Shiv Verma

Mr. Shiv Verma


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ARAsama Rana
Asama Rana
IHIrbaz Hameed
Irbaz Hameed
SDSedem Dankwa
Sedem Dankwa
DADanial Ahmad
Danial Ahmad
CBCameron Best
Cameron Best
PVPrashanth Vallabhajosyula
Prashanth Vallabhajosyula
Objectives: Several measurement techniques have been proposed to address the non-circular geometry of the aortic root. The Laplace diameter metric incorporates the cloverleaf anatomy of the aortic root and is derived via measurement of sinus-to-commissure lengths with subsequent doubling of the largest radius from the center. This study compares the conventional sinus-to-sinus with the novel Laplace method for sizing the aortic root and quantifying its implication on surgical decision-making. Methods: Patients undergoing surveillance at a high-volume aortic center were categorized by aortic root morphology as nondilated, non-syndromic dilated, bicuspid aortic valve and Marfan syndrome. Aortic root diameters by sinus-to-sinus and Laplace diameter methods were measured on computed tomography, compared using paired t-tests, and correlated using Spearman rank coefficients. Results: Of the 1297 patients assessed, 530 were included in the final analysis (nondilated n = 113, non-syndromic dilated n = 347, bicuspid aortic valve n = 50, Marfan syndrome n = 17). Aortic root diameters were significantly larger by Laplace than sinus-to-sinus diameter across all groups (sinus-to-sinus: 1.9 ± 5.5 mm; Laplace: 44.9 ± 7.0 mm; 95% confidence interval 2.72–3.34; p < 0.0001). Although Laplace and sinus-to-sinus diameter were correlated (Spearman r = 0.6789, 95% CI 0.6–0.7; p < 0.0001), the relationship was non-linear (R2 = 0.492). Laplace diameter increased the proportion of patients meeting surgical thresholds (2022 AHA/ACC guidelines) versus sinus-to-sinus: nondilated 0% vs. 1.77%, non-syndromic dilated 4.9% vs. 25.1%, bicuspid aortic valve 10.0% vs. 26.0%, and Marfan syndrome 23.5% vs. 52.9%. Conclusions: On average, Laplace diameter exceeded sinus-to-sinus diameter by 3 mm and would extend surgical eligibility to an additional 21% of patients under current guidelines.

30 April 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SDSedem Dankwa
Sedem Dankwa
EEEly Erez
Ely Erez
AHAdrian Acuna Higaki
Adrian Acuna Higaki
SVShiv Verma
Shiv Verma
IHIrbaz Hameed
Irbaz Hameed
PVPrashanth Vallabhajosyula
Prashanth Vallabhajosyula
Background: In 2020, the first pre-assembled bioprosthetic aortic valved conduit (AVC) was approved in the United States. This study compares its anatomic and functional outcomes to traditional hand-sewn composite conduits in patients undergoing aortic root replacement. Methods: This retrospective study compared 118 patients receiving the pre-assembled AVC (2021–2023) versus 66 patients with hand-sewn conduits (2012–2020) after elective bio-Bentall procedures. Primary outcomes were post-operative mortality and complication rates. Secondary outcomes included anatomic and hemodynamic changes. Graft dimensions were obtained from post-operative computed tomography (CT). Echocardiographic parameters were collected at early and late follow-up. Between-group differences and longitudinal changes were assessed using linear mixed-effects models. Results: Groups were comparable in age (pre-assembled 63 ± 11 vs. hand-sewn 64 ± 11 years) and predominantly male. Despite significantly higher concomitant hemiarch rates in pre-assembled conduits (91.5% vs. 28.8%, p < 0.001), 30-day mortality, stroke, and reoperation for bleeding were comparable between groups. Pre-assembled conduits demonstrated superior hemodynamics with lower baseline peak gradients (Δ 9.1 mmHg, p < 0.001), lower mean gradients (Δ 5.3 mmHg, p < 0.001), and larger indexed effective orifice area (Δ 0.27 cm2/m2, p = 0.018). Annual rates of hemodynamic and dimensional change were minimal and comparable between groups. Kaplan–Meier analysis showed no survival difference at 3 years. Conclusions: The pre-assembled AVC demonstrates equivalent safety and superior early hemodynamic performance compared to hand-sewn conduits, with stable mid-term anatomic and functional outcomes.