Xiang Shen

Prof. Xiang Shen

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2019 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
XSXiang Shen
Xiang Shen
HZHongfei Zhu
Hongfei Zhu
JJJiabao Jiang
Jiabao Jiang
YDYongquan Deng
Yongquan Deng
SJSong Ji
Song Ji

2 August 2018 in Journal of Mechanics
Verified
Journal Article
Open access
PDF file
XSXiang Shen
Xiang Shen
YDY. Q. Deng
Y. Q. Deng
SJS. Ji
S. Ji
HZH. F. Zhu
H. F. Zhu
JJJ. B. Jiang
J. B. Jiang
LGL. X. Gu
L. X. Gu
Vessel flexure can be triggered naturally by surgical operation, heart pulsation and body movement. It may affect the mechanical behavior of the stent and the existence of a stent may in turn cause vessel injury. In the present study, the finite element method is employed to study the interaction between stent and vessel during vessel flexure. Two- and four-link stents made of stainless steel 316L and magnesium alloy WE43 are considered. Results indicate that longitudinal deformation of the stent can be caused by vessel flexure, and the higher levels of stress exist in the link struts. The existence of the stent could induce significant stress concentration and straightened deformation on vessel wall in the course of vessel flexure. Stents with more links or made of harder materials show greater anti-deformation capability, thus inducing a more severe stress concentration and straightened deformation on the vessel wall. The bending direction also affects the mechanical performance of the vessel-stent system. The results obtained could provide useful information for better stent designs and clinical decisions.

14 December 2014 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Closed access
XSXiang Shen
Xiang Shen
ZXZhong-Min Xie
Zhong-Min Xie
Yangyang SunYangyang Sun
Yangyang Sun
BWBo-Bo Wu
Bo-Bo Wu

30 April 2020 in Journal of Mechanics
Verified
Journal Article
Closed access
PDF file
XSXiang Shen
Xiang Shen
JJJ. B. Jiang
J. B. Jiang
HZH. F. Zhu
H. F. Zhu
YDY. Q. Deng
Y. Q. Deng
SJS. Ji
S. Ji
Flexibility is one of the important mechanical performance parameters of stent. The flexibility of tapered stents, especially self-expanding tapered stents, remains unknown. In this study, we developed a new selfexpanding tapered stent for tapered arteries and performed a numerical investigation of stent flexibility by using finite element method. The effect of stent design parameters, including taper and link space width, on stent flexibility was studied. The flexibility of the proposed stent was also compared with that of traditional cylindrical stents. Results show that the tapered stent is more flexible than the traditional cylindrical stent. Furthermore, the flexibility of the tapered stent increases with increasing stent taper and stent link space width. The increase in the stent link space width can contribute to the reduction in the peak stress. Therefore, tapered stents with high link space width will improve the stent flexibility. This work provides useful information for improvement of stent design and clinical selection.

1 March 2020 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
XSXiang Shen
Xiang Shen
JJJiabao Jiang
Jiabao Jiang
HZHongfei Zhu
Hongfei Zhu
KLKaikai Lu
Kaikai Lu
PDPengfei Dong
Pengfei Dong
LGLinxia Gu
Linxia Gu

5 July 2019 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
PDF file
XSXiang Shen
Xiang Shen
HZHongfei Zhu
Hongfei Zhu
SJSong Ji
Song Ji
JJJiabao Jiang
Jiabao Jiang
YDYongquan Deng
Yongquan Deng
Stenting has achieved great success in treating cardiovascular diseases due to its high efficiency and minimal invasiveness. However, fatigue of stents severely limits its long-term outcome. In this article, finite element method was adopted to study the effects of arterial tapering and stent material on the fatigue performance of stents. A series of tapered vessels with different taper levels and two sets of stents with different materials were modeled. The Goodman diagram was used to evaluate the fatigue resistance of stents. Results showed that the fatigue resistance of stents can be extremely improved by simply changing stent material. In addition, the taper of the arteries had an important influence on the fatigue resistance of the stent. The fatigue life of the stent will be shortened with the increase of the arterial taper. The method that predicted stent fatigue life in tapered vessels can help clinicians select stents that are more suitable for tapered vessels and help stent engineers design stents that are more resistant to fatigue.