This work develops a thorough review of bioimpedance systems for healthcare applications. The basis and fundamentals of bioimpedance measurements are described covering issues ranging from the hardware diagrams to the configurations and designs of the electrodes and from the mathematical models that describe the frequency behavior of the bioimpedance to the sources of noise and artifacts. Bioimpedance applications such as body composition assessment, impedance cardiography (ICG), transthoracic impedance pneumography, electrical impedance tomography (EIT), and skin conductance are described and analyzed. A breakdown of recent advances and future challenges of bioimpedance is also performed, addressing topics such as transducers for biosensors and Lab-on-Chip technology, measurements in implantable systems, characterization of new parameters and substances, and novel bioimpedance applications.
15 January 2015 in IEEE Transactions on Microwave Theory and Techniques
A simple and flexible technique for improving the modeling and predistortion of power amplifiers is presented. The technique, which relies on the sparsity assumption for the kernel coefficients of the full Volterra (FV) behavioral model, combines a greedy algorithm for the selection of the active coefficients, a maximum likelihood method for their estimation and an information criterion for determining the best model. The approach has been applied to the design of reduced-parameters FV-based digital predistorters for three power amplifiers driven with orthogonal frequency division multiplexing signals, following the LTE and DVB-T2 standards, and a multichannel wideband code-division multiple access signal. Results show that the proposed linearizers meet the spectral masks and error vector magnitude constraints of the referred standards and provide a reduction better than 45% in the number of parameters, compared to the FV predistorters.
15 May 2013 in IEEE Transactions on Instrumentation and Measurement
One of the main objectives of research into intrabody communication (IBC) is the characterization of the human body as a transmission medium for electrical signals. However, such characterization is strongly influenced by the conditions under which the experiments are performed. In addition, the outcomes reported in the literature vary according to the measurement method used, frequently making comparisons among them unfeasible. Further studies are still required in order to establish a methodology for IBC characterization and design. In this paper, both galvanic and capacitive coupling setups have been implemented and a comprehensive set of measurements has been carried out by analyzing fundamental IBC parameters such as optimum frequency range, maximum channel length, and type of electrodes, among others. Consequently, practical conclusions regarding the experimental conditions that optimize IBC performance for each coupling technique have been obtained.
1 November 2012 in IEEE Transactions on Biomedical Engineering
Modeling of intrabody communication (IBC) entails the understanding of the interaction between electromagnetic fields and living tissues. At the same time, an accurate model can provide practical hints toward the deployment of an efficient and secure communication channel for body sensor networks. In the literature, two main IBC coupling techniques have been proposed: galvanic and capacitive coupling. Nevertheless, models that are able to emulate both coupling approaches have not been reported so far. In this paper, a simple model based on a distributed parameter structure with the flexibility to adapt to both galvanic and capacitive coupling has been proposed. In addition, experimental results for both coupling methods were acquired by means of two harmonized measurement setups. The model simulations have been subsequently compared with the experimental data, not only to show their validity but also to revise the practical frequency operation range for both techniques. Finally, the model, along with the experimental results, has also allowed us to provide some practical rules to optimally tackle IBC design.
25 June 2018 in IEEE Microwave and Wireless Components Letters
This letter presents a new method for the digital predistortion (DPD) of power amplifiers (PAs) based on sparse behavioral models. The Gram-Schmidt orthogonalization is synergistically integrated into the orthogonal matching pursuit algorithm to decorrelate the selected model regressors against the components still to be selected. Experiments on a test bench based on a GaN PA driven by a 15-MHz orthogonal frequency division multiplexing signal were conducted in order to validate the algorithm. Experimental results in a DPD application and a comparison with other state-of-the-art algorithms highlight the enhancement of its pruning capabilities, reducing the number of coefficients while maintaining the performance.
In this paper, a first approach to the design of a portable device for non-contact monitoring of respiratory rate by capacitive sensing is presented. The sensing system is integrated into a smart vest for an untethered, low-cost and comfortable breathing monitoring of Chronic Obstructive Pulmonary Disease (COPD) patients during the rest period between respiratory rehabilitation exercises at home. To provide an extensible solution to the remote monitoring using this sensor and other devices, the design and preliminary development of an e-Health platform based on the Internet of Medical Things (IoMT) paradigm is also presented. In order to validate the proposed solution, two quasi-experimental studies have been developed, comparing the estimations with respect to the golden standard. In a first study with healthy subjects, the mean value of the respiratory rate error, the standard deviation of the error and the correlation coefficient were 0.01 breaths per minute (bpm), 0.97 bpm and 0.995 (p < 0.00001), respectively. In a second study with COPD patients, the values were −0.14 bpm, 0.28 bpm and 0.9988 (p < 0.0000001), respectively. The results for the rest period show the technical and functional feasibility of the prototype and serve as a preliminary validation of the device for respiratory rate monitoring of patients with COPD.