Objectives: Lung organ scarcity has led to more generous acceptance of organs under the idea of extended-donor criteria. However, long-term effects have to be monitored to redefine present practice. In this study, we investigated the impact of donor age over 55 years in lung transplantation. Methods: In this retrospective study, 186 consecutive double-lung transplantation procedures from January 2000 to December 2008 were evaluated. A total of 19 recipients received lungs from donors aged 55 years or older (range 55–69 years) (group A) and 167 received lungs from younger donors (range 8–54) (group B). In-hospital mortality, intensive care unit (ICU) stay, rejection episodes, lung function and survival up to 5 years were evaluated. Results: In-hospital mortality was similar in both groups (group A: 10.5%; group B: 13.7%). Postoperative ICU stay was 19 ± 33 days versus 17 ± 34 days (A vs B). Rejection episodes as well as postoperative lung function up to 5 years, and overall cumulative 5-year survival (group A: 52.4%; group B: 50.9%) did not reach statistical significance. However, a trend of increased bronchiolitis obliterans syndrome (BOS) prevalence and reduced lung function was noted. Cause of death showed no differences in both groups. Conclusions: Donor age ≥55 years does not compromise immediate and long-term results after lung transplantation, although long-term observation of patients receiving such an organ suggests earlier lung dysfunction. Due to the rising need of organs, lungs from donors aged 55 or older have to be considered for transplantation. However, the acceptance should be based on donor lung evaluation and individual recipient needs. Long-term outcomes over 5 years need to be further investigated.
Background and Objectives: The understanding of high body mass index (BMI) and outcomes after Left Ventricular Assist Device (LVAD) implantation continues to evolve and the relationship has not been established yet. In this study, we investigated the effects of obesity (BMI > 30 kg/m2) on post–LVAD implantation outcomes. HeartWare LVAD and Heart Mate III LVAD were implanted. The primary outcome that was measured was mortality (in-hospital and on follow-up). The secondary outcomes that were measured were major adverse events. Materials and Methods: At our institution, the West German Heart and Vascular Center (Essen, Germany), from August 2010 to January 2020, a total of 210 patients received a long-term LVAD. Patients were stratified according to BMI ≥ 30 kg/m2 representing the obesity threshold. The first group (n = 162) had an average BMI of 24.2 kg/m2 (±2.9), and the second group (n = 48) had an average BMI of 33.9 kg/m2 (±3.2). Baseline demographics were analysed alongside comorbidities per group. Results: Overall mortality was not significantly different between the obese group (51.1% n = 24) and the nonobese group (55.2%, n = 85) (p = 0.619). The difference between the mean duration of survival of patients who expired after hospital discharge was insignificant (2.1 years ± 1.6, group 1; 2.6 years ± 1.5, group 2; p = 0.29). In-hospital mortality was unvaried between the two groups: group 1: n = 34 (44% out of overall group 1 deaths); group 2: n = 11 (45.8% out of overall group 2 deaths) (p > 0.05). Postoperative complications were unvaried between the obese and the non-obese group (all with p > 0.05). However, a significant difference was found with regards to follow-up neurological complications (18.5% vs. 37.8%, p = 0.01) and LVAD thrombosis (14.7% vs. 33.3%, p = 0.01), as both were higher in the obese population. Conclusion: Obesity does not form a barrier for LVAD implantation in terms of mortality (in-hospital and on follow up). However, a significantly higher incidence of follow-up LVAD thrombosis and neurological complications has been found in the obese group of patients.
