Yongsheng Hao

Dr. Yongsheng Hao


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2024 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
ZCZhuo Chen
Zhuo Chen
YHYongsheng Hao
Yongsheng Hao
ZSZhi-gang Su
Zhi-gang Su
GZGang Zhao
Gang Zhao
Kwang Y. LeeKwang Y. Lee
Kwang Y. Lee
Flue gas desulfurization in thermal power plants is critical to the environmental and human health. Aiming for field application, this article presents a new predictor-and-observer-based active disturbance rejection control (ADRC) scheme for Wet Flue Gas Desulfurization (WFGD) process which is subject to long time delay and unknown disturbances. First, the working principles and control problems of WFGD system are illustrated, and the WFGD process model is identified based on the field experimental data. Then, a predictor-based ADRC approach is carefully devised to address its control issues. Specifically, a filtered smith predictor (FSP) is designed to obtain stable delay-free prediction output, and a reduced-order model-assisted extended state observer (MESO) is devised to estimate the “total disturbance” with less phase lag. Based on the equivalent control structure, its stability, including the perfect delay matching and delay mismatch cases, is theoretically investigated using the zero exclusion criterion. A simple “separation tuning procedure” is also provided, where the ADRC parameters are tuned directly based on the delay-free process, while the FSP filter is specified to achieve desired robustness. Finally, the validity of the proposed method is demonstrated by comparison simulations and field tests in a 1000MW thermal power unit. Note to Practitioners —This article focuses on sulfur dioxide (SO $_2$ ) control and proposes a new predictor-based ADRC approach for the WFGD process subject to long time delay and unknown disturbances. Taking the WFGD system as an example, it systematically describes the whole process of modeling, control system design and simulation & experimental verification, which can provide an intuitive reference for practitioners. The zero exclusion criterion is used to analyze the closed-loop stability and determine the stable delay range for a given predictor-based ADRC control system. A detailed tuning procedure is also provided, which can simplify the time-consuming tuning process and help engineers grasp the performance and robustness of the control system. It is evident that the proposed method can be extended to a general class of industrial time-delay systems, which facilitates the practitioner’s practice in general single-input-single-output time-delay system control. The field test results demonstrate the superiority of the proposed method and show promise for practical application in other systems.

1 September 2022 in ISA Transactions
Verified
Journal Article
Closed access
ZCZhuo Chen
Zhuo Chen
YHYongsheng Hao
Yongsheng Hao
ZSZhi-gang Su
Zhi-gang Su
LSLi Sun
Li Sun

6 October 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
YHYongsheng Hao
Yongsheng Hao
ZCZhuo Chen
Zhuo Chen
LSLi Sun
Li Sun
JLJunyu Liang
Junyu Liang
HZHongxia Zhu
Hongxia Zhu
Superheated steam temperature (SST) is one of the most critical parameters for the process safety, overall efficiency and pollution reduction of coal-fired power plants. However, SST control is challenging due to various disturbances and model uncertainties, especially in the face of the growing penetration of intermittent renewable energy into the power grid. To this end, a cascaded Disturbance Observer-PI (DOB-PI) control strategy is proposed to enhance control performance. The observer design and parameter tuning are carried out through mechanism analysis on the proposed structure. Furthermore, a robust loop shaping method is introduced as a hard constraint to balance the control performance and robustness. The controller parameters are optimized based on the multi-objective artificial bee colony optimization (MOABC) algorithm. Simulation results show that the proposed cascaded DOB-PI control strategy can significantly improve the disturbance rejection performance of both the inner- and outer-loops of the SST control system. This paper indicates promising prospects for the proposed method in future applications.

11 November 2022 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
KXKai Xuan
Kai Xuan
YHYongsheng Hao
Yongsheng Hao
ZLZhouyuan Liang
Zhouyuan Liang
JZJunli Zhang
Junli Zhang
Comprehensive performance evaluation is a fundamental part of the design and operation optimization of distributed integrated energy systems (IES), and the evaluation is currently focused on three types of elements: economic, energy efficiency and environmental protection. In this paper, energy use quality elements are proposed from the high energy supply requirements of users for distributed IES and characterized by the supply-demand imbalance rate indicator. Then the Analytic Hierarchy Process (AHP) and the information entropy method are combined to form a combined evaluation method by weighing the subjective and objective methods. The comprehensive performance evaluation of distributed IES with nine indicators considering four elements of economy, energy efficiency, environmental protection and energy use quality is realized. The feasibility and validity of the proposed indicators and the difference between the proposed combination method and the existing combination method are verified by the calculation examples. In the single-objective optimization with optimal energy use quality, the supply-demand imbalance rates for heat and cold are −0.05 and −0.035, respectively, which are the best among the five optimization schemes and fully guarantee the stability and quality of energy supply. However, its CO2 emission of 5738.91 (t/year) shows that this indicator is not suitable for the limitation of single-objective optimization, and it would be more suitable for comprehensive optimization with the above three indicators. The weights of operation cost, heat and cold supply-demand imbalance in the AHP method are 0.2247,0.0539,0.0539. The corresponding weights in the information entropy method are 0.0930,0.1670,0.1864. The corrected values are 0.1999, 0.0861, 0.0961. The results show the corrective effect of the information entropy method on the AHP. In addition, the combination method proposed in this paper corrects the configuration cost term to 0.2032, which is larger than both 0.1588 in the AHP method and 0.1388 in the information entropy method, highlighting the difference from existing combination methods. The above data show that the comprehensive evaluation by the AHP-information entropy method can effectively consider the four elements’ role. It provides a new idea for the research on the impact of distributed IES energy storage on the energy use quality of the system and the construction and operation optimization of the comprehensive performance evaluation indicator of the system.

21 February 2025 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
ZCZhuo Chen
Zhuo Chen
YHYongsheng Hao
Yongsheng Hao
ZSZhi-gang Su
Zhi-gang Su
LSLi Sun
Li Sun
Cascade control permeates a wide range of industrial processes, due to its significant improvement in disturbance rejection. However, conventional cascade control turns laborious to control the sluggish outer loop and suffers from complex inner-outer-loop coupling dynamics. Combining the merits of conventional cascade control and powerful capability of disturbance observer (DOB), this paper presents a cascade disturbance observer (CDOB) based control approach for cascaded systems. The resulting cascade control system features equivalent decoupling of the inner- and outer-loop disturbance rejection (DR), which allows the relevant filters to be designed separately. For the inner-loop filter, a robust design approach, directly based on the performance specifications and robustness constraints, is proposed, which enables an intuitive trade-off between performance and robustness. A novel filter is devised to improve the sluggish outer-loop DR performance. With the feedforward controller designed based on the nominal model, a composite control strategy is finally constructed. Some simulations and experiments are presented to validate the efficacy of the proposed method, and the significant performance improvements depict application prospects in process control.