Mario Alejandro Fabiani

Dr. Mario Alejandro Fabiani


Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2022 in World Journal of Surgery
Verified
Journal Article
Closed access
PDF file
MGMauricio Gonzalez‐Urquijo
Mauricio Gonzalez‐Urquijo
VVVictor Hugo Viteri‐Pérez
Victor Hugo Viteri‐Pérez
ABAndrea Becerril‐Gaitan
Andrea Becerril‐Gaitan
DHDavid Hinojosa‐Gonzalez
David Hinojosa‐Gonzalez
MEMaría Elizabeth Enríquez‐Vega
María Elizabeth Enríquez‐Vega
JBJosé Ángel Barajas‐Colón
José Ángel Barajas‐Colón

15 July 2022 in Head & Neck
Verified
Journal Article
Closed access
MGMauricio Gonzalez‐Urquijo
Mauricio Gonzalez‐Urquijo
ACAlejandra Castro‐Varela
Alejandra Castro‐Varela
ABAlanna Barrios‐Ruiz
Alanna Barrios‐Ruiz
DHDavid Hinojosa
David Hinojosa
ASAna Karen Garza Salas
Ana Karen Garza Salas
MFMario Alejandro Fabiani
Mario Alejandro Fabiani

16 August 2021 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PDF file
DHDavid Hinojosa
David Hinojosa
GSGustavo Salgado-Garza
Gustavo Salgado-Garza
MTMauricio Torres-Martinez
Mauricio Torres-Martinez
SLSergio Uriel Villegas-De Leon
Sergio Uriel Villegas-De Leon
LBLuis Carlos Bueno-Gutierrez
Luis Carlos Bueno-Gutierrez
EFEduardo Flores-Villalba
Eduardo Flores-Villalba
Endovascular treatment through either percutaneous transluminal angioplasty (PTA) alone or stenting has been previously used as a treatment for transplant renal artery stenosis (TRAS). This review aimed to investigate the results of endovascular treatment for renal artery stenosis in transplanted kidneys as compared with the outcomes of interventions, medical management, and graft survival in non-TRAS patients. A systematic review of PubMed, Google Scholar, Cochrane, and Scopus was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines in which studies that reported outcomes of the treatment of TRAS via the endoluminal approach were identified, and their results were meta-analyzed. Fifty-four studies with a total of 1522 patients were included. A significant reduction of serum creatinine level was found, favoring the stenting group, with a mean difference of 0.68 mg/dL (95% confidence interval (CI), 0.17–1.19; Z=2.60, p=0.0009). Comparison of pre- and post-intervention values of any intervention revealed a significant decrease in overall serum creatinine level (0.65 mg/dL; 95% CI, 0.40–0.90; Z=5.09, p=0.00001), overall blood pressure, with a mean difference of 11.12 mmHg (95% CI, 7.29–14.95; Z=5.59, p=0.00001), mean difference in the use of medications (0.77; 95% CI, 0.29–1.24; p=0.002), and peak systolic velocity (190.05; 95% CI, 128.41–251.69; p<0.00001). The comparison of serum creatinine level between endovascular interventions and best medical therapy favored endovascular intervention, with a mean difference of 0.23 mg/dL (95% CI, 0.14–0.32; Z=5.07, p<0.00001). Graft survival was similar between the treated patients and those without TRAS (hazard ratio, 0.98; 95% CI, 0.75–1.28; p=0.091). The overall pooled success rate was 89%, and the overall complication rate was 10.4%, with the most prevalent complication being arterial dissection. The endovascular treatment of TRAS improves graft preservation and renal function and hemodynamic parameters. PTA + stenting appears to be a more effective option to PTA alone in the stabilization of renal function, with additional benefits from decreased restenosis rates. Further high-quality studies could expand on these findings.

