Hongxi WANG

Dr. Hongxi WANG


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in AIP Advances
Verified
Journal Article
Open access
PDF file
PBPan Bai
Pan Bai
SWSi jiao Wang
Si jiao Wang
JJJian-Jun Jia
Jian-Jun Jia
HWHongxi WANG
Hongxi WANG
WYWei Yang
Wei Yang
With the increasing application of barium titanate (BaTiO3) in polyvinylidene fluoride (PVDF), the evaluation of its dielectric properties has attracted the attention of many frontier scholars. In this paper, from the theoretical point of view, the effects of the aspect ratio and the concentrations of BaTiO3 nanowires on macroscopic dielectric properties were studied by the finite element method. Depending on the calculation results, some conclusions had been obtained: First, it was found that the effect of higher aspect ratios of nanowires on the effective permittivity of the composites was not significant when the aspect ratio of the nanowire filler exceeded 20. Second, when the permittivity of the BaTiO3 nanowires reaches about 3000, as the permittivity of the filler increases, the rate of change of the effective permittivity of the composite material gradually slows down, which indicates that nanowires with higher permittivity have little influence on the effective permittivity of the composites. Finally, by comparing with permittivity data of BT/PVDF composites in the literature, it was found that the simulation results have good consistency with the experimentally measured values. The above-mentioned results have shown that the composite may exhibit good dielectric properties at a low concentration (<30 vol. %) and low permittivity filler. Moreover, the electrostatic field can roughly represent the electric field of a low-concentration composite under a certain electric field strength.

Verified
Journal Article
Open access
PDF file
PWPengbo Wang
Pengbo Wang
HWHongxi WANG
Hongxi WANG
HZHeming Zhang
Heming Zhang
In the field of cognitive workload assessment for aerospace training, existing methods exhibit significant limitations in unimodal feature extraction and in leveraging complementary synergy among multimodal signals, while current fusion paradigms struggle to effectively capture nonlinear dynamic coupling characteristics across modalities. This study proposes DST-Net (Cross-Modal Downsampling Transformer Network), which synergistically integrates pilots’ multimodal physiological signals (electromyography, electrooculography, electrodermal activity) with flight dynamics data through an Anti-Aliasing and Average Pooling LSTM (AAL-LSTM) data fusion strategy combined with cross-modal attention mechanisms. Evaluation on the “CogPilot” dataset for flight task difficulty prediction demonstrates that AAL-LSTM achieves substantial performance improvements over existing approaches (AUC = 0.97, F1 Score = 94.55). Given the dataset’s frequent sensor data missingness, the study further enhances simulated flight experiments. By incorporating eye-tracking features via cross-modal attention mechanisms, the upgraded DST-Net framework achieves even higher performance (AUC = 0.998, F1 Score = 97.95) and reduces the root mean square error (RMSE) of cumulative flight error prediction to 1750. These advancements provide critical support for safety-critical aviation training systems.

11 December 2019 in Journal of Applied Mechanics
Verified
Journal Article
Closed access
PDF file
JZJian Zhao
Jian Zhao
JZJian Zhang
Jian Zhang
Kon-Well WangKon-Well Wang
Kon-Well Wang
KCKai Cheng
Kai Cheng
HWHongxi WANG
Hongxi WANG
PLPengbo Liu
Pengbo Liu

4 November 2019 in Journal of Applied Mechanics
Verified
Journal Article
Closed access
PDF file
JZJian Zhao
Jian Zhao
MLMing Lyu
Ming Lyu
HWHongxi WANG
Hongxi WANG
Najib KacemNajib Kacem
Najib Kacem
YHYu Huang
Yu Huang
PLPengbo Liu
Pengbo Liu

16 September 2022 in Metrology and Measurement Systems
Verified
Journal Article
Open access
PDF file
WCWen-Meng Chen
Wen-Meng Chen
HWHongxi WANG
Hongxi WANG
GWGuan-Wei Wang
Guan-Wei Wang
WLWen-Hong Liang
Wen-Hong Liang
Accurate and fast access to Vernier caliper readings is a critical issue in automated verification of Vernier calipers. To address this problem, this paper proposes a machine vision-based algorithm for reading the Vernier caliper's displayed value. The suggested method first employs threshold segmentation and template matching to determine the region of interest and obtain the main ruler digit position by alternate projection. Then, we apply the improved LeNet5 network to identify the main ruler of the Vernier caliper, Moreover, we developed the first and last inscription method for reading the decimal part of the Vernier caliper and established our data set for model training. Extensive experiments on reading the displayed value have demonstrated our algorithm's accuracy, which achieves a displayed value reading accuracy of 100%. Compared to other methods, the proposed technique affords better stability and accuracy.

1 April 2023 in Measurement Science Review
Verified
Journal Article
Open access
PDF file
MXMeng-Ting Xu
Meng-Ting Xu
HWHongxi WANG
Hongxi WANG
YWYa-Xiao Wang
Ya-Xiao Wang
HTHui-Hui Tian
Hui-Hui Tian
The Crankshaft Full-automatic Measuring Machine (CFMM) features high accuracy, high efficiency and complete measurement parameters, and represents the forefront of a geometric crankshaft accuracy measuring instrument. One of its core technologies is the high-precision radial following the crankshaft connecting rod journal measurement. In this paper, an independent probe design scheme combining the flexible dual-complex parallel four-bar guide mechanism and double displacement sensors based on the contact measurement method was proposed. It was suitable for the measurement of precision parts with eccentric characteristics such as crankshaft and camshaft measurement. Taking the spring as the flexible part, the probe prototype’s optimization design, processing and assembly were completed, the test device was built, and the system accuracy was calibrated under various positions and feed quantities of the probe. The results revealed that the expanded measurement uncertainty after double-sensor compensation was enhanced from 1.53 μm in single-sensor measurement to 0.44 μm, satisfying the high-precision requirements of engineering measurement accuracy and reducing the measurement cost.