Background: The present study evaluated the relationship between body-roundness index (BRI) and metabolic syndrome (MetS) in type 2 diabetes. Methods: A cross-sectional study was conducted on 585 type 2 diabetes in Qinhuangdao. MetS was defined as per the Chinese Diabetes Society. Results: The BRI was strongly associated with the odds of having MetS in both males and females after adjustment for age, history of diabetes, and body-mass index (P<0.05). AUC of the BRI were 0.824 for males and 0.775 for females (P<0.001). The optimal cutoff points for the BRI were 3.85 in males (sensitivity 76.5%, specificity 82.1%) and 4.05 in females (sensitivity 76.4%, specificity 70.3%). Conclusion: The BRI was correlated with MetS and was an effective indicator for the screening of MetS in type 2 diabetes.
The present study evaluated the performance of three novel obese indicators, visceral adiposity index (VAI), lipid accumulation product (LAP) and waist circumference-triglyceride index (WTI), for identifying metabolic syndrome(MetS) in type 2 diabetes. A cross-sectional study was conducted on 711 type 2 diabetes in Qinhuangdao. The MetS was defined as the definition of Chinese Diabetes Society. Receiver operating characteristic curve analyses were performed to assess the accuracy of three obese indicators as diagnostic tests for MetS. The prevalence of MetS was 71.3%. In men, among all three obese indicators, the LAP had the highest area under curve (AUC) value (AUC = 0.894), followed by VAI (AUC = 0.860) and WTI (AUC = 0.855). In women, among all three obese indicators, the LAP had the highest AUC value (AUC = 0.906), followed by WTI (AUC = 0.887) and VAI (AUC = 0.881). However. there was no significant difference between the three obese indicators(P > 0.05). Three obese indicators were effective indicators for the screening of MetS, LAP and WTI are more simple.
The present study evaluated the performance of 2 novel adiposity indicators, body shape index (ABSI), and body roundness index (BRI), to determine the accumulation of visceral fat in type 2 diabetic patients. A cross-sectional study was performed on 233 type 2 diabetic patients from Qinhuangdao, China. Visceral fat area (VFA) was measured using bioelectrical impedance. Accumulation of visceral fat was defined as VFA ≥ 100 cm2. In diabetic males, the area under the curve (AUC) values were 0.904 for waist circumference (WC), 0.923 for BRI, and 0.788 for ABSI. In diabetic females, the AUC values were 0.894 for WC, 0.915 for BRI, and 0.668 for ABSI. The AUCs were similar between BRI and WC (P > .05). The AUC for ABSI was lower compared to WC and BRI (P < .05). The optimal cut-off for BRI was 4.25 for diabetic males (sensitivity = 87.8% and specificity = 81.1%) and 4.75 for diabetic females (sensitivity = 80.8% and specificity = 88.1%). BRI was an effective indicator for determining the accumulation of visceral fat in type 2 diabetic patients, however, it was not better compared to WC.