27 April 2021 in Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
PDF file
MGMauricio Gonzalez-Urquijo
Mauricio Gonzalez-Urquijo
RZRaul Garza de Zamacona
Raul Garza de Zamacona
AMAna Karen Martinez Mendoza
Ana Karen Martinez Mendoza
MIMiranda Zamora Iribarren
Miranda Zamora Iribarren
EIErika Garza Ibarra
Erika Garza Ibarra
MFMario Alejandro Fabiani
Mario Alejandro Fabiani
Background: Besides biological factors, abdominal aortic aneurysm rupture is also caused by mechanical parameters, which are constantly affecting the wall’s tissue due to their abnormal values. The ability to evaluate these parameters could vastly improve the clinical treatment of patients with abdominal aortic aneurysms. The objective of this study was to develop and demonstrate a methodology to analyze the fluid dynamics that cause the wall stress distribution in abdominal aortic aneurysms, using accurate 3D geometry and a realistic, nonlinear, elastic biomechanical model using a computer-aided software. Methods: The geometry of the abdominal aortic aneurysm; was constructed on a 3D scale using computer-aided software SolidWorks (Dassault Systems SolidWorksCorp., Waltham MA). Due to the complex nature of the abdominal aortic aneurysm geometry, the physiological forces and constraints acting on the abdominal aortic aneurysm wall were measured by using a simulation setup using boundary conditions and initial conditions for different studies such as finite element analysis or computational fluid dynamics. Results: The flow pattern showed an increase velocity at the angular neck, followed by a stagnated flow inside the aneurysm sack. Furthermore, the wall shear stress analysis showed to focalized points of higher stress, the top and bottom of the aneurysm sack, where the flow collides against the wall. An increase of the viscosity showed no significant velocity changed but results in a slight increase in overall pressure and wall shear stress. Conclusions: Conducting computational fluid dynamics modeling of the abdominal aortic aneurysm using computer-aided software SolidWorks (Dassault Systems SolidWorksCorp., Waltham MA) proves to be an insightful approach for the clinical setting. The careful consideration of the biomechanics of the abdominal aortic aneurysm may lead to an improved, case-specific prediction of the abdominal aortic aneurysm rupture potential, which could significantly improve the clinical management of these patients.

14 January 2023 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
MGMauricio Gonzalez-Urquijo
Mauricio Gonzalez-Urquijo
DHDavid Hinojosa
David Hinojosa
VVVictor Hugo Viteri-Pérez
Victor Hugo Viteri-Pérez
ALAlejandro Llausas-Villarreal
Alejandro Llausas-Villarreal
ABAndrea Becerril-Gaitan
Andrea Becerril-Gaitan
JBJosé Ángel Barajas-Colón
José Ángel Barajas-Colón

8 January 2024 in Macromolecular Rapid Communications
Verified
Journal Article
Open access
EHElnaz Hosseinzadeh
Elnaz Hosseinzadeh
BBBeatriz Bosques‐Palomo
Beatriz Bosques‐Palomo
FCFrancisco Carmona‐Arriaga
Francisco Carmona‐Arriaga
MFMario Alejandro Fabiani
Mario Alejandro Fabiani
AAAlan Aguirre‐Soto
Alan Aguirre‐Soto
An ideal vascular phantom should be anatomically accurate, have mechanical properties as close as possible to the tissue, and be sufficiently transparent for ease of visualization. However, materials that enable the convergence of these characteristics have remained elusive. The fabrication of patient‐specific vascular phantoms with high anatomical fidelity, optical transparency, and mechanical properties close to those of vascular tissue is reported. These final properties are achieved by 3D printing patient‐specific vascular models with commercial elastomeric acrylic‐based resins before coating them with thiol‐based photopolymerizable resins. Ternary thiol‐ene‐acrylate chemistry is found optimal. A PETMP/allyl glycerol ether (AGE)/polyethylene glycol diacrylate (PEGDA) coating with a 30/70% AGE/PEGDA ratio applied on a flexible resin yielded elastic modulus, UTS, and elongation of 3.41 MPa, 1.76 MPa, and 63.2%, respectively, in range with the human aortic wall. The PETMP/AGE/PEGDA coating doubled the optical transmission from 40% to 80%, approaching 88% of the benchmark silicone‐based elastomer. Higher transparency correlates with a decrease in surface roughness from 2000 to 90 nm after coating. Coated 3D‐printed anatomical replicas are showcased for pre‐procedural planning and medical training with good radio‐opacity and echogenicity. Thiol‐click chemistry coatings, as a surface treatment for elastomeric stereolithographic 3D‐printed objects, address inherent limitations of photopolymer‐based additive manufacturing.