José Mauro Teixeira Marinho

José Mauro Teixeira Marinho


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Closed access
VAVictor A. F. Almeida
Victor A. F. Almeida
GTGlauco N Taranto
Glauco N Taranto
JMJosé Mauro Teixeira Marinho
José Mauro Teixeira Marinho
This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square (RMS) phasor-domain, fundamental-frequency, three-phase, and dynamic simulation tools. The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation. The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements. This paper also presents and compares two strategies to limit reactive negative-sequence currents, and active and reactive positive-sequence currents. A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations.

11 February 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
GTGlauco N Taranto
Glauco N Taranto
TATatiana Assis
Tatiana Assis
JMJosé Mauro Teixeira Marinho
José Mauro Teixeira Marinho
This paper presents the modeling of some protective relays commonly used in generation and transmission systems, and their integration in three-phase RMS dynamic simulation tool. The three-phase models of the network and the power apparatuses, utilizing phase frame representation, enlarges the possibility to better represent the protection systems, since the relays involving ground and neutral circuitry can be modeled. The network can be modeled with a node-breaker topology representation, facilitating the integration of protecting relays and the switchgear. The relay modeling framework can also be used in positive-sequence RMS dynamic simulation tools with few adjustments in the measured quantities. Simulation results in realistic small and large-scale systems showing the performance of the proposed relay modeling framework and a comparison with an EMT tool are presented.

25 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
FPFrederico Oliveira Passos
Frederico Oliveira Passos
LMLúcio José Motta
Lúcio José Motta
GCGabriel Victor Dos Santos Corrêa Campos
Gabriel Victor Dos Santos Corrêa Campos
LVLucas Henrique Venâncio
Lucas Henrique Venâncio
IFIvan Paulo de Faria
Ivan Paulo de Faria
RRRodrigo M.P. Rosa
Rodrigo M.P. Rosa
The electrification of floating production, storage, and offloading (FPSO) units has emerged as a strategic solution to meet the growing demand for increased oil production while reducing carbon emissions associated with onboard gas turbine generation. Power-from-shore (PFS) systems represent a promising approach to achieving this goal, with transmission technologies based on high-voltage direct current (HVDC) and high-voltage alternating current (HVAC) solutions. Although HVDC is more suitable for long-distance and high-power applications, HVAC systems offer advantages in terms of robustness, simplicity, and operational maturity. Nevertheless, the reactive power compensation requirements arising from the high capacitance of submarine cables remain a major technical challenge. This study investigates and compares several reactive power compensation topologies applied to three distinct PFS systems. The proposed methodology enables a comprehensive evaluation of both onshore and subsea reactor placement strategies under technically and technologically feasible conditions. The results demonstrate that long-distance transmission of 75 MW over 250 km was achieved exclusively through subsea compensation configurations, which maintained efficiencies above 90% and voltage and current profiles within operational limits. Conversely, onshore-only compensation proved to be the most efficient solution for shorter transmission distances. The results demonstrate that the full electrification of an FPSO is technically feasible, with voltage and current profiles remaining within acceptable operational limits. The findings also indicate that mid-cable reactor placement (at 50%) is not the most effective configuration, with superior results observed for placements at 20–80% and 40–70% of the cable length. Overall, the outcomes confirm that subsea reactor placement enables higher power transfer over longer distances, significantly extending the technical boundaries traditionally separating HVDC and HVAC solutions. These results emphasize the need for continued technological development to make subsea shunt reactor installation a viable and reliable option for future FPSO electrification projects.

15 July 2025 in Energies
Verified
Journal Article
Open access
PDF file
ARAlex Reis
Alex Reis
JOJosé Carlos De Oliveira
José Carlos De Oliveira
CGCarlos Alberto Villegas Guerrero
Carlos Alberto Villegas Guerrero
JOJohnny José Orozco
Johnny José Orozco
LMLúcio José Motta
Lúcio José Motta
JMJosé Mauro Teixeira Marinho
José Mauro Teixeira Marinho
Driven by the environmental benefits associated with reduced greenhouse gas emissions, oil companies have intensified research efforts into reassessing the strategies used to meet the electrical demands of offshore production platforms. Among the various alternatives available, the deployment of onshore–offshore interconnections via High-Voltage Direct Current (HVDC) transmission systems has emerged as a promising solution, offering both economic and operational advantages. In addition to reliably meeting the electrical demand of offshore facilities, this approach enables enhanced operational flexibility due to the advanced control and regulation capabilities inherent to HVDC converter stations. Based on the use of interconnection through an HVDC link, aiming to evaluate the operation of the electrical system as a whole, this study focuses on evaluating dynamic events using the PSCAD software version 5.0.2 to analyze the direct online starting of a large induction motor and the sudden loss of a local synchronous generating unit. The simulation results are then analyzed to assess the effectiveness of both Grid-Following (GFL) and Grid-Forming (GFM) control strategies for the converters, while the synchronous generators are evaluated under both voltage regulation and constant power factor control operation, with a particular focus on system stability and restoration of normal operating conditions in the sequence of events.

9 July 2025 in Energies
Verified
Journal Article
Open access
PDF file
JOJohnny José Orozco
Johnny José Orozco
CGCarlos Alberto Villegas Guerrero
Carlos Alberto Villegas Guerrero
LMLúcio José Motta
Lúcio José Motta
MJMarcos R. de Paula Júnior
Marcos R. de Paula Júnior
JFJosé Maria Filho
José Maria Filho
CCCarlos Andre Carreiro Cavaliere
Carlos Andre Carreiro Cavaliere
In an effort to restrict further increases in climate change, governments and companies are exploring ways to reduce greenhouse gas (GHG) emissions. In this context, the oil industry, which contributes to indirect GHG emissions, is seeking ways to develop solutions to this issue. One such approach focuses on the connection of offshore oil production platforms to the onshore power grid via high-voltage direct current (HVDC), enabling a total or partial reduction in the number of local generators, which are generally powered by gas turbines. Therefore, this work aims to determine the technical feasibility, based on transient and dynamic stability analyses, of electrifying a system composed of six floating production storage and offloading (FPSO) units connected to a hub, which is powered by the onshore grid through submarine cables using HVDC technology. The analysis includes significant contingencies that could lead the system to undesirable operating conditions, allowing for the identification of appropriate remedial control actions. The analysis, based on real data and parameters, was carried out using PSCAD software. The results show that the modeled system is technically viable and could be adopted by oil companies. In addition to aligning with global warming mitigation goals, the proposal includes a complex system modeling approach, with the aim of enabling further study.