelichko Atanasov
Velichko Atanasov
Dimo Georgiev StoilovDimo Georgiev Stoilov
Dimo Georgiev Stoilov
Nikolina Stefanova PetkovaNikolina Stefanova Petkova
Nikolina Stefanova Petkova
EGElitsa Gieva
Elitsa Gieva
The increasing penetration of inverter-based renewable energy sources and the growing share of cable sections in modern power distribution networks significantly modify the frequency-dependent characteristics of power systems and increase the risk of harmonic resonance phenomena. This issue is particularly relevant for highly branched medium-voltage distribution networks with combined overhead and cable feeders, where the changing ratio between inductive and capacitive parameters may lead to resonance conditions, increased harmonic distortion, maloperation of protection systems, equipment overloading, and deterioration of power quality. This paper presents an analysis of harmonic resonance in 20 kV distribution networks using an equivalent model based on lumped inductive and capacitive parameters. The proposed model takes into account the influence of overhead and cable lines, transformer inductance, photovoltaic inverters, and the short-circuit power of the supplying substation. A real-case example of a medium-voltage distribution network with combined overhead and cable sections and integrated photovoltaic generation is also presented. Frequency-domain analysis is performed under different operating conditions, including variations in cable line length, increasing installed photovoltaic capacity, and reduction of the short-circuit power of the supplying system. The obtained results demonstrate that increasing the equivalent network capacitance and weakening the supplying system shift the resonance frequency toward lower-order harmonics and increase the likelihood of harmonic voltage and current amplification. It is established that the most unfavorable operating conditions occur under the combined presence of high photovoltaic generation, low daytime loading of distribution transformers, and limited short-circuit power at the supplying substation. The proposed approach can be used as an engineering method for preliminary assessment of harmonic resonance risk during the planning and operation of modern power distribution networks.