Marc Lilot

Prof. Dr. Marc Lilot

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2019 in Critical Care
Verified
Journal Article
Open access
PDF file
MJMatthias Jacquet-Lagrèze
Matthias Jacquet-Lagrèze
NBNourredine Bouhamri
Nourredine Bouhamri
PPPhilippe Portran
Philippe Portran
RSRémi Schweizer
Rémi Schweizer
FBFlorent Baudin
Florent Baudin
JFJean Luc Fellahi
Jean Luc Fellahi
A peripheral perfusion-targeted resuscitation during early septic shock has shown encouraging results. Capillary refill time, which has a prognostic value, was used. Adding accuracy and predictability on capillary refill time (CRT) measurement, if feasible, would benefit to peripheral perfusion-targeted resuscitation. We assessed whether a reduction of capillary refill time during passive leg raising (ΔCRT-PLR) predicted volume-induced peripheral perfusion improvement defined as a significant decrease of capillary refill time following volume expansion. Thirty-four patients with acute circulatory failure were selected. Haemodynamic variables, metabolic variables (PCO2gap), and four capillary refill time measurements were recorded before and during a passive leg raising test and after a 500-mL volume expansion over 20 min. Receiver operating characteristic curves were built, and areas under the curves were calculated (ROCAUC). Confidence intervals (CI) were performed using a bootstrap analysis. We recorded mortality at day 90. The least significant change in the capillary refill time was 25% [95% CI, 18–30]. We defined CRT responders as patients showing a reduction of at least 25% of capillary refill time after volume expansion. A decrease of 27% in ΔCRT-PLR predicted peripheral perfusion improvement with a sensitivity of 87% [95% CI, 73–100] and a specificity of 100% [95% CI, 74–100]. The ROCAUC of ΔCRT-PLR was 0.94 [95% CI, 0.87–1.0]. The ROCAUC of baseline capillary refill time was 0.73 [95% CI, 0.54–0.90] and of baseline PCO2gap was 0.79 [0.61–0.93]. Capillary refill time was significantly longer in non-survivors than in survivors at day 90. ΔCRT-PLR predicted peripheral perfusion response following volume expansion. This simple low-cost and non-invasive diagnostic method could be used in peripheral perfusion-targeted resuscitation protocols. CPP Lyon Sud-Est II ANSM: 2014-A01034-43 Clinicaltrial.gov, NCT02248025 , registered 13th of September 2014

19 March 2015 in Critical Care
Verified
Journal Article
Open access
PDF file
JRJoseph Rinehart
Joseph Rinehart
MLMarc Lilot
Marc Lilot
CLChristine Lee
Christine Lee
Alexandre JoostenAlexandre Joosten
Alexandre Joosten
THTrish Huynh
Trish Huynh
MCMaxime Cannesson
Maxime Cannesson
Introduction: Goal-directed fluid therapy strategies have been shown to benefit moderate- to high-risk surgery patients. Despite this, these strategies are often not implemented. The aim of this study was to assess a closed-loop fluid administration system in a surgical cohort and compare the results with those for matched patients who received manual management. Our hypothesis was that the patients receiving closed-loop assistance would spend more time in a preload-independent state, defined as percentage of case time with stroke volume variation less than or equal to 12%.Methods: Patients eligible for the study were all those over 18 years of age scheduled for hepatobiliary, pancreatic or splenic surgery and expected to receive intravascular arterial blood pressure monitoring as part of their anesthetic care. The closed-loop resuscitation target was selected by the primary anesthesia team, and the system was responsible for implementation of goal-directed fluid therapy during surgery. Following completion of enrollment, each study patient was matched to a non–closed-loop assisted case performed during the same time period using a propensity match to reduce bias.Results: A total of 40 patients were enrolled, 5 were ultimately excluded and 25 matched pairs were selected from among the remaining 35 patients within the predefined caliper distance. There was no significant difference in fluid administration between groups. The closed-loop group spent a significantly higher portion of case time in a preload-independent state (95 ± 6% of case time versus 87 ± 14%,P=0.008). There was no difference in case mean or final stroke volume index (45 ± 10 versus 43 ± 9 and 45 ± 11 versus 42 ± 11, respectively) or mean arterial pressure (79 ± 8 versus 83 ± 9). Case end heart rate was significantly lower in the closed-loop assisted group (77 ± 10 versus 88 ± 13,P=0.003).Conclusion: In this case–control study with propensity matching, clinician use of closed-loop assistance resulted in a greater portion of case time spent in a preload-independent state throughout surgery compared with manual delivery of goal-directed fluid therapy.Trial registration: ClinicalTrials.gov Identifier:NCT02020863. Registered 19 December 2013

1 May 2021 in Behaviour Research and Therapy
Verified
Journal Article
Closed access
SSSophie Schlatter
Sophie Schlatter
LSLaura Schmidt
Laura Schmidt
MLMarc Lilot
Marc Lilot
AGAymeric Guillot
Aymeric Guillot
UDUrsula Debarnot
Ursula Debarnot