15 November 2017 in European Journal of Medical Research
Resternotomy in cardiac surgery is considered a risk factor for postoperative complications. Previous studies have demonstrated an ambiguous relationship between resternotomy and clinical outcomes. Registry data from a mixed population of durable circulatory support devices suggest that history of cardiac surgery is a risk factor for mortality. Our study investigates the prognostic significance of resternotomy in a homogenous cohort of left ventricular assist device (LVAD) recipients. The study included adult patients receiving a continuous-flow LVAD at our institution during the period 2010–2016. Postoperative adverse events and length of stay were analyzed. Survival was assessed at 6 months and by the end of the study. Multivariate risk factor analysis was conducted for independent predictors of death. One hundred twelve patients, who received an intrapericardial LVAD (HVAD, HeartWare), were included in our analysis. Twenty-four patients (21.4%) had a history of previous sternotomy. These patients were older and non-eligible for bridging, and had more frequently coronary heart disease. Univariate analysis demonstrated no differences in the observed complications postoperatively. Survival was similar among groups. Destination therapy was the only predictor of mortality in our analysis (p = 0.02). Resternotomy was not associated with worse outcomes after LVAD implantation in our cohort.
Organ shortage, subsequent use of extended donor criteria organs and high-risk recipients needing redo-surgery are increasing the complexity of heart transplantation. Donor organ machine perfusion (MP) is an emerging technology allowing reduction of ischemia time as well as standardized evaluation of the organ. The aim of this study was to review the introduction of MP and analyze the results of heart transplantation after MP in our center. In a retrospective single-center study, data from a prospectively collected database were analysed. From July 2018 to August 2021, fourteen hearts were retrieved and perfused using the Organ Care System (OCS), 12 hearts were transplanted. Criteria to use the OCS were based on donor/recipient characteristics. Primary objective was 30-day survival, secondary objectives were major cardiac adverse events, graft function, rejection episodes as well as overall survival in the follow-up and assessment of MP technical reliability. All patients survived the procedure and the postoperative 30-day interval. No MP related complications were noted. Graft ejection fraction beyond 14 days was ≥ 50% in all cases. Endomyocardial biopsy showed excellent results with no or mild rejection. Two donor hearts were rejected after OCS perfusion and evaluation. Ex vivo normothermic MP during organ procurement is a safe and promising technique to expand the donor pool. Reduction of cold ischemic time while providing additional donor heart assessment and reconditioning options increased the number of acceptable donor hearts. Additional clinical trials are necessary to develop guidelines regarding the application of MP.
Background and Objectives: The use of temporary left ventricular assist devices (tLVADs) for patients suffering from cardiogenic shock (CS) is becoming more common. This study examines the indications and outcomes of microaxial flow pumps (Impella®, Abiomed Inc., Danvers, MA, USA) when cannulated through the axillary artery in patients with severe CS, with a particular focus on acute phase reactions and hemolytic responses. Materials and Methods: This single-center, retrospective cohort involved patients who received microaxial Impella implantation via the axillary artery from 2020 to 2022 (n = 47). Results: Among the patients, 66% (N = 31 cases) were treated with the Impella 5.5, 25.5% (N = 12 cases) with the Impella 5.0, and 8.5% (N = 4 cases) with the Impella CP. Additionally, 28% were managed using the ECMELLA concept. The mean length of time for Impella support was 8 days. The overall 30-day survival rate was 78%, with no significant differences observed between the ECMELLA group and the various Impella types. At 30 days post-therapy, 47% of survivors no longer required mechanical support, while 26% were upgraded to a durable LVAD. Interleukin-6 (IL-6) levels were significantly lower in patients receiving Impella 5.5 (n = 17 vs. 12) immediately following implantation (p = 0.03) compared with those with smaller devices. Haptoglobin levels were significantly higher in the Impella 5.5 group (n = 17 vs. 11, p = 0.02), with overall lower rates of hemolysis (45.1%, p < 0.01). Conclusions: The mortality rate in critical CS appears reduced with axillary artery implantation of Impella devices relative to existing literature. A full-flow microaxial pump (Impella 5.5) seems advantageous regarding systemic inflammatory response syndrome (SIRS) and acute hemolysis, indicated by lower IL-6 and higher haptoglobin levels, compared with smaller Impella devices. A tailored escalation/de-escalation concept using axillary access for different mAFP types appears feasible and safe.