Hongyan Guo

Prof. Dr. Hongyan Guo


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
PCPing Chen
Ping Chen
AZAiwu Zhao
Aiwu Zhao
JWJin Wang
Jin Wang
QHQinye He
Qinye He
HSHenghui Sun
Henghui Sun
HGHongyan Guo
Hongyan Guo

26 February 2023 in Molecules
Verified
Journal Article
Open access
PDF file
HLHui Liu
Hui Liu
YZYuanyuan Zhao
Yuanyuan Zhao
LCLeijing Chen
Leijing Chen
JDJiao Du
Jiao Du
HGHongyan Guo
Hongyan Guo
BWBin Wang
Bin Wang
Traditional Chinese medicine (TCM) safety and effectiveness can be ensured by establishing a suitable quality assessment system. This work aims to develop a pre-column derivatization HPLC method for Polygonatum cyrtonema Hua. quality control. In this study, 1-(4′-cyanophenyl)-3-methyl-5-pyrazolone (CPMP) was synthesized and reacted with monosaccharides derived from P. cyrtonema polysaccharides (PCPs), followed by HPLC separation. According to the Lambert–Beer law, CPMP has the highest molar extinction coefficient of all synthetic chemosensors. A satisfactory separation effect was obtained under a detection wavelength of 278 nm using a carbon-8 column and gradient elution over 14 min, with a flow rate of 1 mL per minute. Glucose (Glc), galactose (Gal), and mannose (Man) make up the majority of the monosaccharide components in PCPs, and their molar ratios are 1.73:0.58:1. The confirmed HPLC method has outstanding precision and accuracy, establishing a quality control method for PCPs. Additionally, the CPMP showed a visual improvement from colorless to orange after the detection of reducing sugars, allowing for further visual analysis.

15 February 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
JZJunqing Zhang
Junqing Zhang
RWRujing Wang
Rujing Wang
ZJZhou Jin
Zhou Jin
HGHongyan Guo
Hongyan Guo
YLYi Liu
Yi Liu
XCXiangyu Chen
Xiangyu Chen
The acquisition of nutrient data on a precise scale has played a vital role in nutrient management processes for soils. However, the lack of rapid precise and multi-index detection techniques for soil macronutrient contents hinders both rational fertilization and cost reduction. In this paper, a rapid detection method and device were devised, combining capillary electrophoresis (CE) and capacitively coupled contactless conductivity detection (C4D), and presented to detect macronutrient contents of soil. The device consisted of a capillary channel, C4D detector, high-voltage system, etc. It separated macronutrient ions using capillary electrophoresis and then measured the ion concentration based on the C4D principle. Lime concretion black soil samples from a complete field were collected and detected. NO3−, NH4+, H2PO4− and K+ in sample solutions could be detected in 5 min with relative standard deviations (RSDs) from 1.0 to 7.51%. The injection voltage was set to 10 kV for 5 s, and the separation voltage was set to 14 kV. This demonstrated the excellent performance of the C4D device on the detection of soil macronutrients, which could help to guide fertilization operations more effectively.

28 January 2023 in Agriculture
Verified
Journal Article
Open access
PDF file
YWYuanyuan Wei
Yuanyuan Wei
RWRujing Wang
Rujing Wang
JZJunqing Zhang
Junqing Zhang
HGHongyan Guo
Hongyan Guo
XCXiangyu Chen
Xiangyu Chen
A method based on capacitively coupled contactless conductivity detection (C4D), which has been proven effective for the rapid detection of available soil potassium content, was firstly proposed to apply to soil nutrient detection. By combining a detection signal spectrum analysis, geographic information system (GIS) data, and a cluster analysis, a soil nutrient management system to match the detection device was developed. This system included six modules: soil sample information management, electrophoresis analysis, quantitative calculation, nutrient result viewing, cluster analysis, and nutrient distribution map generation. The soil samples, which were collected from an experimental field in Xuchang City of Henan Province, were analyzed using the C4D and flame photometer methods. The results showed that the detection results for the soil samples obtained via the two methods were in good agreement. C4D technology was feasible for the detection of the soil available nutrients and had the advantages of a high timeliness, low sample volume, and low pollution. The soil nutrient management system adopted the hierarchical clustering method to classify the grid cells of the experimental field according to the nutrient detection results. A soil nutrient distribution map displayed the spatial difference in nutrients. This paper provides a systematic solution for soil nutrient zone management that includes nutrient detection, signal analysis, data management for the nutrient zone, and field nutrient distribution map generation to support decision making in variable fertilization.

13 March 2026 in Journal of Nanoparticle Research
Verified
Journal Article
Closed access
PDF file
XZXu Zhao
Xu Zhao
HGHongyan Guo
Hongyan Guo
NZNannan Zhang
Nannan Zhang
ZYZhi Yue
Zhi Yue
XGXungang Gu
Xungang Gu

12 May 2026 in Agriculture
Verified
Journal Article
Open access
PDF file
YHYan Hong
Yan Hong
BZBiquan Zhu
Biquan Zhu
JSJingming Su
Jingming Su
QCQiao Cao
Qiao Cao
JSJunjie Song
Junjie Song
XCXiangyu Chen
Xiangyu Chen
Soil moisture monitoring is critical to agricultural production and water resource management, yet existing sensors often exhibit limitations in accuracy, cost-effectiveness, and long-term stability. This study aimed to develop a high-performance capacitive soil moisture sensor to address these issues. We selected eco-friendly lead-free K2CuBr3 as the hygroscopic material and optimized the interdigital electrode (IE) structure via theoretical analysis and finite element simulation. The sensors were fabricated using micro-electro-mechanical system (MEMS) technology, and their performance was systematically evaluated with real soil samples. The results demonstrated that K2CuBr3 substantially enhanced the sensor sensitivity. The optimal sensor exhibited a measurement error of approximately 5% over the soil moisture range of 0–42.5%, a relative standard deviation (RSD) of less than 2%, and good stability. This low-cost, lead-free MEMS capacitive sensor, based on K2CuBr3, offers high accuracy and excellent stability. It resolves key drawbacks of traditional sensors and offers a reliable solution for in situ real-time soil moisture monitoring, with broad prospects in smart agriculture.