Mohamed ALI MOUSSA

Prof. Mohamed ALI MOUSSA

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2022 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
MMMohamed ALI MOUSSA
Mohamed ALI MOUSSA
ADA. Derrouazin
A. Derrouazin
MLM. Latroch
M. Latroch
MAMichel Aillerie
Michel Aillerie
Introduction. This article proposes an improved energy management and optimization system with an intelligent economic strategy based on fuzzy logic technology with multiple inputs and outputs (I/O). It is used to control hybrid electric energy sources built around photovoltaic solar panels, wind turbine and electric energy storage system assisted by the electric grid. The novelty in this work that solar photovoltaic, wind turbine and storage system energy sources are prioritized over the grid network which is solicited only during adverse weather conditions, in order to supply a typical household using up to 4,000 Wh per day. In addition of that, the surplus of renewable energy produced during favorable climatic condition is used to produce hydrogen suitable for household heating and cooking using eletrolyzer system. Purpose. Development of improved energy management and optimization system with an intelligent economic strategy based on fuzzy logic technology. This system is embedded on Arduino 2560 mega microcontroller, on which the fundamental program of fuzzy logic and the distribution of events with all possible scenarios have been implemented according to a flowchart allowing the management of the hybrid system. Methods as well as a parametric search and a simulation to characterize the system, are carried out in order to put on the proposed techniques to ensure continuous accommodation at home. Results. The proposed system results confirm their effectiveness by visualizing the output control signals from the electronic switches. Practical value of which transmits power through a single-phase DC/AC converter to power the AC load for the accommodation.

23 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
AAAmari Abderrahmane
Amari Abderrahmane
MMMohamed ALI MOUSSA
Mohamed ALI MOUSSA
KSKherfane Samir
Kherfane Samir
MBMHAMDI Benalia
MHAMDI Benalia
TBTahar Benaissa
Tahar Benaissa
VKVladislav Kuchanskyy
Vladislav Kuchanskyy
Commutation failures (CFs), which occur when current transfer between valves in line-commutated converter high-voltage direct current (LCC-HVDC) systems is disrupted, pose a challenge in weak alternating current (AC) networks. This paper introduces a coordinated control strategy that combines a fuzzy self-tuning proportional-integral (PI) controller (FSTPIC) and a static synchronous compensator (STATCOM) device to mitigate CFs and enhance system stability. The approach applies the FSTPIC to both converters of the HVDC link, while the STATCOM at the inverter side delivers dynamic reactive power and voltage support during AC faults. We test this strategy on the CIGRE HVDC benchmark system using MATLAB/SIMULINK simulations. The results demonstrate that the proposed method significantly reduces CFs, mitigates transient oscillations, and shortens recovery time compared to conventional control techniques. This coordinated control boosts voltage stability and the system’s ability to ride through faults, confirming its superiority under various fault scenarios in weak-grid conditions.

2 July 2025 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
MSM. L’hAdj Said
M. L’hAdj Said
MMMohamed ALI MOUSSA
Mohamed ALI MOUSSA
TBT. Bessaad
T. Bessaad
Introduction. Nowadays, many researches are being done on wind turbines providing electrical energy to a stable power grid by via a doubly fed induction generator (DFIG), but the studies on the autonomous networks are rare, due the difficulty of controlling powers often close to the nominal power of the generator. Goal. This paper presents a variable speed constant frequency (VSCF) autonomous control system to supply isolated loads (linear or non-linear). The main objective is the design of an effective strategy to reduce harmonic currents induced via the non-linear loads such as rectifier bridge with 6 diodes. The novelty of the work consists in study of system composed of a DFIG providing energy by his stator to a stand-alone grid. It uses a static converter connected to the rotor allowing operation in hypo and hyper synchronism. A permanent magnet synchronous machine (PMSM) connected to a wind turbine supplies this converter, that is sized proportionately to the variation range of the necessary rotational speed. In the case of linear loads there is no problem, all desired parameters are well controlled but in the non-linear loads case such as rectifier bridge with 6 diodes there is the harmonic problem. For this purpose, to reduce this harmonic, the proposed solution is the installation of a LC filter. Methods. The DFIG is controlled to provide a constant voltage in amplitude and frequency independently of the grid load or the drive turbine speed. This command is vector control in a reference related to the stator field. The stator flux is aligned along the d axis of this landmark allowing thus the decoupling of the active and reactive stator powers of DFIG. The DFIG is controlled by an internal control loop of rotor flux and an external control loop of output stator voltage. We present also the control of the PMSM and the DC bus of the converter. The PMSM is controlled by an internal control loop of the current and an external control loop of the continuous bus of the converter according to its nominal value. The control system of wind generator based on the maximum power point tracking and the control of bus continuous at output rectifier knowing that the non-linear loads introduce high harmonic currents and disrupt the proper functioning of the system. The installation of a LC filter between the stator and the network to be supplied reduce harmonics. Results. Simulation results carried out on MATLAB/Simulink show that this filter allows obtaining a quasi-sinusoidal network voltage and it also has the advantage of a simple structure, a good efficiency and a great performance. This proves the feasibility and efficiency of the proposed system for different loads (linear or non-linear). Practical value. This proposed system is very performing and useful compared to others because it ensures the permanent production of electricity at VSCF to feed isolated sites, whatever the load supplied (linear or non-linear), without polluting the environment so that the use of wind energy is very important to reduce the greenhouse effect. References 34, figures 9.

