Dinesh Gundapaneni

Dinesh Gundapaneni

Biomedical Engineering, Wright State University, Dayton, Kentucky, USA
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2014 in Journal of Applied Biomaterials & Functional Materials
Verified
Journal Article
Closed access
DGDinesh Gundapaneni
Dinesh Gundapaneni
TGTarun Goswami
Tarun Goswami
Background: Polymethylmethacrylate (PMMA), also known as bone cement, is a commonly used adhesive material to fix implants in Total Hip Arthroplasty (THA). During implantation, bone cement undergoes a polymerization reaction which is an exothermic reaction and results in the release of heat to the surrounding bone tissue, which ultimately leads to thermal necrosis. Necrosis in the bony tissue results in early loosening of the implant, which causes pain and reduces the life of the implant. Purpose: The main objective of the present study was to understand the thermal isotherms in PMMA and to determine the optimal cement mantle thickness to prevent cell necrosis during THA. Methods: In this study, the environment in the bony tissue during implantation was simulated by constructing 3D solid models to observe the temperature distribution in the bony tissue at different cement mantle thicknesses (1 mm, 3 mm and 5 mm), by applying the temperature conditions that exist during the surgery. Stems made with Co-Cr-Mo, 316L stainless steel and Ti6Al4V were used, which acted as heat sinks, and a thermal damage equation was used to measure the bone damage. FEA was conducted based on temperature conditions and thermal isotherms at different cement mantle thicknesses were obtained. Results: Thermal isotherms derived with respect to distance in the bony tissue from the center of the cement mantle, and cell necrosis was determined at different mantle thicknesses. Based on the deduced results, cement mantle thickness of 1-5 mm does not cause thermal damage in the bony tissue. Conclusion: Considering the long term stability of the implant, cement mantle thickness range from 3 mm-5 mm was found to be optimal in THA to prevent cell necrosis.

1 June 2014 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
BEBradley Jay Elliot
Bradley Jay Elliot
DGDinesh Gundapaneni
Dinesh Gundapaneni
Tarun GoswamiTarun Goswami
Tarun Goswami

1 April 2012 in Biomatter
Verified
Journal Article
Open access
EGElizabeth Gunn
Elizabeth Gunn
DGDinesh Gundapaneni
Dinesh Gundapaneni
Tarun GoswamiTarun Goswami
Tarun Goswami
Femoral loosening is one of the most prevalent causes of revision orthopedic surgeries. Cement mantle thickness has been directly correlated with femoral loosening. If the mantle is too thick, ther...

1 April 2015 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DGDinesh Gundapaneni
Dinesh Gundapaneni
JTJames T. Tsatalis
James T. Tsatalis
RLRichard T. Laughlin
Richard T. Laughlin
Tarun GoswamiTarun Goswami
Tarun Goswami

1 December 2016 in Engineering Failure Analysis
Verified
Journal Article
Closed access
DGDinesh Gundapaneni
Dinesh Gundapaneni
RLRichard T. Laughlin
Richard T. Laughlin
TGTarun Goswami
Tarun Goswami

1 January 2016 in Engineering Failure Analysis
Verified
Journal Article
Closed access
TGTarun Goswami
Tarun Goswami
DGDinesh Gundapaneni
Dinesh Gundapaneni
MSMatthew Slocum
Matthew Slocum
PPPuchwein Paul
Puchwein Paul
SCSommitsch Christof
Sommitsch Christof