Yang Xiu

Dr. Yang Xiu


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
BTBo Tang
Bo Tang
GGGangfeng Gao
Gangfeng Gao
XXXiangwu Xia
Xiangwu Xia
YXYang Xiu
Yang Xiu
The integrated energy system effectively improves the comprehensive utilization of energy through cascade utilization and coordinated scheduling of various types of energy. Based on the independent integrated energy system, the thermal network interaction between different load characteristic regions is introduced, requiring a minimum thermal grid construction cost, CCHP investment operation cost and carbon emission tax as the comprehensive optimization targets, and making overall optimization to the configuration and operation of the multi-region integrated energy systems. This paper focuses on the planning of equipment capacity of multi-region integrated energy system based on a CCHP system and heat network. Combined with the above comprehensive target and heat network model, a mixed integer linear programming model for a multi-region CCHP system capacity collaborative optimization configuration is established. The integrated energy system, just a numerical model solved with the LINGO software, is presented. Taking a typical urban area in Shanghai as an example, the simulation results show that the integrated energy system with multi-zone heat-suply network interaction compared to the single area CCHP model improved the clean energy utilization of the system, rationally allocates equipment capacity, promotes the local consumption of distributed energy, and provides better overall system benefits.

8 June 2021 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
MZMeixia Zhang
Meixia Zhang
QSQuanjie Sun
Quanjie Sun
YXYang Xiu
Yang Xiu
This study proposes a TOPSIS‐based method for assessing the ability of distribution networks to accept electric vehicles. This method establishes an assessment index system in terms of the rationality, safety, and economy of the distribution network operation, and assesses the capacity of the distribution network in all aspects. Firstly, a fuzzy theory‐based model of users' charging psychology under the influence of time‐of‐use electricity price was constructed, and the spatio‐temporal distribution of EV charging loads in the target area was predicted using travel chain theory and Monte Carlo methods. Secondly, considering the rationality, safety and economy of the distribution network operation, a comprehensive evaluation index system for acceptability has been constructed. Then, a comprehensive weighting method for evaluation indexes based on AHP and entropy weight method is proposed, and the improved TOPSIS is used to evaluate the acceptance capacity of the distribution network when EV charging loads are connected in different ways. Finally, a typical IEEE33 distribution network is used to simulate the time and space distribution of the charging load, and taking the charging load access schemes proposed in this paper to verify the effectiveness of the evaluation method.

1 October 2014 in Journal of International Council on Electrical Engineering
Verified
Journal Article
Open access
YXYang Xiu
Yang Xiu
LCLi Cheng
Li Cheng
LCLiu Chunyan
Liu Chunyan
– Hybrid super-capacitor and battery energy storage combine the advantages of power-type energy storage element and energy storage components, to avoid the disadvantages of a single energy storage technology, which is one of the important development direction of the energy storage technology. For energy storage applying in high-power, high-capacity and strong volatility applications, the article analyzes the composition of the total cost of the objective function in the hybrid super-capacitor and battery energy storage system entire life cycle, with regard to two decision variables - the number of each energy storage element batch and the batch of energy storage element in the objective function, proposing calculation method of energy storage component number and batch based respectively on Ragone plots and the equivalent cycle life. The example proves the effectiveness of the proposed method.

29 November 2018 in Frontiers in Energy
Verified
Journal Article
Closed access
PDF file
ZLZi Ling
Zi Ling
YXYang Xiu
Yang Xiu
ZLZilin Li
Zilin Li

19 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
CZChao Zheng
Chao Zheng
YXYang Xiu
Yang Xiu
CZChen Zhao
Chen Zhao
The large-scale grid integration of photovoltaic systems, accompanied by extensive power electronic equipment, exacerbates the risk of sub-synchronous oscillation (SSO) and poses a serious threat to the safe and stable operation of modern power systems. To address the limitation that traditional additional damping controllers rely on accurate mathematical models of the system, this paper applies model-free adaptive control (MFAC) to suppress sub-synchronous oscillation in photovoltaic systems. The proposed method requires no prior identification of the plant model and achieves adaptive control by online estimation of pseudo-partial derivatives using only system input-output data, with parameters optimized by particle swarm optimization. Simulation results show that the proposed controller can effectively shorten the settling time and suppress oscillations However, for oscillations induced by different mechanisms, it still has the limitation of requiring parameter re-optimization. This approach provides a new model-free technical pathway for sub-synchronous oscillation mitigation in grid-connected photovoltaic systems.

9 May 2026 in Energies
Verified
Journal Article
Open access
PDF file
LLLihaoyu Li
Lihaoyu Li
YXYang Xiu
Yang Xiu
Natural disasters and extreme meteorological events are primary causes of unplanned outages in modern power systems. Existing early warning methods suffer from insufficient non-linear feature extraction, severe class imbalance, and limited minority-class recall under single-classifier architectures. This paper proposes a seven-class meteorological fault early warning framework that integrates a sparse autoencoder (SAE), a G1–entropy composite weighting scheme, SMOTE oversampling, and a soft-voting BP–XGBoost ensemble. A leakage-free experimental protocol confines SMOTE exclusively to the training partition, eliminating data contamination from evaluation. Validated on 1955 fault records from a regional grid in East China covering 110 kV, 220 kV, and 500 kV voltage levels (2013–2022), the proposed framework achieved 96.42% accuracy and a 97.46% macro F1-score on the held-out test set, outperforming SVM (72.68%), Random Forest (89.31%), LSTM (81.47%), 1D-CNN (85.38%), and LightGBM (92.15%). Ablation experiments confirmed that SMOTE and G1–entropy weighting contributed macro F1 gains of 8.34 and 6.91 percentage points, respectively, while removing the XGBoost branch degraded accuracy by 28.25%. Temporal validation on 2019–2022 records yielded 91.57% accuracy, confirming temporal generalization. Error analysis further revealed that bidirectional misclassification between lightning damage and wind damage, rooted in shared atmospheric instability signatures, constitutes the dominant residual error source, providing theoretical guidance for future threshold optimization strategies.