8 March 2026 in REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
Verified
Journal Article
Open access
PDF file
MBMokhtari Bachir
Mokhtari Bachir
MMMohamed ALI MOUSSA
Mohamed ALI MOUSSA
This paper proposes neural switching tables (NCST, NRST) to improve direct torque control (DTC) of a permanent magnet synchronous motor (PMSM) driven by a four-level multicellular inverter (4LMI). Classical DTC suffers from high torque and flux ripples, which can cause mechanical stress and reduce reliability. The neural approach replaces conventional and reduced lookup tables with compact neural network models, allowing seamless integration in Simulink without large precomputed datasets. Simulation results confirm identical control behavior to that in classical tables, while reducing torque ripple by approximately 50% and maintaining flux within hysteresis limits. This solution enhances modularity, simplicity, and scalability, making it a promising step toward AI-based DTC strategies.

1 December 2023 in Intellectual Journal of Energy Harvesting and Storage
Verified
Journal Article
Open access
PDF file
MMMohamed ALI MOUSSA
Mohamed ALI MOUSSA
ADAhmed Derouazin
Ahmed Derouazin
MLMaamar Latroch
Maamar Latroch
MAMichel Aillerie
Michel Aillerie
This work proposes to a novel economic smart strategy energy flow management system based on multiples inputs and outputs fuzzy logic technic applied for hybrid photovoltaic solar panels with wind turbine and storage system, assisted by the electric grid. A priority order is given to the renewable and storage energy sources allowing a non- interrupted energy supply for typical dwelling consuming up to 4,000 Wh per day. This system is governed by an Arduino 2560 mega microcontroller where has been implemented the core fuzzy logic program with event display. A sizing of the hybrid system and parametric study of the system and simulation are performed in order to highlight the proposed control strategy to finally guarantee a continuous home accommodation. The preliminary results concern the electronic switches output control signals, which convey the energy via single-phase DC/AC inverter to power the alternative current load for accommodation.

1 December 2024 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
ADAhmed Derrouazin
Ahmed Derrouazin
MMMohamed ALI MOUSSA
Mohamed ALI MOUSSA
MBMokhtari Bachir
Mokhtari Bachir
Due to the increasing use of power electronics equipment, the quality of energy in the electrical network is deteriorating sharply. Indeed, this equipment consumes non-sinusoidal currents, even if they are powered by a sinusoidal voltage, and behaves like generators of harmonic currents. To "clean up" the network, there are several means, among them; the parallel active filter (PAF) which is the most used means because it has proven its effectiveness for the elimination of harmonics caused by a non-linear load. However, this PAF must prove its effectiveness constantly, because the unexpected variation of the loads supplied by the electrical network can call into question its effectiveness. The main objective of this work is to confirming that PAF is a permanent filter and adapts automatically and instantaneously to any load. For this, several simulation tests were carried out under MATLAB/Simulink. The results obtained are very satisfactory, as they confirmed the robustness and self-adaptability of the filter with respect to the sudden variation in loads, the tests carried out on the PAF also show us that the response of the filter is done almost in real time.