Osher Osher

Dr. Osher Osher


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2008 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
OOOsher Osher
Osher Osher
To study the incidence, course, and common factors of patients with negative dysphotopsia and consider the possible role of the corneal incision in cases in which symptoms are transient. Private practice and the University of Cincinnati, College of Medicine, Cincinnati, Ohio, USA. Phacoemulsification with implantation of a single-piece acrylic intraocular lens (IOL) was performed in 250 consecutive routine cataract procedures. Patients were asked whether they noticed a temporal shadow on the day after surgery and were followed by serial evaluations for 3 years. Evaluations included subjective questionnaires and objective testing. The incidence of negative dysphotopsia was 15.2% on the first postoperative day, decreasing to 3.2% after 1 year, then 2.4% after 2 and 3 years. Common findings included a shallow orbit, prominent globe, space greater than 0.45 mm between the iris and IOL by ultrasound biomicroscopy, and perimetric comet-shaped light in the area corresponding to the shadow. Slitlamp revealed a transparent peripheral capsule and a shadow sign in which a linear shadow on the iris became curvilinear as the light from the slit beam was projected through the incision toward the pupil. Two groups of patients experienced negative dysphotopsia that rapidly resolved or remained unchanged from the first postoperative day. It is hypothesized that the corneal edema associated with a beveled temporal incision contributes to transient negative dysphotopsia.

1 June 2005 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
OOOsher Osher
Osher Osher
MSMichael E. Snyder
Michael E. Snyder
RCRobert J. Cionni
Robert J. Cionni
A new modification of the Siepser sliding knot technique allows the surgeon to create a locking knot when performing iris reconstruction or intraocular lens fixation to the iris.

1 March 2007 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
OOOsher Osher
Osher Osher
To determine whether microcoaxial phacoemulsification can be reliably and safely performed in a clinical setting and whether a full-sized single-piece acrylic intraocular lens (IOL) can be implanted through a 2.2 mm incision. Private practice, Cincinnati, Ohio, USA. One hundred consecutive patients had cataract surgery by microcoaxial phacoemulsification with the MicroSmooth Ultrasleeve (Alcon Surgical) through a 2.2 mm incision. Anterior chamber stability, incision competency, safety of IOL implantation, intraoperative complications, efficiency, and the learning curve were evaluated. Uncorrected visual acuity (UCVA) on the first postoperative day, corneal appearance, intraocular pressure, and postoperative complications were also analyzed. Anterior chamber stability and incision competency were consistently excellent. The incision enlarged from 2.2 mm to 2.3 mm in 80% of the patients, to 2.4 mm in 12%, and to 2.5 mm in 8%. A high-power IOL and/or IOL insertion difficulty may account for 7 of the latter 8 cases. Efficiency and safety were equivalent to those in traditional phacoemulsification. The learning curve with the Ultrasleeve was minimal, although IOL implantation was initially more difficult. The UCVA on the first postoperative day was 20/40 or better in 91% of patients, a result consistent with mild corneal edema. There were no postoperative complications. The clinical results in a prospective series of 100 patients confirmed the efficacy and safety of microcoaxial phacoemulsification. Fluidic advantages, competent incisions, and the new countertraction implantation technique provide another approach to achieving less-invasive, high-quality cataract surgery.

1 March 2007 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
OOOsher Osher
Osher Osher
VIValentine P. Injev
Valentine P. Injev
To examine and compare the fluidic, thermal, and incision behaviors of 2.2 mm microcoaxial and sleeveless bimanual phacoemulsification. Private practice, Cincinnati, Ohio, USA. Fluidic performance of microcoaxial phacoemulsification and sleeveless bimanual microphacoemulsification was examined using a reduced-size irrigating sleeve and numerous irrigating choppers, respectively. Incision temperature during phacoemulsification, incision sealability after phacoemulsification, and incision leak were compared in cadaver eyes. Porcine eyes were used to determine whether a full-sized single-piece SN60AT intraocular lens (IOL) (AcrySof) could be inserted through a 2.2 mm incision. Fluidic comparison indicated greater irrigation flow and a more stable occlusion break response with the microcoaxial setup than with the sleeveless bimanual setup under the same test conditions. Incision temperature during phacoemulsification, incision sealability after phacoemulsification, and incision leakage tests indicated that the microcoaxial setup produced less temperature rise, better incision sealability, and less incision leakage. A full-sized SN60AT IOL could be inserted through a 2.2 mm incision. Laboratory results indicate that microcoaxial phacoemulsification through a 2.2 mm incision offers fluidic-, thermal-, and incision-related benefits over sleeveless bimanual microphacoemulsification. Moreover, a full-sized single-piece acrylic IOL could be safely implanted without enlarging the 2.2 mm incision.

1 January 2014 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
ABAndrew W. Browne
Andrew W. Browne
OOOsher Osher
Osher Osher
PURPOSE: To increase precision in toric intraocular lens selection by reducing the frequency of outliers that arise from technology-dependent variability during the preoperative assessment for routine cataract surgery. METHODS: Mean preoperative values for absolute sphere, amount of astigmatism, and steepest cylindrical axis were obtained for 87 eyes (54 patients) each with a manual keratometer and four automated keratometers. The mean sphere, amount of astigmatism, and steepest cylindrical axis across five technologies for each eye were defined as the meld sphere, meld astigmatism, and meld axis, respectively. Each technology was evaluated against the meld by Bland–Altman analysis, Student’s paired t test, and correlation coefficients. Further comparison between individual technologies and the meld quantified the number of outlier measurements each technology produced. RESULTS: The number of outliers between individual keratometers and the meld differed with specific measurement of sphere, axis, or amount of astigmatism. Although statistical analysis using Bland–Altman plots, correlation coefficients, and paired t tests suggested insignificant difference from meld measurements for each parameter, precision-guided analysis presented more clinically significant outliers. The number of outliers can be reduced for sphere (range: 2%–46% to 1%–6%), astigmatism (range: 6%–23% to 0%–2%), and axis outliers (range: 15%–27% to 3%–6%) by averaging measurements from automated and manual keratometers. CONCLUSIONS: Although multiple keratometry technologies produced similar, average measurements, the authors found a disturbing number of outliers that may be overlooked when employing a single technology. Measurement errors can be dramatically reduced by averaging measurements from manual keratometry with any automated technology to make toric lens selection more precise. [ J Refract Surg. 2014;30(1):67–72.]

1 August 2012 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
OOOsher Osher
Osher Osher
KGKarl C. Golnik
Karl C. Golnik
GBGraham Barrett
Graham Barrett
KSKimiya Shimizu
Kimiya Shimizu
To determine whether extreme pseudophakic monovision can reduce or eliminate diplopia in patients with cataract and longstanding acquired strabismus. Department of Ophthalmology, University of Cincinnati, and the Cincinnati Eye Institute, Cincinnati, Ohio, USA. Case series. Intentional extreme monovision was created in patients with stable diplopia having cataract surgery. Intraocular lens selection was targeted for emmetropia in 1 eye and at least 3.0 diopters of myopia in the fellow eye. Twelve patients with stable diplopia attained excellent uncorrected distance and near vision with a marked reduction in or elimination of double vision. Patients with stable acquired strabismus with diplopia may be candidates for extreme pseudophakic monovision, which may be a new strategy to eliminate double vision. No author has a financial or proprietary interest in any material or method mentioned.