Thorough quality control (QC) can be time consuming when working with large-scale medical imaging datasets, yet necessary, as poor-quality data can lead to erroneous conclusions or poorly trained machine learning models. Most efforts to reduce data QC time rely on quantitative outlier detection, which cannot capture every instance of algorithm failure. Thus, there is a need to visually inspect every output of data processing pipelines in a scalable manner. We design a QC pipeline that allows for low time cost and effort across a team setting for a large database of diffusion-weighted and structural magnetic resonance images. Our proposed method satisfies the following design criteria: 1.) a consistent way to perform and manage quality control across a team of researchers, 2.) quick visualization of preprocessed data that minimizes the effort and time spent on the QC process without compromising the condition/caliber of the QC, and 3.) a way to aggregate QC results across pipelines and datasets that can be easily shared. In addition to meeting these design criteria, we also provide a comparison experiment of our method to an automated QC method for a T1-weighted dataset of images and an inter-rater variability experiment for several processing pipelines. The experiments show mostly high agreement among raters and slight differences with the automated QC method. While researchers must spend time on robust visual QC of data, there are mechanisms by which the process can be streamlined and efficient.
The human brain relies on a complex network of connections to function, with white matter acting as the primary communication highway between different brain regions 1,2 . Disruptions in these critical communication pathways are linked to several neurological, psychiatric and developmental disorders 3,4 . Although clinicians have long used standard growth charts to track physical development 5 , with more recent work translating these to whole-brain and grey matter measurements 6–9 , there has been no equivalent reference standard for white matter. Establishing a readily available normative reference is an imperative first step if we hope to utilize these white matter structural biomarkers clinically. Here we present lifespan reference charts for human brain white matter. By processing and standardizing 35,120 brain scans from diverse global studies, we mapped the typical growth, maturation and age-related decline of specific brain pathways from birth to 100 years of age. These reference charts establish a fundamental benchmark for healthy brain development and ageing, allowing researchers and clinicians to quantify how an individual’s brain deviates from typical patterns and highlighting disorder-related alterations. Furthermore, the accompanying open access charts enable the scientific and clinical communities to evaluate new patient and research data against these normative baselines, facilitating future clinical and neuroscience studies.
Curating, processing, and combining large-scale medical imaging datasets from national studies is a non-trivial task due to the intense computation and data throughput required, variability of acquired data, and associated financial overhead. Existing platforms or tools for large-scale data curation, processing, and storage have difficulty achieving a viable cost-to-scale ratio of computation speed for research purposes, either being too slow or too expensive. Additionally, management and consistency of processing large data in a team-driven manner is a non-trivial task. We design a BIDS-compliant method for an efficient and robust data processing pipeline of large-scale diffusion-weighted and T1-weighted MRI data compatible with low-cost, high-efficiency computing systems. Our method accomplishes automated querying of data available for processing and process running in a consistent and reproducible manner that has long-term stability, while using heterogenous low-cost computational resources and storage systems for efficient processing and data transfer. We demonstrate how our organizational structure permits efficiency in a semi-automated data processing pipeline and show how our method is comparable in processing time to cloud-based computation while being almost 20 times more cost-effective. Our design allows for fast data throughput speeds and low latency to reduce the time for data transfer between storage servers and computation servers, achieving an average of 0.60 Gb/s compared to 0.33 Gb/s for using cloud-based processing methods. The design of our workflow engine permits quick process running while maintaining flexibility to adapt to newly acquired data.
Diffusion-weighted magnetic resonance imaging (dMRI) is a non-invasive imaging modality that provides insight into the white matter (WM) microstructure in the brain.1 In diffusion tensor imaging (DTI), the signal from a dMRI scan is modeled as tensors that describe the direction and degree of water diffusion at each voxel.2 One of the most common ways to study a DTI model is through scalar metrics. Two of the most common diffusion scalars are fractional anisotropy (FA), which describes the directedness of diffusion, and mean diffusivity (MD), which describes the average magnitude of diffusion. While DTI is limited in its ability to describe crossing axon fibers in the brain,2 it is still useful to study the changes in brain morphology due to disease or aging.3–5
19 September 2025 in Computers in Biology and Medicine
Defacing is often applied to head magnetic resonance image (MRI) datasets prior to public release to address privacy concerns. The alteration of facial and nearby voxels has provoked discussions about the true capability of these techniques to ensure privacy as well as their impact on downstream tasks. With advancements in deep generative models, the extent to which defacing can protect privacy is uncertain. Additionally, while the altered voxels are known to contain valuable anatomical information, their potential to support research beyond the anatomical regions directly affected by defacing remains uncertain. To evaluate these considerations, we develop a refacing pipeline that recovers faces in defaced head MRIs using cascaded diffusion probabilistic models (DPMs). The DPMs are trained on images from 180 subjects and tested on images from 484 unseen subjects, 469 of whom are from a different dataset. To assess whether the altered voxels in defacing contain universally useful information, we also predict computed tomography (CT)-derived skeletal muscle radiodensity from facial voxels in both defaced and original MRIs. The results show that DPMs can generate high-fidelity faces that resemble the original faces from defaced images, with surface distances to the original faces significantly smaller than those of a population average face (p < 0.05). This performance also generalizes well to previously unseen datasets. For skeletal muscle radiodensity predictions, using defaced images results in significantly weaker Spearman's rank correlation coefficients compared to using original images (p ≤ 10-4). For shin muscle, the correlation is statistically significant (p < 0.05) when using original images but not statistically significant (p > 0.05) when any defacing method is applied, suggesting that defacing might not only fail to protect privacy but also eliminate valuable information. We advocate two solutions for data sharing that comply with privacy: 1) share skull-stripped images along with measurements of facial and cranial features extracted before skull-stripping for public access, while acknowledging that this approach inherently compromises many research potentials; or 2) share the unaltered images with privacy enforced through policy restrictions.