Jeffrey Miner

Dr. Jeffrey Miner

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2018 in Arthritis Research & Therapy
Verified
Journal Article
Open access
PDF file
TFTahzeeb Fatima
Tahzeeb Fatima
CMCushla McKinney
Cushla McKinney
TMTanya J. Major
Tanya J. Major
LSLisa Stamp
Lisa Stamp
NDNicola Dalbeth
Nicola Dalbeth
JMJeffrey Miner
Jeffrey Miner
Ferritin positively associates with serum urate and an interventional study suggests that iron has a role in triggering gout flares. The objective of this study was to further explore the relationship between iron/ferritin and urate/gout. European (100 cases, 60 controls) and Polynesian (100 cases, 60 controls) New Zealand (NZ) males and 189 US male cases and 60 male controls participated. The 10,727 participants without gout were from the Jackson Heart (JHS; African American = 1260) and NHANES III (European = 5112; African American = 4355) studies. Regression analyses were adjusted for age, sex, body mass index and C-reactive protein. To test for a causal relationship between ferritin and urate, bidirectional two-sample Mendelian randomization analysis was performed. Serum ferritin positively associated with gout in NZ Polynesian (OR (per 10 ng ml− 1 increase) = 1.03, p = 1.8E–03) and US (OR = 1.11, p = 7.4E–06) data sets but not in NZ European (OR = 1.00, p = 0.84) data sets. Ferritin positively associated with urate in NZ Polynesian (β (mg dl− 1) = 0.014, p = 2.5E–04), JHS (β = 0.009, p = 3.2E–05) and NHANES III (European β = 0.007, p = 5.1E–11; African American β = 0.011, p = 2.1E–16) data sets but not in NZ European (β = 0.009, p = 0.31) or US (β = 0.041, p = 0.15) gout data sets. Ferritin positively associated with the frequency of gout flares in two of the gout data sets. By Mendelian randomization analysis a one standard deviation unit increase in iron and ferritin was, respectively, associated with 0.11 (p = 8E–04) and 0.19 mg dl− 1 (p = 2E–04) increases in serum urate. There was no evidence for a causal effect of urate on iron/ferritin. These data replicate the association of ferritin with serum urate. Increased ferritin levels associated with gout and flare frequency. There was evidence of a causal effect of iron and ferritin on urate.

2 May 2018 in Arthritis Research & Therapy
Verified
Journal Article
Open access
PDF file
SFStéphanie Fabre
Stéphanie Fabre
PCPierre Clerson
Pierre Clerson
JLJean-Marie Launay
Jean-Marie Launay
JGJean-François Gautier
Jean-François Gautier
TVTiphaine Vidal-Trecan
Tiphaine Vidal-Trecan
TBThomas Bardin
Thomas Bardin
The uric acid (UA) level in patients with gout is a key factor in disease management and is typically measured in the laboratory using plasma samples obtained after venous puncture. This study aimed to assess the reliability of immediate UA measurement with capillary blood samples obtained by fingertip puncture with the HumaSensplus point-of-care meter. UA levels were measured using both the HumaSensplus meter in the clinic and the routine plasma UA method in the biochemistry laboratory of 238 consenting diabetic patients. HumaSensplus capillary and routine plasma UA measurements were compared by linear regression, Bland-Altman plots, intraclass correlation coefficient (ICC), and Lin’s concordance coefficient. Values outside the dynamic range of the meter, low (LO) or high (HI), were analyzed separately. The best capillary UA thresholds for detecting hyperuricemia were determined by receiver operating characteristic (ROC) curves. The impact of potential confounding factors (demographic and biological parameters/treatments) was assessed. Capillary and routine plasma UA levels were compared to reference plasma UA measurements by liquid chromatography-mass spectrometry (LC-MS) for a subgroup of 67 patients. In total, 205 patients had capillary and routine plasma UA measurements available. ICC was 0.90 (95% confidence interval (CI) 0.87–0.92), Lin’s coefficient was 0.91 (0.88–0.93), and the Bland-Altman plot showed good agreement over all tested values. Overall, 17 patients showed values outside the dynamic range. LO values were concordant with plasma values, but HI values were considered uninterpretable. Capillary UA thresholds of 299 and 340 μmol/l gave the best results for detecting hyperuricemia (corresponding to routine plasma UA thresholds of 300 and 360 μmol/l, respectively). No significant confounding factor was found among those tested, except for hematocrit; however, this had a negligible influence on the assay reliability. When capillary and routine plasma results were discordant, comparison with LC-MS measurements showed that plasma measurements had better concordance: capillary UA, ICC 0.84 (95% CI 0.75–0.90), Lin’s coefficient 0.84 (0.77–0.91); plasma UA, ICC 0.96 (0.94–0.98), Lin’s coefficient 0.96 (0.94–0.98). UA measurements with the HumaSensplus meter were reasonably comparable with those of the laboratory assay. The meter is easy to use and may be useful in the clinic and in epidemiologic studies.