16 April 2020 in Anesthesiology
Verified
Journal Article
Closed access
PDF file
FSFlorent Sigwalt
Florent Sigwalt
GPGuillaume Petit
Guillaume Petit
JEJean-Noel Evain
Jean-Noel Evain
DCDamien Claverie
Damien Claverie
MBMonique Bui
Monique Bui
MLMarc Lilot
Marc Lilot
Background: High-fidelity simulation improves participant learning through immersive participation in a stressful situation. Stress management training might help participants to improve performance. The hypothesis of this work was that Tactics to Optimize the Potential, a stress management program, could improve resident performance during simulation. Methods: Residents participating in high-fidelity simulation were randomized into two parallel arms (Tactics to Optimize the Potential or control) and actively participated in one scenario. Only residents from the Tactics to Optimize the Potential group received specific training a few weeks before simulation and a 5-min reactivation just before beginning the scenario. The primary endpoint was the overall performance during simulation measured as a composite score (from 0 to 100) combining a specific clinical score with two nontechnical scores (the Ottawa Global Rating Scale and the Team Emergency Assessment Measure scores) rated for each resident by four blinded independent investigators. Secondary endpoints included stress level, as assessed by the Visual Analogue Scale during simulation. Results: Of the 134 residents randomized, 128 were included in the analysis. The overall performance (mean ± SD) was higher in the Tactics to Optimize the Potential group (59 ± 10) as compared with controls ([54 ± 10], difference, 5 [95% CI, 1 to 9]; P = 0.010; effect size, 0.50 [95% CI, 0.16 to 0.91]). After specific preparation, the median Visual Analogue Scale was 17% lower in the Tactics to Optimize the Potential group (52 [42 to 64]) than in the control group (63 [50 to 73]; difference, −10 [95% CI, −16 to −3]; P = 0.005; effect size, 0.44 [95% CI, 0.26 to 0.59]. Conclusions: Residents coping with simulated critical situations who have been trained with Tactics to Optimize the Potential showed better overall performance and a decrease in stress level during high-fidelity simulation. The benefits of this stress management training may be explored in actual clinical settings, where a 5-min Tactics to Optimize the Potential reactivation is feasible prior to delivering a specific intervention. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:

1 December 2016 in Anaesthesia Critical Care & Pain Medicine
Verified
Journal Article
Closed access
CBChristian Bauer
Christian Bauer
TRThomas Rimmelé
Thomas Rimmelé
ADAntoine Duclos
Antoine Duclos
NPNathalie Prieto
Nathalie Prieto
JCJean-Christophe Cejka
Jean-Christophe Cejka
JLJean-Jacques Lehot
Jean-Jacques Lehot

1 January 2016 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
MJMatthias Jacquet-Lagrèze
Matthias Jacquet-Lagrèze
FBFlorent Baudin
Florent Baudin
JDJean Stéphane David
Jean Stéphane David
JFJean Luc Fellahi
Jean Luc Fellahi
PHPatrick B. Hu
Patrick B. Hu
VPVincent Piriou
Vincent Piriou
EtCO2 variation has been advocated replacing cardiac output measurements to evaluate fluid responsiveness (FR) during sepsis. The ability of EtCO2 variation after a fluid challenge to detect FR in the context of general anaesthesia has not been investigated. Forty patients were prospectively studied. They underwent general anaesthesia for major surgeries. CO was measured by transoesophageal Doppler, and EtCO2 was recorded as well as other haemodynamic parameters [heart rate (HR), mean arterial pressure (MAP), pulse pressure (PP)] at baseline, after 100-ml fluid load over 1 min, and at the end of the 500-ml fluid load. We measured the variation of EtCO2 at 100 (ΔEtCO2100) and 500 ml (ΔEtCO2500), and ROC curves were generated. A threshold for ΔEtCO2 to predict FR was determined with receiver operating curves (ROC) analysis. The primary end point was the ability of EtCO2 variation after a 500-ml fluid load to diagnose FR. Fifteen patients (38 %) were fluid responders. ROC analysis showed that for a threshold of 5.8 % (ΔEtCO2500), sensitivity was 0.6 IC 95 % [0.33; 0.86] and specificity was 1.0 IC 95 % [1.0; 1.0]. An absolute increase of more than 2 mmHg of EtCO2 is specific to diagnose fluid responsiveness (spe = 96 [88–100] %, sens = 60 [33–88] %, AUC = 0.80 [0.96–0.65]). HR, MAP, and PP variations and ΔEtCO2100 did not bring information to predict or diagnose FR. During fluid challenge, the correlation between CI variation and EtCO2 variation was r = 0.566, p < 0.001. During surgery, when alveolar ventilation and CO2 production are constant, ΔEtCO2500 is fairly reliable to assess FR. When the variation of EtCO2 is >5.8 %, all patients were responders, but no conclusion could be done when this variation was <5.8 %. ΔEtCO2100 failed to predict FR. Trial registration CPP Lyon Sud Est III ref: 2013-027 B, Number ID RCB: 2013-A00729-36 delivered by the ANSM).